EN 60094-5-1993 en Magnetic Tape Sound Recording and Reproducing Systems Part 5 Electrical Magnetic Tape Properties (Incorporates Amendment A1 1996)《磁带录音和复制装置 第5部分 磁带的电特性 替代HD 311 .pdf
《EN 60094-5-1993 en Magnetic Tape Sound Recording and Reproducing Systems Part 5 Electrical Magnetic Tape Properties (Incorporates Amendment A1 1996)《磁带录音和复制装置 第5部分 磁带的电特性 替代HD 311 .pdf》由会员分享,可在线阅读,更多相关《EN 60094-5-1993 en Magnetic Tape Sound Recording and Reproducing Systems Part 5 Electrical Magnetic Tape Properties (Incorporates Amendment A1 1996)《磁带录音和复制装置 第5部分 磁带的电特性 替代HD 311 .pdf(38页珍藏版)》请在麦多课文档分享上搜索。
1、 STD-BSI BS EN bOO74-5-ENGL 1994 Lb24bbS 0587784 487 H BRITISH STANDARD Magnetic tape sound recording and reproducing systems Part 5. Specification for electrical magnetic tape properties The European Standard EN 6094-6 : 1993 with the incorporation of amendment Al : 1996 has the status of a British
2、 Standard ICs 33.160.30 BS EN 60094-5 : 1994 BS 6288 : Part 6 : 1989 Incorpomting Amend- amendment Al was approved by CENELEC on 1996-03-06. CENELEC members are bound to comply with the CENKENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a n
3、ational standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A versio
4、n in any other language made by transhion under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national elech-otechnical committees of Auslxh, Belgium, Denmark, Finland, kance,
5、 Germany, Greece, Iceland, Ireland, Iaiy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central
6、 Secretariat: rue de Stassart 36, B-1060 Brussels O 1993 Copyright reserved to CENELEC members Ref. No. EN 600942) : 1993 +Al : 1996 E STD-BSI BS EN b0074-5-EEL 377q Lb24bb7 5A78A O22 = EN6009416:1993 Issue 1, February 1997 -latest date of pubicaon of anidenticalnalionalstmdard (dop) 1994-1Qol -late
7、st date of withdrawal of dwndhal- (dow) - Annexes designated nonnative are part of the body of . thestandardhInthisdard,annexZAisnonnative. Foreword As a umeqwme of the IEC-CENELEC Agreement, HD311.6Sl: l this may be separately quoted in the manufacturers published data, together with any relevant t
8、est results andlor curves. I 4.76 IEC I 4.76 IECII 4.76 IECIII 4.76 IEC IV 4.76 - 9.53 - 19.0s - TABLE IV Y348M UWW CS301 MJ507A cmz C2MZ C2MZ Table of maximum output levels specijied for domestic I E C primary reference tapes width 3.81 6.31 6.31 * = not specified nie alternative nferencc bias meth
9、od shall be used according to 2.6.lb). The amount below the obtainable maximum at 6.3 kHz output shall be 4 dB at 9.5 ds. Nntr. - 3.81 mm widc domestic tape types IEC 1. II. 111 and IV arc described in Table V. Il SECTION THREE - PARAMETERS TO BE MEASURED Mcasirrrrncni cotiditions : al For the purpo
10、se of this standard. ali professional tapes shall be measured using their own value of conventional test bias. In addition. measurements may be made using a value of reference bias derived from the relevant reference tape. h) For the purpose of this standard. all domestic tapes shall be measured usi
11、ng conventional test bias. IEC page 21) STD-BSI BS EN bOOS4-5-ENGL 1994 m Lb24bb9 0587777 035 Issue 2, February 1997 Page 9 EN 60094-6 : 1993 However if additional optional measurements are made using optimum bias for the tape under test, the bias value shall be determined from the bias current whic
12、h will produce the same diffeience between its maximum output levels at 10 kHz and 315 Hz (1 kHz for 19.05 ds tape speed) as that specified for the relevant pimary reference tape (see Table IV). This bias value shall be expressed in terms of bias ratio (see Subclause 3.1). It should be noted that th
13、e specified difference between the maximum output levels shall be determined with measuring equipment having accurately calibrated electrical characteristics : 1) The amplituddfrequency response ” section of the calibration tape. used for adjusting the reproducing chain shall not vary from the absol
14、ute value, or if there is any deviation this shall be known. 2) The reference level contained on the calibration tape used shall not vary from the absolute value, or if there is any deviation, this shall be known. Nofe. - The absolute values for 3.81 mm wide calibration tapes arc represented by the
15、calibration tapes b) if three drop-outs with h 3 2 occur within 1 s, three points shall be added to the h, value ; c) if four or more dropouts with h Z 2 occur within 1 s, four points shall be added to the h , value. nie sum of the resulting h, values of Items i), ii) and iii) shall be expressed in
16、four categories as follows : - category 1: 2 S h, S 4 - category 2: 5 S h, d 8 - category 3: 9 d h, s 12 - category 4: 13 d h, The audiofrequency current in the recording head shall be as specified in the method of Sub- clause 3.3. Measurement of drop-out annoyance shall be made at the output of the
17、 replay chain, using suitable dropout annoyance measuring equipment (see Appendix B). Dropout annoyance shall be measured using a frequency of 3 150 Hz and the value of conven- tional test bias for the tape under test. The test shall be camed out for 50 successive samplings of M s at the rated tape
18、speed. Measurements at the same wavelength, using a multiple of the rated speeds. may be made with suitable equipment. Tracks to be used for drop-out annoyance: a For professional tapes 6.30 mm wide Measurement of dropout annoyance shall be camed out on both tracks using the head configuration speci
19、fied in table II (see Sub-clause 2.2). IEX page 451 20 STD-BSI BS EN bOOSY-5-ENGL 1794 Lb2qbbS 0587830 3T BS6288 : Part5 : 1989 6) For domestic mpes 6.30 mm and 3.81 mm wide Measurement of drop-out annoyance shall be camed out on both outer and one inner track using the head configuration specified
20、in Table 11. Measurements : a) For professional tapes 6.30 mm wide Drop-out annoyance should be measured as indicated in Table VI. b) For domestic tapes 6.30 mm wide Drop-out annoyance should be measured as indicated in Table WI. c) For domestic tapes 3.81 mm wide Drop-out annoyance should be measur
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN6009451993ENMAGNETICTAPESOUNDRECORDINGANDREPRODUCINGSYSTEMSPART5ELECTRICALMAGNETICTAPEPROPERTIESINCORPORATESAMENDMENTA11996

链接地址:http://www.mydoc123.com/p-717605.html