1、AMSC N/A FSC 6645 INCH-POUND MS21341H 19 October 2012 SUPERSEDING MS21341G 15 December 1982 DETAIL SPECIFICATION SHEET METER, TIME TOTALIZING, HERMETICALLY SEALED, 28 VDC This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiri
2、ng the product described herein shall consist of this specification sheet and MIL-DTL-7793. FIGURE 1. Meter configuration. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS21341H 2 NOTES: 1. Dimensions are in inches. 2. Unless otherwise specified, t
3、olerance is .02 for two place decimals and .005 for three place decimals 3. For design feature purposes, this specification sheet takes precedence over documents referenced herein. 4. Referenced documents shall be of the issue in effect on the date of invitation for bid. 5. Optional radius applies t
4、o all corners and edges. 6. Exposed tin plate on this surface of mounting flange only, per ASTM-B545, to provide an electrical ground for the case. 7. Marking surface is optional. Marking must not be obscured by mounting bracket. 8. Polarity marking (+) near positive terminal on this surface. REQUIR
5、EMENTS: 1. Dimensions. See Figure 1 and Table I. 2. Electrical. Unless otherwise specified, all tests shall be at room pressure and temperature, approximately +23 C. 3. Meter range. 0 to 9999 hours. 4. Scale designator. Hours 5. Mounting flange. Per Note 6 above, tin-plate .0002 to .0004-inch thick
6、to provide means for electrical ground of the case (see Figure 1). 6. Transient protection. No temporary or permanent degradation shall be produced in the meter for the input voltage and time values shown on Figure 2 and Figure 3 (80V and 600V transient, respectively). 7. Ripple protection. The mete
7、r must maintain the accuracy specified in Table I when subjected to a cyclic peak of ripple voltage of less than 2.0 VDC and the frequency-voltage coordinates of Figure 4. 8. Operational check. The meter shall register accurate time over the input voltage range specified in Table I between -65 C and
8、 +125 C. 9. Case finish. The case shall be finished in a durable, dull or semi-gloss black color. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS21341H 3 FIGURE 2. Transient surge step function loci limits. DC Volts Time (Seconds)Provided by IHSNo
9、t for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS21341H 4 FIGURE 3. Envelope of spike voltages for direct current. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS21341H 5 FIGURE 4. Frequency characteristics of rip
10、ple in 28 VDC electric systems. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS21341H 6 10. Marking. The meter shall remain clearly and legibly marked with the following information after subjection to the environmental requirements: (a) Part numb
11、er (Example: MS21341A-05) (b) Source and date code per MIL-STD-1285. (c) 28 VDC Nominal Voltage. TABLE I. Meter configuration and requirements. Requirement MS21341A MS21341B Case Length, Inch (See Figure 1) 1.094/1.047 2.062/2.000 Maximum Weight, Ounce 0.6 1.5 Input Voltage Range, VDC 10 to 34 23 to
12、 32 Nominal Input Power, Watt 0.085 (Average) 1.000 Maximum Input Power, Watt 0.150 (Average) 1.500 Accuracy, Percent 0.1 1.0 TABLE II. Mount setback dash numbers and dimensions (see Figure 1). Dash Number Dim A .015 Dash Number Dim A .015 Dash Number Dim A .015 -01 .000 -10 .281 -19 .562 -02 .031 -
13、11 .312 -20 .594 -03 .062 -12 .344 -21 .625 -04 .094 -13 .375 -22 .656 -05 .125 -14 .406 -23 .688 -06 .156 -15 .438 -24 .719 -07 .188 -16 .469 -25 .750 -08 .218 -17 .500 -26 .781 -09 .250 -18 .531 11. Conformance inspection. The following tests, run in the order shown on all meters, supersede the in
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMS21341REVH2012METERTIMETOTALIZINGHERMETICALLYSEALED28VDCPDF

链接地址:http://www.mydoc123.com/p-983628.html