《NAVY MIL-PRF-85045 26 A-2010 CABLE FIBER OPTIC ONE TUBE BLOWN OPTICAL FIBER STANDARD AND ENHANCED PERFORMANCE CABLE CONFIGURATION TYPE 5 (TUBE) APPLICATION B (SHIPBOARD) CABLE CLAS.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-PRF-85045 26 A-2010 CABLE FIBER OPTIC ONE TUBE BLOWN OPTICAL FIBER STANDARD AND ENHANCED PERFORMANCE CABLE CONFIGURATION TYPE 5 (TUBE) APPLICATION B (SHIPBOARD) CABLE CLAS.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、 METRIC MIL-PRF-85045/26A 19 January 2010 SUPERSEDING MIL-PRF-85045/26 18 May 2001 PERFORMANCE SPECIFICATION SHEET CABLE, FIBER OPTIC, ONE TUBE, BLOWN OPTICAL FIBER, STANDARD AND ENHANCED PERFORMANCE, CABLE CONFIGURATION TYPE 5 (TUBE), APPLICATION B (SHIPBOARD), CABLE CLASS SM AND MM (METRIC) This s
2、pecification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-PRF-85045. CLASSIFICATION: Fiber optic cable configuration type (Tube): 5 MM (graded-index, gla
3、ss core and glass cladding, multimode) Fiber cable class: SM (dispersion-unshifted, glass core and glass cladding, single mode) DESIGN AND CONSTRUCTION: Blown optical fiber tube: Dimensions and configuration: See figure 1. FIGURE 1. Blown optical fiber tube. Short-term minimum bend diameter: 127 mil
4、limeters Long-term minimum bend diameter: 127 millimeters AMSC N/A FSC 6015 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-85045/26A Tensile loading: 89 Newtons Tube material: The tube shall be composed of a low halogen, low smoke, and low t
5、oxicity polymer material. Finished cable: Dimensions and configuration: See figure 2. An outer jacket shall be applied over strength members and a central tube. The minimum outer jacket thickness shall be not less than 1.15 millimeters. FIGURE 2. Single-tube cable. Concentricity: 0.65 Jacket materia
6、l: The overall jacket shall be composed of a low halogen, low smoke, and low toxicity polymer material. Cable jacket color: Shall be black or blue Mass per unit length: 120.0 kg/km Short-term minimum bend diameter: 127 millimeters. (The short-term minimum bend diameter is to be used in all environme
7、ntal and mechanical tests that specify a cable minimum bend diameter.) Long-term minimum bend diameter: 127 millimeters PERFORMANCE REQUIREMENTS: Specimen lengths: 3 units, 0.305 kilometers each Optical properties: Attenuation rate: Not applicable Change in optical transmittance: Not applicable Cros
8、stalk: Not applicable Mechanical properties: Tensile loading and elongation: Applicable, tensile loading 445 Newtons. Change in optical transmittance is not applicable. A ball bearing with a minimum outer diameter of 4.0 millimeters shall pass through the tube after the test. Operating tensile loadi
9、ng: Applicable, tensile loading 267 Newtons. Change in optical transmittance is not applicable. A ball bearing with a minimum outer diameter of 4.0 millimeters shall pass through the tube during and after the test. Dynamic bend: Not applicable 2 Provided by IHSNot for ResaleNo reproduction or networ
10、king permitted without license from IHS-,-,-MIL-PRF-85045/26A Low temperature flexibility: Applicable, except the change in optical transmittance is not applicable. For standard performance, the exposure temperature shall be the minimum operating temperature. For enhanced performance, the exposure t
11、emperature shall be 40 C. A ball bearing with a minimum outer diameter of 4.0 millimeters shall pass through the tube after the test. Cyclic flexing: 500 cycles at +252 C and 100 cycles at 282 C. Change in optical transmittance is not applicable. A ball bearing with a minimum outer diameter of 4.0 m
12、illimeters shall pass through the tube after every 100 cycles for the 500-cycle exposure and every 25 cycles for the 100-cycle exposure. The cycling may be halted to perform the ball bearing test. Crush: Applicable, except that the load shall be 950 Newtons and the change in optical transmittance an
13、d crosstalk are not applicable. A ball bearing with a minimum outer diameter of 4.0 millimeters shall pass through the tube after the load is removed. Cable twist bending: Not applicable. Radial compression: Applicable, except the change in optical transmittance is not applicable. A ball bearing wit
14、h a minimum outer diameter of 4.0 millimeters shall pass through the tube during and after the test. Impact: Applicable, except that the drop hammer mass shall be 1.5 kilograms. Fifty cycles shall be conducted at +252 C and 20 cycles shall be conducted at -402 C. The change in optical transmittance
15、is not applicable. A ball bearing with a minimum outer diameter of 4.0 millimeters shall pass through the tube after the test. Corner bend: Applicable, except the change in optical transmittance is not applicable. A ball bearing with a minimum outer diameter of 4.0 millimeters shall pass through eac
16、h tube after the test. Cable jacket tear strength: Applicable, except the cable jacket tear strength shall be not less than 35 Newtons per centimeter (N/cm) for standard performance cable. Tube tensile strength and elongation: Tube specimens shall be tested in accordance with FED-STD-228, Method 302
17、1 and 3031, with 2.5 cm (0.98 inch) benchmarks, 6.35 cm (2.5 inch) jaw separation, and a rate of travel of 25 cm/min (9.8 inch/min). The tensile strength of the tube shall be not less than 900 N/cm. The percent elongation-at-break shall be not less than 125 percent. Capstan grips may be used. Hosing
18、: Low pressure: Applicable. Tube ends shall be capped with end caps during this test. Hydrostatic: Not applicable Dripping: Applicable Cable scraping resistance: 750 cycles Cable to cable abrasion: 500 cycles Cable shrinkage: Applicable, except that the total shrinkage shall be not greater than 35 m
19、illimeters. Pressure withstand: One end of the inner tube shall be capped and a static pressure of 1.4 MPa (200 psi) applied internal to the tube for 10 minutes. After the test, tubes shall show no evidence of splitting, cracking, or rupture. Environmental properties: Temperature range: Operating: -
20、28 to +65 C Nonoperating: -40 to +70 C Storage: -40 to +70 C 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-85045/26A Temperature cycling: Change in optical transmittance is not applicable. A ball bearing with a minimum outer diameter of 4
21、.0 millimeters shall pass through the tube at the high temperature plateau, the low temperature plateau, and after the test. Thermal shock: Not applicable Temperature humidity cycling: Change in optical transmittance is not applicable. A ball bearing with a minimum outer diameter of 4.0 millimeters
22、shall pass through the tube at the high temperature plateau, the low temperature plateau, and after the test. Storage temperature: Applicable, except the change in optical transmittance is not applicable. A ball bearing with a minimum outer diameter of 4.0 millimeters shall pass through the tube aft
23、er the test. Life aging: Applicable, except the change in optical transmittance is not applicable and a minimum test sample length of 150 meters may be used. For standard performance product, the test shall be conducted as specified in the basic specification. For enhanced performance product, the t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILPRF8504526A2010CABLEFIBEROPTICONETUBEBLOWNOPTICALFIBERSTANDARDANDENHANCEDPERFORMANCECABLECONFIGURATIONTYPE5TUBEAPPLICATIONBSHIPBOARDCABLECLASPDF

链接地址:http://www.mydoc123.com/p-981066.html