EN 61000-4-21-2011 en Electromagnetic compatibility (EMC) - Part 4-21 Testing and measurement techniques - Reverberation chamber test methods《电磁兼容性(EMC) 第4-21部分 试验和测量技术 混响室试验方法》.pdf
《EN 61000-4-21-2011 en Electromagnetic compatibility (EMC) - Part 4-21 Testing and measurement techniques - Reverberation chamber test methods《电磁兼容性(EMC) 第4-21部分 试验和测量技术 混响室试验方法》.pdf》由会员分享,可在线阅读,更多相关《EN 61000-4-21-2011 en Electromagnetic compatibility (EMC) - Part 4-21 Testing and measurement techniques - Reverberation chamber test methods《电磁兼容性(EMC) 第4-21部分 试验和测量技术 混响室试验方法》.pdf(112页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationElectromagnetic compatibility(EMC)Part 4-21: Testing and measurement techniques Reverberation chamber test methodsBS EN 61000-4-21:2011National forewordThis British Standard is t
2、he UK implementation of EN 61000-4-21:2011. It is identical to IEC 61000-4-21:2011. It supersedes BS EN 61000-4-21:2003 which will be withdrawn on 3 March 2014.The UK participation in its preparation was entrusted by Technical Committee GEL/210, EMC - Policy committee, to Subcommittee GEL/210/12, EM
3、C basic, generic and low frequency phenomena Standardization.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. B
4、SI 2011ISBN 978 0 580 64788 8 ICS 33.100.10; 33.100.20Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 July 2011.Amendments issued since publicationAmd. No. Da
5、te Text affectedBRITISH STANDARDBS EN 61000-4-21:2011EUROPEAN STANDARD EN 61000-4-21 NORME EUROPENNE EUROPISCHE NORM April 2011 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management
6、Centre: Avenue Marnix 17, B - 1000 Brussels 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61000-4-21:2011 E ICS 33.100.10; 33.100.20 Supersedes EN 61000-4-21:2003English version Electromagnetic compatibility (EMC) - Part 4-
7、21: Testing and measurement techniques - Reverberation chamber test methods (IEC 61000-4-21:2011) Compatibilit lectromagntique (CEM) - Partie 4-21: Techniques dessai et de mesure - Mthodes dessai en chambre rverbrante (CEI 61000-4-21:2011) Elektromagnetische Vertrglichkeit (EMV) - Teil 4-21: Prf- un
8、d Messverfahren - Verfahren fr die Prfung in der Modenverwirbelungskammer (IEC 61000-4-21:2011) This European Standard was approved by CENELEC on 2011-03-03. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
9、 the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French,
10、 German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bul
11、garia, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 610
12、00-4-21:2011EN 61000-4-21:2011 - 2 - Foreword The text of document 77B/619/CDV, future edition 2 of IEC 61000-4-21, prepared by SC 77B, High frequency phenomena, of IEC TC 77, Electromagnetic compatibility, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61000-4-21 o
13、n 2011-03-03. This European Standard supersedes EN 61000-4-21:2003. EN 61000-4-21:2011 includes the following significant technical changes with respect to EN 61000-4-21:2003: In Clause 8, the use and specifications of E-field probes for application to reverberation chambers has been added. Addition
14、al Notes refer to general aspects and procedures of probe calibrations. The specified range for linearity of the probe response is larger and covers an asymmetric interval compared to that for use in anechoic chambers (see Annex I of EN 61000-4-3), because the fluctuations of power and fields in rev
15、erberation chambers exhibit a larger dynamic range, and the chamber validation procedure is based on using maximum field values, as opposed to the field itself or its average value, respectively. In Annex A, additional guidance and clarifications on the use of reverberation chambers at relatively lo
16、w frequencies of operation (i.e., close to the lowest usable frequency of a given chamber) are given, and its implications on the estimation of field uncertainty are outlined. Guidelines on cable-layout have been added. A rationale has been added that explains the relaxation of the field uniformity
17、requirement below 400 MHz, being a compromise between scientific-technical and economical reasons when using chambers around 100 MHz. A first-order correction for the threshold value of the correlation coefficient at relatively low numbers of tuner positions has been added. Issues regarding the use
18、of non-equidistant tuner positions at low frequencies are discussed in an additional note. In Annex B, symmetric location of the field probes when the chamber exhibits cylindrical symmetry has been disallowed, as such placement could otherwise yield a false indication of field uniformity and chamber
19、 performance at different locations. The difference between start frequency for chamber validation and lowest test frequency has been clarified. The tuner sequencing for chamber validation and testing is now specified to be equal in both cases. In sample requirements for chamber validation, emphasis
20、 is now on the required minimum number of independent tuner steps to be used, whereas the minimum recommended number of samples per frequency interval has been replaced with he number of independent samples that the tuner can provide per frequency, for use in case when the chamber validation fails f
21、or the required minimum number. Annex C now contains more quantitative guidance on the setting of the maximum permissible stirring speeds that warrant quasi-static conditions of operation for chamber validation and testing. Consideration is given to all characteristic time scales of all components o
22、r subsystems of a measurement or test. Specific issues relating to chamber validation, immunity testing and bandwidth are addressed. Particular requirements for field probes when used with mode stirred operation are listed. In Annex D, a requirement for the EUT and equipment not to occupy more than
23、8 % of the total chamber volume in immunity testing has been added. The maximum number of frequency points and the formula to calculate these points have been generalized. A mandatory specification for including the measurement equipment, test plan and cable layout in the test report has been added
24、to resolve any dispute in case of discrepancies, particularly for low-frequency immunity testing. Annex E has been extended with further guidance on the value of EUT directivity to be used in the estimation of radiated power and field. Extended estimates have been added for the maximum directivity o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN610004212011ENELECTROMAGNETICCOMPATIBILITYEMCPART421TESTINGANDMEASUREMENTTECHNIQUESREVERBERATIONCHAMBERTESTMETHODS

链接地址:http://www.mydoc123.com/p-719281.html