《REG NASA-LLIS-0568-1997 Lessons Learned Battery Popping During ATLO (Assembly Test and Launch Operations) Due to Horizontal Mounting.pdf》由会员分享,可在线阅读,更多相关《REG NASA-LLIS-0568-1997 Lessons Learned Battery Popping During ATLO (Assembly Test and Launch Operations) Due to Horizontal Mounting.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Lessons Learned Entry: 0568Lesson Info:a71 Lesson Number: 0568a71 Lesson Date: 1997-08-28a71 Submitting Organization: JPLa71 Submitted by: K. Clark/D. OberhettingerSubject: Battery “Popping“ During ATLO (Assembly Test and Launch Operations) Due to Horizontal Mounting Abstract: During Mars Global Sur
2、veyor system test, it was discovered that horizontally mounted nickel-hydrogen battery cells are subject to electrolyte “pooling” in a 1 g. environment. This can damage the cells; high charge rates (and temperatures) increase the likelihood of damage. Some measures to prevent battery popping (rapid
3、oxygen-hydrogen recombination under fast charge conditions) are recommended for nickel-hydrogen batteries during any ground phase.Description of Driving Event: Mars Global Surveyor (MGS) carries two nickel-hydrogen (NiH2) battery assemblies: one mounted to the +Y and one to the -Y propulsion module.
4、 Each assembly consists of eight 20Ahr NiH2 common pressure vessels (CPVs) in a honeycomb composite enclosure mounted on an aluminum baseplate. During MGS system test, shortly after installation of the batteries on the spacecraft, an intermittent “popping“ or “snapping“ sound issued from both batter
5、ies. This noise was most likely caused by oxygen-hydrogen (H2/O2) recombination in the battery under the fast charge rate conditions normally present throughout the charge cycle. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-H2/O2 recombination is
6、a natural chemical process which occurs mostly during the late charge and early discharge stages of NiH2 battery operation. Audible popping occurs during H2/O2 recombination when a large enough oxygen bubble is allowed to form on an electrode plate inside the cell stack before it can recombine with
7、hydrogen. When this bubble finally does recombine, a popping sound results. Such popping may induce significant damage to cell plates and may reduce battery cycle life.This phenomenon was exacerbated by the MGS practice of mounting and testing the battery on its side (i.e., horizontally) in a 1 g. e
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- REGNASALLIS05681997LESSONSLEARNEDBATTERYPOPPINGDURINGATLOASSEMBLYTESTANDLAUNCHOPERATIONSDUETOHORIZONTALMOUNTINGPDF

链接地址:http://www.mydoc123.com/p-1018215.html