SANS 982-2009 High-pressure high-vacuum steam sterilizers (autoclaves)《高压高真空蒸汽灭菌器(高压锅)》.pdf
《SANS 982-2009 High-pressure high-vacuum steam sterilizers (autoclaves)《高压高真空蒸汽灭菌器(高压锅)》.pdf》由会员分享,可在线阅读,更多相关《SANS 982-2009 High-pressure high-vacuum steam sterilizers (autoclaves)《高压高真空蒸汽灭菌器(高压锅)》.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA
2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any
3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ISBN 978-0-626-23408-9 SANS 982:2009Edition 3.1Any reference to SABS 982 is deemed to be a reference to this standard (Government Notice No. 1373 of 8 No
4、vember 2002) SOUTH AFRICAN NATIONAL STANDARD High-pressure high-vacuum steam sterilizers (autoclaves) Published by SABS Standards Division 1 Dr Lategan Road Groenkloof Private Bag X191 Pretoria 0001Tel: +27 12 428 7911 Fax: +27 12 344 1568 www.sabs.co.za SABS SANS 982:2009 Edition 3.1 Table of chang
5、es Change No. Date Scope Amdt 1 2009 Amended to change the designation of SABS standards to SANS standards, to delete the reference to national legislation from the text, to update language marking requirements on operating controls, on double doors and on instruction booklets, to update referenced
6、standards, to delete a footnote regarding the obtainability of suitable autoclave indicator tape from the SABS, to update the quality verification appendix (appendix C), and to add a bibliography. Foreword This South African standard was approved by National Committee SABS TC 1048, Hospital equipmen
7、t and supplies, in accordance with procedures of the SABS Standards Division, in compliance with annex 3 of the WTO/TBT agreement This document was published in September 2009. This document supersedes SABS 982:1990 (edition 3). A reference is made in NOTE (a) to 1.1 and in a NOTE to 5.7.4 to regula
8、tions governing pressure vessels and boilers promulgated in terms of “the current relevant national legislation“. In South Africa this means the Factories, Machinery and Building Work Act, 1941 (Act No. 22 of 1941). A vertical line in the margin shows where the text has been technically modified by
9、amendment No. 1. SANS 982:2009 Edition 3.1 1 Contents Page Foreword 1 Scope 3 2 Definitions . 3 3 Types 4 4 Functional requirements . 4 5 Constructional requirements . 7 6 Electrical equipment (general) and steam generator (type B sterilizers only) . 11 7 Marking and instructions 12 8 Inspection and
10、 methods of test 13 8.1 Inspection 13 8.2 Test sequence 13 8.3 Automatic operation tests . 13 8.4 Air removal test . 14 8.5 Leak test 14 8.6 Sterility test (Bowie and Dick autoclave tape test) 14 8.7 Tests on electrical equipment (type B sterilizers only) 16 Appendix A Applicable standards . 17 Appe
11、ndix B Notes to purchasers 17 Appendix C Quality verification of sterilizers 18 Amdt 1 Bibliography . 18 Amdt 1 SANS 982:2009 Edition 3.1 2 This page is intentionally left blank SANS 982:2009 Edition 3.1 3 High-pressure high-vacuum steam sterilizers (autoclaves) 1 Scope 1.1 This specification covers
12、 functional and constructional requirements for automatic sterilizers (vacuum and steam type) that may be used in hospitals, in conjunction with an independent or a dedicated steam supply, for sterilizing unwrapped utensils, instruments, hollow ware, wrapped goods (packs), porous loads and, when so
13、required (by special modification to the sterilizer), fluids. NOTE a) The manufacture of 1) the sterilizing chamber; 2) the steam jacket of pressure-type sterilizers; and 3) the steam generator of a sterilizer having a dedicated steam supply is governed by regulations covering pressure vessels and b
14、oilers, as relevant, promulgated in terms of the current relevant national legislation (see foreword). The specification does not purport to supersede or overrule any of the requirements laid down in the Act. Amdt 1b) The standards referred to in the specification are listed in appendix A. c) Requir
15、ements that must be specified by the purchaser and information that should be sought from the supplier are given in appendix B. d) Guidance on the verification of the quality of sterilizers is given in appendix C. 2 Definitions 2.1 For the purposes of this specification the following definitions sha
16、ll apply: absolute pressure pressure measured from absolute vacuum chamber that part of the sterilizer that accommodates the items undergoing sterilization cycle the operating cycle SANS 982:2009 Edition 3.1 4 gauge pressure pressure measured from ambient atmospheric pressure high vacuum descriptive
17、 of an absolute pressure not exceeding 20 kPa 3 Types 3.1 The sterilizers shall be of the following types: Type A Sterilizers operating with steam from an independent source. Type B Sterilizers operating with steam generated in a built-in electric steam generator. 4 Functional requirements 4.1 Steam
18、 control and pressure 4.1.1 Pressure reducing valve A sterilizer shall be provided with a pressure reducing valve or an equivalent device to enable the required steam pressure in the chamber and jacket to be maintained. 4.1.2 Steam separator When the sterilizer chamber steam is not drawn from the st
19、eam jacket, a steam separator (to remove steam condensate) shall be fitted on the inlet steam side of the steam circuit before the pressure reducing valve is fitted. 4.1.3 Operating steam pressure The chamber and jacket of a sterilizer shall be capable of operating at an internal gauge pressure of a
20、t least 240 kPa. 4.2 Air removal system A sterilizer shall have an air removal system such that, when the sterilizer is tested in accordance with 8.4, the pressure in the unloaded chamber is reduced, within 3 min, from ambient atmospheric pressure (i.e. zero gauge pressure) to an absolute pressure n
21、ot exceeding 20 kPa (which may be taken to be a gauge pressure of 80 kPa at sea level). 4.3 Operator controls 4.3.1 General All controls shall be clearly visible and clearly and permanently marked in at least English or, in the case of valve controls and microprocessors, by symbols, to indicate thei
22、r function. Where necessary, the controls shall be suitably extended to a position where they are readily accessible to the operator. Amdt 1 SANS 982:2009 Edition 3.1 5 4.3.2 Handles and handwheels When a sterilizer is tested in accordance with 8.3.3(a), the surface temperature of handles and handwh
23、eels shall not exceed 50 C. 4.4 Cycle and stage controls 4.4.1 Automatic control A sterilizer shall be so designed that once an operating cycle is started on automatic mode, it is completed automatically. 4.4.2 Operating cycle An operating cycle shall consist of the following stages: a) Preliminary
24、stage (for type B sterilizers only) The electric steam generator shall build up steam pressure to a regulated pressure of 240 kPa. b) Stage 1 Air removal Repeated cycles (pulses) of admission of steam into the chamber and evacuation of steam and air from the chamber (using the air removal system) to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SANS9822009HIGHPRESSUREHIGHVACUUMSTEAMSTERILIZERSAUTOCLAVES 高压 真空 蒸汽 灭菌 高压锅 PDF

链接地址:http://www.mydoc123.com/p-1032206.html