《NAVY MIL-PRF-85045 25 A-2010 CABLE FIBER OPTIC SEVEN TUBE BLOWN OPTICAL FIBER STANDARD AND ENHANCED PERFORMANCE CABLE CONFIGURATION TYPE 5 (TUBE) APPLICATION B (SHIPBOARD) CABLE CL.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-PRF-85045 25 A-2010 CABLE FIBER OPTIC SEVEN TUBE BLOWN OPTICAL FIBER STANDARD AND ENHANCED PERFORMANCE CABLE CONFIGURATION TYPE 5 (TUBE) APPLICATION B (SHIPBOARD) CABLE CL.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、 METRIC MIL-PRF-85045/25A 19 January 2010 SUPERSEDING MIL-PRF-85045/25 18 May 2001 PERFORMANCE SPECIFICATION SHEET CABLE, FIBER OPTIC, SEVEN TUBE, BLOWN OPTICAL FIBER, STANDARD AND ENHANCED PERFORMANCE, CABLE CONFIGURATION TYPE 5 (TUBE), APPLICATION B (SHIPBOARD), CABLE CLASS SM AND MM (METRIC) This
2、 specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-PRF-85045. CLASSIFICATION: Fiber optic cable configuration type (Tube): 5 MM (graded-index, g
3、lass core and glass cladding, multimode) Fiber cable class: SM (dispersion-unshifted, glass core and glass cladding, single mode) DESIGN AND CONSTRUCTION: Blown optical fiber tube: Dimensions and configuration: See figure 1. FIGURE 1. Blown optical fiber tube. Short-term minimum bend diameter: 127 m
4、illimeters Long-term minimum bend diameter: 127 millimeters AMSC N/A FSC 6015 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-85045/25A Tensile loading: 89 Newtons Tube material: The tube shall be composed of a low halogen, low smoke, low tox
5、icity polymer material. Tube marking: Each tube shall be uniquely marked with a number between 1 and 7. The form of the marking shall be the printed spelling of the number, followed by a dash, followed by the printed Arabic numeral. The marking shall be applied and repeated every 0.10 meters (4 inch
6、es) along the tube. Tube number 1 shall be located in the center of the cable. Finished cable: Dimensions and configuration: See figure 2. Six tubes shall be helically laid over a central tube. The minimum outer jacket thickness shall be not less than 1.65 mm. FIGURE 2. Seven-tube cable. Concentrici
7、ty: 0.65 Jacket material: The overall jacket shall be composed of a low halogen, low smoke, and low toxicity polymer material. Cable jacket color: Shall be black or blue Mass per unit length: 775.0 kg/km Short-term minimum bend diameter: 0.45 meters. (The short-term minimum bend diameter is to be us
8、ed in all environmental and mechanical tests that specify a cable minimum bend diameter.) Long-term minimum bend diameter: 0.45 meters PERFORMANCE REQUIREMENTS: Specimen lengths: 3 units, 0.305 kilometers each Optical properties: Attenuation rate: Not applicable Change in optical transmittance: Not
9、applicable Crosstalk: Not applicable 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-85045/25A Mechanical properties: Tensile loading and elongation: Applicable, tensile loading 3,300 Newtons. Change in optical transmittance is not applicab
10、le. A ball bearing with a minimum outer diameter of 4.0 millimeters shall pass through each tube after the test. Operating tensile loading: Applicable, except change in optical transmittance is not applicable. A ball bearing with a minimum outer diameter of 4.0 millimeters shall pass through each tu
11、be during and after the test. Dynamic bend: Not applicable Low temperature flexibility: The following procedure shall be used. A 1.5-meter test specimen shall be placed in a straight configuration and conditioned at the exposure temperature for 4 hours. For standard performance cable, the exposure t
12、emperature shall be the minimum operating temperature. For enhanced performance cable, the exposure temperature shall be -40 C. The test specimen shall be removed from the conditioning chamber and formed into a single loop around a mandrel with a diameter equal to the cable short-term minimum bend d
13、iameter. The time between the removal of the cable from the chamber to the completion of the loop shall be a maximum of 50 seconds. The specimen shall be secured to maintain its bent shape and allowed to return to room temperature. A ball bearing with a minimum outer diameter of 4.0 millimeters shal
14、l pass through each tube after the test. Cyclic flexing: 100 cycles at +252 C and 20 cycles at -282 C. Change in optical transmittance is not applicable. A ball bearing with a minimum outer diameter of 4.0 millimeters shall pass through each tube after every 25 cycles for the 100-cycle exposure and
15、after the 20-cycle exposure. The cycling may be halted to perform the ball bearing test. Crush: Applicable, except that the load shall be 2650 Newtons and the change in optical transmittance and crosstalk are not applicable. A ball bearing with a minimum outer diameter of 4.0 millimeters shall pass
16、through each tube after the load is removed. Cable twist bending: Not applicable Radial compression: Applicable, except the change in optical transmittance is not applicable. A ball bearing with a minimum outer diameter of 4.0 millimeters shall pass through each tube during and after the test. Impac
17、t: Applicable, except that the drop hammer mass shall be 6 kilograms. Fifty cycles shall be conducted at +252 C and 20 cycles shall be conducted at -402 C. The change in optical transmittance is not applicable. A ball bearing with a minimum outer diameter of 4.0 millimeters shall pass through each t
18、ube after the test. Corner bend: Applicable, except the change in optical transmittance is not applicable. A ball bearing with a minimum outer diameter of 3.0 millimeters shall pass through each tube during the test. A ball bearing with a minimum outer diameter of 4.0 millimeters shall pass through
19、each tube after the test. Cable jacket tear strength: Applicable, except the cable jacket tear strength shall be not less than 35 Newtons per centimeter (N/cm) of jacket thickness for standard performance cable. Tube tensile strength and elongation: Tube specimens shall be tested in accordance with
20、FED-STD-228, Method 3021 and 3031, with 2.5 cm (0.98 inch) benchmarks, 6.35 cm (2.5 inch) jaw separation, and a rate of travel of 25 cm/min (9.8 inch/min). The tensile strength of the tube shall be not less than 900 N/cm2. The percent elongation-at-break shall be not less than 125 percent. Capstan g
21、rips may be used. Hosing: Low pressure applicable, except the cable leakage shall be not greater than 175 milliliters. Tube ends shall be capped with end caps during this test. Hydrostatic: Not applicable Dripping: Applicable Cable scraping resistance: 750 cycles Cable to cable abrasion: 500 cycles
22、3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-85045/25A Cable shrinkage: Applicable, except that the total shrinkage shall be not greater than 35 millimeters. Pressure withstand: One end of three tubes shall be capped and a static pressur
23、e of 1.4 MPa (200 psi) applied internal to the tube for 10 minutes. After the test, tubes shall show no evidence of splitting, cracking, or rupture. Environmental properties: Temperature range: Operating: -28 to +65 C Nonoperating: -40 to +70 C Storage: -40 to +70 C Temperature cycling: Change in op
24、tical transmittance is not applicable. A ball bearing with a minimum outer diameter of 4.0 millimeters shall pass through each tube at the high temperature plateau, the low temperature plateau, and after the test. Thermal shock: Not applicable Temperature humidity cycling: Change in optical transmit
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILPRF8504525A2010CABLEFIBEROPTICSEVENTUBEBLOWNOPTICALFIBERSTANDARDANDENHANCEDPERFORMANCECABLECONFIGURATIONTYPE5TUBEAPPLICATIONBSHIPBOARDCABLECLPDF

链接地址:http://www.mydoc123.com/p-981065.html