《ETSI EN 300 119-7-2015 Environmental Engineering (EE) European telecommunication standard for equipment practice Part 7 Engineering requirements for Subracks in harmonized racks an_1.pdf》由会员分享,可在线阅读,更多相关《ETSI EN 300 119-7-2015 Environmental Engineering (EE) European telecommunication standard for equipment practice Part 7 Engineering requirements for Subracks in harmonized racks an_1.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、 ETSI EN 300 119-7 V1.1.1 (2015-02) Environmental Engineering (EE); European telecommunication standard for equipment practice; Part 7: Engineering requirements for Subracks in harmonized racks and cabinets with extended features EUROPEAN STANDARD ETSI ETSI EN 300 119-7 V1.1.1 (2015-02) 2Reference D
2、EN/EE-0058 Keywords environment, equipment practice, rack ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-Prfecture de Grasse (06) N 7803/88 Import
3、ant notice The present document can be downloaded from: http:/www.etsi.org/standards-search The present document may be made available in electronic versions and/or in print. The content of any electronic and/or print versions of the present document shall not be modified without the prior written a
4、uthorization of ETSI. In case of any existing or perceived difference in contents between such versions and/or in print, the only prevailing document is the print of the Portable Document Format (PDF) version kept on a specific network drive within ETSI Secretariat. Users of the present document sho
5、uld be aware that the document may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at http:/portal.etsi.org/tb/status/status.asp If you find errors in the present document, please send your comment to one of the following se
6、rvices: https:/portal.etsi.org/People/CommiteeSupportStaff.aspx Copyright Notification No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm except as authorized by written permission of ETSI. The content of the PDF version
7、shall not be modified without the written authorization of ETSI. The copyright and the foregoing restriction extend to reproduction in all media. European Telecommunications Standards Institute 2015. All rights reserved. DECTTM, PLUGTESTSTM, UMTSTMand the ETSI logo are Trade Marks of ETSI registered
8、 for the benefit of its Members. 3GPPTM and LTE are Trade Marks of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. GSM and the GSM logo are Trade Marks registered and owned by the GSM Association. ETSI ETSI EN 300 119-7 V1.1.1 (2015-02) 3Contents Intellectual
9、Property Rights 4g3Foreword . 4g3Modal verbs terminology 5g31 Scope 6g32 References 6g32.1 Normative references . 6g32.2 Informative references 6g33 Abbreviations . 7g34 Dimensions for subracks 7g35 Accessibility . 7g36 Weight 7g36.1 Unequipped subrack . 7g36.2 Equipped subrack . 7g3Annex A (informa
10、tive): Illustrative figures 9g3Annex B (informative): Bibliography . 12g3History 13g3ETSI ETSI EN 300 119-7 V1.1.1 (2015-02) 4Intellectual Property Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertaining to these essential IPR
11、s, if any, is publicly available for ETSI members and non-members, and can be found in ETSI SR 000 314: “Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are ava
12、ilable on the ETSI Web server (http:/ipr.etsi.org). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are
13、, or may be, or may become, essential to the present document. Foreword This European Standard (EN) has been produced by ETSI Technical Committee Environmental Engineering (EE). The present document is part 7 of a multi-part deliverable aimed at setting out, on a common basis, the engineering requir
14、ements for telecommunication practice, for housing equipment forming part of a public telecommunications network. ETSI EN 300 119-1 i.1 is a general introduction and explains the terminology used. ETSI EN 300 119-2 i.2 specifies the engineering requirements for racks and cabinets and ETSI EN 300 119
15、-3 i.3 specifies the engineering requirements for miscellaneous racks and cabinets. ETSI EN 300 119-5 i.5 covers the preferred thermal management solutions for subracks, racks/cabinets and miscellaneous racks/cabinets installed indoors in restricted access locations, for the removal of heat dissipat
16、ed by one or more subracks in an rack complying to the requirements of this multi-part standard. The present document specifies the engineering requirements for subracks mounted in harmonized racks and cabinets with extended features. The present document applies to all telecommunications equipment
17、forming part of the public telecommunications network. The present document, ETSI EN 300 119-7, is defining extension to the existing parts of the standard to harmonize dimensions and to extend rack installation capabilities. These extended features are: mounting bracket depth adjustment only on sub
18、rack level (as normally done in many other standardized equipment practices; see 19 inches) common position of mounting brackets for both 300 mm and 600 mm depth recessed subrack mounting plane compared to ETSI EN 300 119-3 i.3 and ETSI EN 300 119-4 i.4 to allow more room for cable management and be
19、tter cable access from front/rear aisle design subrack mounting plane in a manner so that not only 600 mm deep rack is a earthquake proof design but also the 300 mm rack (600 mm: 7 inches deep upright; 300 mm 3,5 inches deep upright; commonality with EIA rack standard for SNBF) make ETSI mounting pr
20、inciple similar to SNBF (5 inches deep upright) which is used in USA telecommunication offices to gain more commonality for international markets define extra front side cabling space for accommodating optical and electrical I/O cables Illustrative figures are contained in annex A. The present docum
21、ent is part 7 of a multi-part deliverable. Full details of the entire series can be found in part 1 i.1. ETSI ETSI EN 300 119-7 V1.1.1 (2015-02) 5National transposition dates Date of adoption of this EN: 19 February 2015 Date of latest announcement of this EN (doa): 31 May 2015 Date of latest public
22、ation of new National Standard or endorsement of this EN (dop/e): 30 November 2015 Date of withdrawal of any conflicting National Standard (dow): 30 November 2015 Modal verbs terminology In the present document “shall“, “shall not“, “should“, “should not“, “may“, “may not“, “need“, “need not“, “will
23、“, “will not“, “can“ and “cannot“ are to be interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of provisions). “must“ and “must not“ are NOT allowed in ETSI deliverables except when used in direct citation. ETSI ETSI EN 300 119-7 V1.1.1 (2015-02) 61 Sc
24、ope The present document details requirements for subracks for use in harmonized racks/cabinets, as described in ETSI EN 300 119-6 i.6. The subrack will normally be supplied as a fully assembled structure, unequipped, partially equipped or fully equipped with plug-in units, etc. 2 References 2.1 Nor
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ETSIEN30011972015ENVIRONMENTALENGINEERINGEEEUROPEANTELECOMMUNICATIONSTANDARDFOREQUIPMENTPRACTICEPART7ENGINEERINGREQUIREMENTSFORSUBRACKSINHARMONIZEDRACKSAN_1PDF

链接地址:http://www.mydoc123.com/p-727874.html