SANS 6059-2010 Water - Mercury content《水 汞含量》.pdf
《SANS 6059-2010 Water - Mercury content《水 汞含量》.pdf》由会员分享,可在线阅读,更多相关《SANS 6059-2010 Water - Mercury content《水 汞含量》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA
2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any
3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ISBN 978-0-626-24442-2 SANS 6059:2010Edition 2.1 SOUTH AFRICAN NATIONAL STANDARD Water Mercury content Published by SABS Standards Division 1 Dr Lategan
4、Road Groenkloof Private Bag X191 Pretoria 0001Tel: +27 12 428 7911 Fax: +27 12 344 1568 www.sabs.co.za SABS SANS 6059:2010 Edition 2.1 Table of changes Change No. Date Scope Amdt 1 2010 Amended to update referenced standards. Foreword This South African standard was approved by National Committee SA
5、BS SC 147A, Water Water sampling and analysis, in accordance with procedures of the SABS Standards Division, in compliance with annex 3 of the WTO/TBT agreement. This document was published in April 2010. This document supersedes SANS 6059:2005 (edition 2). A vertical line in the margin shows where
6、the text has been technically modified by amendment No. 1. SANS 6059:2010 Edition 2.1 1 Water Mercury content 1 Scope and field of application This standard specifies a method for the determination of the mercury content of water and wastewater by using atomic absorption spectrophotometry. The metho
7、d is applicable to the determination of mercury in the concentration range 0,001 mg/L to 0,010 mg/L. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the lat
8、est edition of the referenced document (including any amendments) applies. Information on currently valid national and international standards can be obtained from the SABS Standards Division. SANS 111/ISO 835, Laboratory glassware Graduated pipettes. Amdt 1 SANS 112/ISO 648, Laboratory glassware Si
9、ngle volume pipettes. SANS 115/ISO 385, Laboratory glassware Burettes. Amdt 1 SANS 128/ISO 1042, Laboratory glassware One-mark volumetric flasks. SANS 3696/ISO 3696, Water for analytical laboratory use Specification and test methods. 3 Principle The pretreated water sample is injected into a stannou
10、s chloride solution at a wavelength of 253,6 nm in a cold vapour generator cell atomic absorption system and compared with the peak heights of mercury standards measured under the same conditions. 4 Reagents 4.1 General Unless otherwise specified, only use water that complies with the requirements o
11、f SANS 3696 and reagents of analytical reagent grade. SANS 6059:2010 Edition 2.1 2 4.2 Magnesium perchlorate (MgClO4) Granular, of particle size within the range 0,7 mm to 1,2 mm. 4.3 Nitric acid Concentrated (d at 25 /25 C = 1,42). 4.4 Dilute nitric acid solution 1,5 mL of the concentrated nitric a
12、cid diluted to 1 L with water. 4.5 Nitrogen gas (N2) High purity grade. 4.6 Potassium permanganate solution Dissolve 50 g of potassium permanganate (KMnO4) in water and dilute to 1 000 mL. 4.7 Potassium persulfate solution Dissolve 50 g of potassium persulfate (K2S2O8) in water and dilute to 1 000 m
13、L. 4.8 Sodium chloride-hydroxylamine sulfate solution Dissolve 120 g of sodium chloride and 120 g of hydroxylamine sulfate (NH2OH)2H2SO4) in water and dilute to 1 000 mL. 4.9 Standard mercury solutions 4.9.1 Stock solution (1 000 mg/L) 4.9.1.1 Obtain a commercially available stock solution of mercur
14、y (1 000 mg/L) of guaranteed quality, or prepare a stock solution as described in 4.9.1.2. 4.9.1.2 Dissolve 1,354 0 g of mercuric chloride (HgCl2) in about 700 mL of water, add 1,5 mL of the concentrated nitric acid (see 4.3), and dilute to 1 000 mL with water. 1 mL of this solution contains 1,00 mg
15、 of mercury. 4.9.2 Standard working solution (0,1 mg/L) Dilute 10,00 mL of the stock solution (see 4.9.1) to 1 000 mL with water (see 4.1) in a volumetric flask. Dilute 10,00 mL of the resulting solution with the dilute nitric acid solution (see 4.4) to 1 000 mL in a volumetric flask. 1,00 mL of thi
16、s solution contains 0,1 g of mercury. 4.10 Stannous chloride solution Dissolve 20 g of stannous chloride (SnCl2) in 100 mL of the dilute sulfuric acid solution (see 4.12). 4.11 Sulfuric acid Concentrated (d at 25 /25 C = 1,84). SANS 6059:2010 Edition 2.1 3 4.12 Dilute sulfuric acid solution 53 mL of
17、 the concentrated sulfuric acid diluted to 1 L with water. 5 Apparatus 5.1 Atomic absorption spectrophotometer, together with the associated equipment, and a recorder. 5.2 Mercury hollow-cathode lamp. 5.3 Glass atomizing tube, as shown in figure 1. 5.4 Drying tube, 150 mm 18 mm, as shown in figure 2
18、. 5.5 Cold vapour generator cell, as shown in figure 2. 5.6 Syringe, capable of delivering 10,0 mL. 5.7 Rotameter, to set the nitrogen flow rate at 400 mL/min to 500 mL/min. 5.8 Glassware. Where applicable, only use burettes, pipettes and volumetric flasks that comply with the requirements for class
19、 A items as specified in SANS 111, SANS 112, SANS 115 and SANS 128, as relevant. Amdt 1 6 Procedure 6.1 Instrument operation NOTE The differences between makes and models of atomic absorption spectrophotometers make it impracticable to formulate detailed operating instructions. Follow the manufactur
20、ers operating instructions for the specific instrument but, in general, proceed in accordance with the instructions given in 6.1.1 to 6.1.7 6.1.1 Turn on the instrument, install the mercury hollow-cathode lamp (see 5.2) and apply the current recommended by the manufacturer. 6.1.2 Set the wavelength
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SANS60592010WATERMERCURYCONTENT 含量 PDF
