《GME L-13A-1-2013 Radiator Durability Test (Revision 4 English German This standard may be applied only for current projects It is Superceded for all future projects and replaced by.pdf》由会员分享,可在线阅读,更多相关《GME L-13A-1-2013 Radiator Durability Test (Revision 4 English German This standard may be applied only for current projects It is Superceded for all future projects and replaced by.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、ENGINEERINGSTANDARDSEUROPETest Procedure SUPERCEDEDGME L-13A-1Radiator Durability TestNote: This standard may be applied only forcurrent projects. It is Superceded for allfuture projects and replaced by GMW14193.Khler DauererprobungHinweis: Diese Spezifikation darf nur noch frlaufende Projekte angew
2、endet werden und istfr alle zuknftigen Projekte ungltig undersetzt durch GMW14193. Copyright 2013 General Motors Corporation All Rights ReservedOriginating Department: GME Specification CenterMarch 2013 Page 1 of 4LBSP GME TP 1 11/981 Introduction 1 EinleitungNote: Nothing in the specification, howe
3、ver,supersedes applicable laws and regulationsunless a specific exemption has been obtained.Hinweis: Falls keine Ausnahmen vereinbartwurden, darf die Vorschrift keine anzuwendendenGesetze und Regelungen auer Kraft setzen.Note: In the event of a conflict between theEnglish and the domestic language,
4、the Englishlanguage shall take precedence.Hinweis: Im Falle von Unstimmigkeiten zwischendem englischen und dem landessprachlichenText, ist der englische Text ausschlaggebend.1.1 Purpose. Radiator assy. (module) durabilitytest under application of fluctuating compressiveloading with coolant additive
5、for simultaneousdynamic vibrational loading.1.1 Zweck. Dauerhaltbarkeitsprfung Khler-Zsb.(Modul) unter Druckschwellbeaufschlagung mitKhlmittelschutz bei gleichzeitiger dynamischerSchwingbeanspruchung.1.2 Foreword. Not applicable. 1.2 Vorwort. Nicht anwendbar.1.3 Applicability. For sample approval an
6、dinspection parts.1.3 Anwendbarkeit. Fr Erstbemusterung undInspektionsteile.1.4 Definitions. Not applicable. 1.4 Definitionen. Nicht anwendbar.2 References 2 ReferenzenNot applicable. Nicht anwendbar.3 Resources 3 Gerte und Einrichtungen3.1 Facilities. 3.1 Einrichtung.Test chamber, ambient temperatu
7、re up to +60C. Prfkammer, Umgebungstemperatur bis +60C3.2 Equipment. Test stand, suitable forapplication of fluctuating compressive loading anddynamic vibrational loading of radiator assembly.3.2 Ausrstung. Prfstand, geeignet fr dieDruckschwellbeaufschlagung und dynamischenSchwingbeanspruchung von K
8、hler-Zsb.3.3 Test Vehicle / Test Piece. Radiator assembly(module).3.3 Versuchsfahrzeug / Probekrper. Khler-Zsb. (Modul).4 Procedure 4 Durchfhrung4.1 Preparation. The radiator shall installed in aswinging frame with original mountings. Theradiator shall be able to move as freely in theswinging frame
9、as in the vehicle. The fan is not inoperation. (Fig. 1)4.1 Vorbereitung. Der Khler wird in einenSchwingrahmen mit Original-Lagerung eingebaut.Der Khler mu sich im Schwingrahmen,entsprechend wie im Fahrzeug, frei bewegenknnen. Das Geblse ist nicht im Betrieb. (Abb. 1)SUPERCEDED GME L-13A-1 GM ENGINEE
10、RING STANDARD EUROPE Copyright 2013 General Motors Corporation All Rights ReservedPage 2 of 4 March 2013LBSP GME TP G 11/984.2 Conditions. 4.2 Bedingungen.4.2.1 Environmental Conditions. Thetemperature in the testing chamber shall be+55C 5 K.4.2.1 Umgebungsbedingungen. In der Prf-kammer soll die Tem
11、peratur +55C 5 Kbetragen.4.2.2 Pressurisation Parameters.No. of pressure changes: 100 000Pressure cycles: 8 pressure changes per minSequence of pressure rises:continuous9 pressure changes of (70 . 100) 5 kPa1 pressure change of (70 . 200) 5 kPaPressure rise: sinusoidalFlow rate: 30 l /min min.Coolan
12、t medium: coolant additive for theengine / radiator systemaccording to vehiclespecificationCoolant temperature: +104C 2 K4.2.2 Parameter fr die Druckbeaufschlagung.Druckwechselanzahl: 100 000Druckzyklen: 8 Druckwechsel pro minReihenfolge der Druckanstiege:kontinuierlich9 Druckwechsel von (70 . 100)
13、5 kPa1 Druckwechsel von (70 . 200) 5 kPaDruckanstieg: sinusfrmigDurchflumenge: 30 l /min min.Khlmittelmedium: Khlschutzmittel fr dasMotorkhlsystementsprechendFahrzeugspezifikationKhlmitteltemperatur: +104C 2 K4.2.3 Vibrational Loading ParametersExcitation direction: verticalTest frequency: (31 2) Hz
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMEL13A12013RADIATORDURABILITYTESTREVISION4ENGLISHGERMANTHISSTANDARDMAYBEAPPLIEDONLYFORCURRENTPROJECTSITISSUPERCEDEDFORALLFUTUREPROJECTSANDREPLACEDBYPDF

链接地址:http://www.mydoc123.com/p-755660.html