SANS 981-2009 High-pressure down-draught steam sterilizers (autoclaves) (with independent steam supply)《高压倒灌蒸气消毒器(高压釜)(独立蒸气供应)》.pdf
《SANS 981-2009 High-pressure down-draught steam sterilizers (autoclaves) (with independent steam supply)《高压倒灌蒸气消毒器(高压釜)(独立蒸气供应)》.pdf》由会员分享,可在线阅读,更多相关《SANS 981-2009 High-pressure down-draught steam sterilizers (autoclaves) (with independent steam supply)《高压倒灌蒸气消毒器(高压釜)(独立蒸气供应)》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA
2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any
3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ISBN 978-0-626-22713-5 SANS 981:2009Edition 2.3Any reference to SABS 981 is deemed to be a reference to this standard (Government Notice No. 1373 of 8 No
4、vember 2002) SOUTH AFRICAN NATIONAL STANDARD High-pressure down-draught steam sterilizers (autoclaves) (with independent steam supply) Published by SABS Standards Division 1 Dr Lategan Road Groenkloof Private Bag X191 Pretoria 0001Tel: +27 12 428 7911 Fax: +27 12 344 1568 www.sabs.co.za SABS SANS 98
5、1:2009 Edition 2.3 Table of changes Change No. Date Scope Amdt 1 1975 The requirements for the centre line height from the floor of doors, the door ring of sliding doors, the graduations on pressure gauges, and the finish on frames have been amended. Amdt 2 1977 The requirement for the thickness of
6、the aluminium casing for the thermal insulating material of sterilizers has been amended. Amdt 3 2009 Amended to change the designation of SABS standards to SANS standards, to delete the reference to national legislation from the text, to update referenced standards and the definition of “acceptable
7、“, to change requirements for steel tubes and for paint, and to change language marking requirements for sterilizers, operating controls and instruction booklets. Foreword This South African standard was approved by National Committee SABS TC 1048, Hospital equipment and supplies, in accordance with
8、 procedures of the SABS Standards Division, in compliance with annex 3 of the WTO/TBT agreement This document was published in June 2009. This document supersedes SABS 981:1973 (edition 2 as modified by amdt 1:1975 and amdt 2:1977). A reference is made in 1.1 NOTE (a) to regulations governing pressu
9、re vessels framed under “the current relevant national legislation“. In South Africa this means the Factories, Machinery and Building Work Act, 1941 (Act No. 22 of 1941). A reference is made in 5.11 to the compliance of electrical equipment with the requirements of the relevant specifications declar
10、ed under “the current relevant national legislation“. In South Africa this means the Standards Act, 1962 (Act No. 33 of 1962). A vertical line in the margin shows where the text has been technically modified by amendment No. 3. SANS 981:2009 Edition 2.3 1 Contents Page Foreword 1 Scope. 3 2 Definiti
11、ons 3 3 Operating requirements . 4 4 Materials. 4 5 Constructional requirements 5 6 Marking . 10 7 Sampling and compliance with the specification 10 8 Inspection and methods of test. 11 8.1 Inspection. 11 8.2 Methods of test 11 Appendix A Applicable standards 12 Appendix B Notes to purchasers. 13 SA
12、NS 981:2009 Edition 2.3 2 This page is intentionally left blank SANS 981:2009 Edition 2.3 3 High-pressure down-draught steam sterilizers (autoclaves) (with independent steam supply) 1 Scope 1.1 This specification covers dimensional, constructional, and safety requirements for high-pressure down-drau
13、ght automatic steam sterilizers (autoclaves) of the horizontal rectangular or cylindrical type for the sterilization of unwrapped instruments and utensils in hospitals and other institutions. NOTE a) The manufacture of the sterilizing chamber of all pressure-type sterilizers is governed by regulatio
14、ns covering pressure vessels framed under the current relevant national legislation (see foreword). Amdt 3 The specification does not purport to supersede or overrule any of the requirements laid down in the Act. b) Sterilizers made to this specification should not be installed in zones of risk asso
15、ciated with the use of flammable anaesthetics unless special precautions are taken in respect of the explosion-proofness of electrical equipment. Amdt 3 c) The titles of standards referred to by number in the specification are given in appendix A. d) Requirements that must be specified by the purcha
16、ser and those that must be agreed upon between supplier and purchaser are listed in appendix B. 2 Definitions 2.1 For the purposes of this specification the following definitions shall apply: acceptable acceptable to the authority administering this specification, or to the parties concluding the pu
17、rchase contract, as relevant Amdt 3 defective sterilizer that fails in one or more respects to comply with the appropriate requirements of the specification lot not more than 20 sterilizers of the same size and construction, from one manufacturer, submitted at any one time for inspection and testing
18、 SANS 981:2009 Edition 2.3 4 3 Operating requirements 3.1 Unless otherwise specified by the purchaser, the sterilizers shall be capable of operating at a temperature of up to 138 C and at a pressure of 240 kPa (gauge), using saturated dry steam supplied at a pressure of not less than 275 kPa and not
19、 more than 420 kPa (gauge) from an independent source. 3.2 The mechanical and electrical controls shall be automatically operated and shall permit the following complete cycle of sterilization: Expulsion of air by the admission of steam, raising of steam pressure to give the pre-set temperature, mai
20、ntaining of steam pressure for the pre-set sterilizing time, exhausting of steam. A separate manually operated valve, and an air filter, shall be fitted to the sterilizer to relieve any vacuum that may form within the chamber. The sterilizer shall also be fitted with a separate manually operated con
21、trol to enable a complete cycle of sterilization to be carried out. 4 Materials 4.1 General Components that are joined or are used as fasteners (e.g. rivets, bolts, nuts, hinges, and fittings) or any other components shall be made of material, that is such that electrolytic corrosion will not occur
22、between abutting surfaces. All materials used for welding shall have mechanical properties and corrosion and erosion resistance of at least the same order as those of the parent metal. Thermal insulating material shall not deteriorate in use and shall not cause corrosion of any part of the sterilize
23、r with which it is in contact. 4.2 Sterilizing chamber, door, and door ring The material used for the chamber, the door, and the door ring shall be in accordance with one of the combinations given in table 1. The quality of the materials and the construction of the sterilizing chamber shall be as la
24、id down in the code of practice for the construction of pressure vessels approved by the Chief Inspector of Factories or other appropriate statutory authority. Table 1 Materials I 2 3 Chamber Door ring Door Stainless steel a) Gun-metal, or b) stainless steel a) Gun-metal, or b) stainless steel Nicke
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SANS9812009HIGHPRESSUREDOWNDRAUGHTSTEAMSTERILIZERSAUTOCLAVESWITHINDEPENDENTSTEAMSUPPLY 高压 倒灌 蒸气 消毒器 独立

链接地址:http://www.mydoc123.com/p-1032205.html