ISA 20-1981 Specification Forms for Process Measurement and Control Instruments Primary Elements and Control Valves《过程测量和控制仪表 主要元件和控制阀的规范形式》.pdf
《ISA 20-1981 Specification Forms for Process Measurement and Control Instruments Primary Elements and Control Valves《过程测量和控制仪表 主要元件和控制阀的规范形式》.pdf》由会员分享,可在线阅读,更多相关《ISA 20-1981 Specification Forms for Process Measurement and Control Instruments Primary Elements and Control Valves《过程测量和控制仪表 主要元件和控制阀的规范形式》.pdf(98页珍藏版)》请在麦多课文档分享上搜索。
1、Specification Forms forProcess Measurement andControl Instruments, PrimaryElements, and Control ValvesApproved 30 October 1981ISA201981 FormerlyISAS201981STANDARDISA The Instrumentation,Systems, andAutomation Society TMCopyright 1981 by the Instrument Society of America. All rights reserved. Printed
2、 in the UnitedStates of America. No part of this publication may be reproduced, stored in a retrieval system, ortransmitted in any form or by any means (electronic, mechanical, photocopying, recording, orotherwise), without the prior written permission of the publisher.ISA67 Alexander DriveP.O. Box
3、12277Research Triangle Park, North Carolina 27709ISA-20-1981, Specification Forms for Process Measurement and Control Instruments, Primary Elements and Control ValvesISBN 0-87664-347-0ISA-S20-1981 3PrefaceThis Preface is included for information purposes and is not part of ISA-20-1981.This Standard
4、has been prepared as a part of the service of the ISA toward a goal of uniformity in the field of instrumentation. To be of real value this report should not be static, but should be subjected to periodic review. Toward this end the Society welcomes all comments and criticisms, and asks that they be
5、 addressed to the Standards and Practices Board Secretary, ISA, 67 Alexander Drive, P.O. Box 12277, Research Triangle Park, North Carolina 27709, Telephone (919) 549-8411, Fax (919) 549-8288, e-mail: standardsisa.org.This document was prepared by the Subcommittee on Instrument Specification Forms (R
6、P20.1) and was originally published in 1956 under the direction of G. G. Gallagher of the Fluor Corporation. In 1961 additional forms were published, prepared by Committee 8D-RP20 under the direction of W. Carmack of the Fluor Corporation. This revision was prepared, with the supervision of the Chai
7、rman, R. E. Frey of Rohm and Haas Company, by the committee as listed below.SP20 COMMITTEENAME COMPANYR. E. Frey (deceased) Rohm and Haas CompanyW. S. Buzzard Fisher and Porter CompanyJ. G. Converse Sun Oil CompanyG. F. Erk Sun Oil CompanyJ. Imber Atlantic Richfield CompanyR. D. Irwin Honeywell, Inc
8、.E. F. Kremer E. I. duPont deNemours width x height.4) It is assumed that the instrument has its own case or shelf suitable for single mounting, unless “MULTICASE“ is checked. Shelf or separable case for multiple case mounting instrument is not included unless listed and described as an accessory.5)
9、 Enclosure class refers to composite instrument. If electrical contacts are the case they must meet this classification inherently or by reason of the enclosure. Use NEMA identification system or ISA system RP8.1.6) Specify electrical power to the entire instrument from an external source.7) For mul
10、tiple instruments list ranges on secondary sheet, but specify other chart options on primary sheet. Chart graduations assumed to be uniform unless otherwise noted. Circular charts assumed to have 24 hr/revolution speed; strip charts 3/4 in. to 1 in. per hour.8) Chart drive mechanism assumed to be sy
11、nchronous motor operating on 117V 60 Hz and suitable for ENCLOSURE CLASS specified on line 5. If the chart drive is pneumatic so state identify pneumatic pulser under options. Note deviations from standard (MFR) under notes, i.e., dual speed or special speeds.9) The scale type may be SEGMENTAL, VERT
12、ICAL, HORIZONTAL, DIAL (CIRCULAR) or other. Ranges 1, 2, 3 and 4 are used for multiple inputs. The first listed (No. 1) is assumed to be the controller input, if a controller is used.10) See explanation of terminology given on specification sheet. For further definition refer to American National St
13、andard C85.1-1963, “Terminology for Automatic Control.“ Specific ranges of control modes can be listed after “OTHER,“ if required.11) For multiple items specify on second sheet.12) If standard auto-manual switching is not known or not adequate, specify particular requirements, such as BUMPLESS, PROC
14、EDURELESS, 4-POSITION, or as required.13) Remote set point adjustment assumes full adjustment range. Specify limits if required. Under other can be noted bias or ratio.14) Specify if applicable.15) Specify if applicable.16) All input signals on multi-channel instruments assumed to be the same range
15、unless otherwise noted.17) Specify number of inputs.18) Check if power source for the loop is contained in this instrument or in some external instrument.ISA-S20-1981 1319) Form may be SPST, SPDT, DPDT or other. Rating refers to electrical rating of switch or contacts in amps.20) Specify if alarm is
16、 actuated by measured variable or by deviation from controller set point. Give contact action if single throw form.21) Specify required accessories and options, fill in number of charts. This is assured to be number of chart rolls for strip charts.22) After selection is made fill in manufacturer and
17、 specific model number.SECONDARY SHEET for listing multiple instruments. List all instruments of the same type specified on the primary sheet, with variations as shown. “Notes” refers to notes listed by number at the bottom of the sheet. Line 11 of sheet 1a is tabulated under measurement increases,
18、output tabulate increase or decrease.14 ISA-S20-1981ISA-S20-1981 15ISA Form S20.2b16 ISA-S20-19814 AnnunciatorsInstructions for ISA Forms S20.2a and 20.2b1) Write in Tag Number of entire Annunciator system.2) Omit if single unit.3) Specify cabinet mounting.4) Specify type of cabinet.5) Refers only t
19、o display and audible.6) Specify power supply required.7) Check WHITE TRANSLUCENT, or write in color of plate and engraving required. Specify window size in height x width.8) Number of independent displays in one box, or position in cabinet.9) If individual bullseyes, specify number and color requir
20、ed. If self-contained unit, specify number of normal and off-normal lights and color of each. (Example two red independent off-normal and one green common normal light.)10) Describe display if other than blacklighted nameplate or bullseye. For example; Blacklighted prism, Electrolumenescent, Two-col
21、or pneumatically operated.11) Specify type of logic unit which operates display and audible system.12) Check required location of logic components.13) Check Enclosure Class of logic components and or enclosure. General purpose relays inside an explosion proof housing, or explosion proof relays will
22、both satisfy the hazardous area classification. Use NEMA identification system or ISA system RP8.1.14) Specify voltage across contacts which actuate alarm.15) Give contact action.16) Sequential Alarm refers to “First Out“ system.17) Specify type of ring back, if applicable.18) An operational test ac
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISA201981SPECIFICATIONFORMSFORPROCESSMEASUREMENTANDCONTROLINSTRUMENTSPRIMARYELEMENTSANDCONTROLVALVES

链接地址:http://www.mydoc123.com/p-789694.html