ISA 60079-2-2010 Explosive Atmospheres - Part 2 Equipment protection by pressurized enclosures “p” (12 04 01)《爆炸性环境 第2部分 增压罩对设备的防护 2 04 01[代替 ISA 12 04 01和ISA 12 04 01]》.pdf
《ISA 60079-2-2010 Explosive Atmospheres - Part 2 Equipment protection by pressurized enclosures “p” (12 04 01)《爆炸性环境 第2部分 增压罩对设备的防护 2 04 01[代替 ISA 12 04 01和ISA 12 04 01]》.pdf》由会员分享,可在线阅读,更多相关《ISA 60079-2-2010 Explosive Atmospheres - Part 2 Equipment protection by pressurized enclosures “p” (12 04 01)《爆炸性环境 第2部分 增压罩对设备的防护 2 04 01[代替 ISA 12 04 01和ISA 12 04 01]》.pdf(78页珍藏版)》请在麦多课文档分享上搜索。
1、 AMERICAN NATIONAL STANDARD ANSI/ISA-60079-2 (12.04.01)-2010 Supercedes ANSI/ISA-12.04.01-2004 (IEC 60079-2 Mod) Explosive Atmospheres Part 2: Equipment protection by pressurized enclosures “p” Approved 27 August 2010 ANSI/ISA-60079-2 (12.04.01)-2010 Explosive atmospheres - Part 2: Equipment protect
2、ion by pressurized enclosures “p“ ISBN: 978-1-936007-57-8 Copyright 2010 by the International Society of Automation (ISA). These materials are subject to copyright claims of IEC, ANSI, and ISA. All rights reserved. Not for resale. Printed in the United States of America. No part of this publication
3、may be reproduced in any form, including an electronic retrieval system without the prior written permission of the Publisher. All requests pertaining to this Standard should be submitted to ISA. ISA 67 Alexander Drive P.O. Box 12277 Research Triangle Park, North Carolina 27709 - 3 - ANSI/ISA-60079-
4、2 (12.04.01)-2010 Preface This preface, as well as all footnotes and annexes, is included for information purposes and is not part of ANSI/ISA-60079-2 (12.04.01)-2010. This document has been prepared as part of the service of ISA toward a goal of uniformity in the field of instrumentation. To be of
5、real value, this document should not be static but should be subject to periodic review. Toward this end, the Society welcomes all comments and criticisms and asks that they be addressed to the Secretary, Standards and Practices Board; ISA; 67 Alexander Drive; P. O. Box 12277; Research Triangle Park
6、, NC 27709; Telephone (919) 549-8411; Fax (919) 549-8288; E-mail: standardsisa.org. The ISA Standards and Practices Department is aware of the growing need for attention to the metric system of units in general, and the International System of Units (SI) in particular, in the preparation of instrume
7、ntation standards. The Department is further aware of the benefits to USA users of ISA standards of incorporating suitable references to the SI (and the metric system) in their business and professional dealings with other countries. Toward this end, this Department will endeavor to introduce SI-acc
8、eptable metric units in all new and revised standards, recommended practices, and technical reports to the greatest extent possible. Standard for Use of the International System of Units (SI): The Modern Metric System, published by the American Society for Testing figures to be deleted are marked wi
9、th the overlay “X.“ There are ten annexes in this standard. Annexes B, C, D, F, H, I and J are informative and are not considered part of this standard. Annexes A, E and G are normative and are considered part of this standard. This page intentionally left blank. -13- ANSI/ISA-60079-2 (12.04.01)-201
10、0 INTRODUCTION This part of IEC 60079 standard gives requirements for the design, construction, testing and marking of electrical apparatus for use in potentially explosive atmospheres in which a) a protective gas maintained at a pressure above that of the external atmosphere is used to guard agains
11、t the formation of an explosive gas atmosphere within enclosures which do not contain an internal source of release of flammable gas or vapour and, where necessary; b) a protective gas is provided in sufficient quantity to ensure that the resultant mixture concentration around the electrical parts i
12、s maintained at a value outside the explosive limit appropriate to the particular conditions of use. The protective gas is supplied to an enclosure containing one or more internal sources of release in order to guard against the formation of an explosive gas atmosphere. This standard includes requir
13、ements for the apparatus and its associated equipment including the inlet and exhaust ducts, and also for the auxiliary control apparatus necessary to ensure that pressurization and/or dilution is established and maintained. This page intentionally left blank. -15- ANSI/ISA-60079-2 (12.04.01)-2010 1
14、 Scope This part of IEC 60079 standard contains the specific requirements for the construction and testing of electrical apparatus with pressurized enclosures, of type of protection “p”, intended for use in explosive gas atmospheres hazardous (classified) locations defined as Class I, Zone 1 or Zone
15、 2 by the National Electrical Code (NEC), ANSI/NFPA 70. It specifies requirements for pressurized enclosures containing a limited release of a flammable substance. This standard supplements and modifies the general requirements of IEC ANSI/ISA-60079-0. Where a requirement of this standard conflicts
16、with a requirement of IEC ANSI/ISA-60079-0, the requirements of this standard takes precedence. This standard does not contain the requirements for: pressurized enclosures where the containment system may release a) air with an oxygen content greater than normal, or b) oxygen in combination with ine
17、rt gas in a proportion greater than 21 %; pressurized rooms or analyser houses; see IEC 60079-13 and IEC 60079-16. NOTE 1 Due to the safety factors incorporated in the type of protection, the uncertainty of measurement inherent in good quality, regularly calibrated measurement equipment is considere
18、d to have no significant detrimental effect and need not be taken into account when making the measurements necessary to verify compliance of the equipment with the requirements of this standard. NOTE 2 When the user acts in the role of the manufacturer, it is typically the users responsibility to e
19、nsure that all relevant parts of this standard are applied to the manufacturing and testing of the equipment. NOTE 3 Types of protection “px” and “py” provide Equipment Protection Levels (EPL) Mb or Gb. Type of protection “pz” provides Equipment Protection Level (EPL) Gc. For further information, se
20、e Annex H. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60034-5, Ro
21、tating electrical machines Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code ) Classification IEC 60050(151), International Electrotechnical Vocabulary Chapter 151: Electrical and magnetic devices IEC 60050(426), International Electrotechnical Voc
22、abulary Chapter 426: Electrical apparatus for explosive atmospheres IEC ANSI/ISA-60079-0:2007, Electrical apparatus for explosive gas atmospheres Part 0: General requirements ANSI/ISA-60079-2 (12.04.01)-2010 -16- IEC 60112, Method for the determination of the proof and the comparative tracking indic
23、es of solid insulating materials IEC 60529, Degrees of protection provided by enclosures (IP Code) IEC 60664-1:1992, Insulation coordination for equipment within low-voltage systems Part 1: Principles, requirements and tests ANSI/NFPA 70 National Electrical Code 3 Terms and definitions For the purpo
24、ses of this document, the terms and definitions given in IEC 60050(151), IEC 60050(426) and IEC ANSI/ISA-60079-0, as well as the following apply. NOTE Unless otherwise specified, the terms “voltage“ and “current“ mean the r.m.s. values of an alternating, direct or composite voltage or current. 3.1 a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISA6007922010EXPLOSIVEATMOSPHERESPART2EQUIPMENTPROTECTIONBYPRESSURIZEDENCLOSURES 120401 爆炸性 环境 部分 增压

链接地址:http://www.mydoc123.com/p-789719.html