1、 AMSC N/A FSC 1660 MIL-DTL-19803G 05 February 2007 SUPERSEDING MIL-C-19803F 24 March 1982 DETAIL SPECIFICATION CONVERTER, LIQUID OXYGEN, 10-LITER, GCU-24A/A Reactivated after 05 February 2007 and may be used for new and existing designs and acquisitions. This specification is approved for use by all
2、 Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers one type of aircraft converter, GCU-24A/A, used for storing and pressuring 10 liters of liquid oxygen. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sect
3、ions 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must me
4、et all specified requirements of documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent speci
5、fied herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. Comments, suggestions, or questions on this document should be addressed to: Commander, Naval Air Warfare Center Aircraft Division, Code 491000B120-3, Highway 547, Lakehurst, NJ 08
6、733-5100 or emailed to thomas.omaranavy.mil. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at http:/assist.daps.dla.mil.INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without lic
7、ense from IHS-,-,-MIL-DTL-19803G 2 FEDERAL STANDARD FED-STD-595 - Colors Used in Government Procurement: Color number: 14187 COMMERCIAL ITEM DESCRIPTIONS A-A-58092 - Tape, Antiseize, Polytetrafluorethylene A-A-59503 - Nitrogen, Technical DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-PRF-9050 - Valves, Ox
8、ygen, Pressure Relief, Aircraft MIL-DTL-25516 - Connectors, Electrical, Miniature, Coaxial, Environment Resistant Type, General Specification for MIL-PRF-25567 - Leak Detection Compound, Oxygen Systems MIL-PRF-25961 - Valve, Fill-Buildup-Vent, Liquid Oxygen Converter, CRU-50/A MIL-PRF-27210 - Oxygen
9、, Aviators Breathing, Liquid and Gas DEPARTMENT OF DEFENSE STANDARDS MIL-STD-129 - Military Marking for Shipment and Storage MIL-STD-130 - Identification Marking of U.S. Military Property MIL-STD-461 - Requirements for the Control of Electromagnetic Interference Characteristics of Subsystems and Equ
10、ipment MIL-STD-810 - Environmental Engineering Considerations and Laboratory Tests MIL-STD-889 - Dissimilar Metals MIL-STD-1916 - DoD Preferred Methods for Acceptance of Product Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-19803G 3 MS22068
11、 - Coupling Assemblies, Quick Disconnect, Aircraft Liquid Oxygen Systems. (Inactive for New Design) MS90341 - Mounting Bracket, Configuration, Mating Portion for 5 and 10 Liter Liquid Oxygen Converters. (Inactive for New Design) DEPARTMENT OF DEFENSE HANDBOOK MIL-HDBK-781 - Reliability Test Methods,
12、 Plans, and Environments for Engineering Development, Qualification, and Production (Copies of these documents are available online at http:/assist.daps.dla.mil/quicksearch or http:/assist.daps.dla.mil or from the Standardization Document Order Desk, Building 4D, 700 Robbins Avenue, Philadelphia, PA
13、 19111-5094.) 2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. AMERICAN SOCIETY FOR QUALITY (ASQ) ASQ-Z1.4 - Sampling Proced
14、ures and Tables for Inspection for Attributes. (DoD Adopted) (Copies of this document are available from the American Society for Quality, 600 North Plankinton Avenue, Milwaukee, WI 53203-4606 or http:/www.asq.org.) SOCIETY OF AUTOMOTIVE ENGINEERS (SAE) SAE-ARP1176 - Oxygen System and Component Clea
15、ning and Packaging. (DoD Adopted) (Copies of this document are available from www.sae.org or SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001.) 2.4 Order of precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this
16、document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-19803G 4 3. REQUIREMENTS 3.1 Qualification
17、. The converter furnished under this specification shall be a product that is authorized by the qualifying activity for listing on the applicable qualified products lists before contract award (see 4.1 and 6.3). 3.2 First article. When specified (see 6.2), the converter shall be subjected to first a
18、rticle inspection in accordance with 4.3 and 6.4. 3.3 Materials. Materials shall conform to applicable specifications and shall be as specified herein and on applicable drawings. Materials which are not covered by specifications, or which are not specifically described herein, shall be of the best q
19、uality, of the lightest practicable weight, and for the purpose intended. 3.3.1 Metal parts. All metals parts shall be of a corrosion-resistant material or treated in a manner to render them resistant to corrosion. 3.3.1.1 Dissimilar metals. Unless protected against electrolytic corrosion, dissimila
20、r metals shall not be used in intimate contact with each other. Dissimilar metals are specified in MIL-STD-889. 3.3.2 Nonmetallic materials. Any nonmetallic material that is affected by continued use with oxygen shall not be used. 3.3.2.1 Age. Elastomer components, except silicon, shall be not great
21、er than 12 months old from the date of manufacture to the date of delivery to any Government Service or to any airframe or accessory manufacturer. 3.3.3 Protective treatment. When materials are used in the construction of the converter that are subject to deterioration when exposed to environmental
22、conditions likely to occur during service usage, they shall be protected against such deterioration in a manner that shall in no way prevent compliance with the performance requirements (see 3.5) of this specification. Protective coating which might crack, chip or scale during normal service life or
23、 under extremes of environmental conditions shall not be used. 3.4 Design and construction. The design and construction shall be in accordance with figures 1, 2, 3, and 4. The converter shall include provisions for filling with liquid oxygen when either installed or not installed in the aircraft and
24、 for being transported in the filled condition. The converter shall consist of the following major components: Container Container outer shell Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-19803G 5 Sensing element Electrical connectors Comb
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILDTL19803G2007CONVERTERLIQUIDOXYGEN10LITERGCU24AAGCU24AA 10 液态 变流器 PDF

链接地址:http://www.mydoc123.com/p-978498.html