EN 2591-226-2007 en Aerospace series - Elements of electrical and optical connection - Test methods - Part 226 Corona level《航空航天系列 电气和光学连接元件的试验方法 第226部分 电晕等级》.pdf
《EN 2591-226-2007 en Aerospace series - Elements of electrical and optical connection - Test methods - Part 226 Corona level《航空航天系列 电气和光学连接元件的试验方法 第226部分 电晕等级》.pdf》由会员分享,可在线阅读,更多相关《EN 2591-226-2007 en Aerospace series - Elements of electrical and optical connection - Test methods - Part 226 Corona level《航空航天系列 电气和光学连接元件的试验方法 第226部分 电晕等级》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 2591-226:2007Aerospace series Elements of electrical and optical connection Test methods Part 226: Corona levelICS 49.060g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37
2、g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 2591-226:2007This British Standard was published under the authority of the Standards Policy and Strategy Committee on 29 February 2008 BSI 2008ISBN 978 0 580 56480 2National forewordThis British Standard is the UK implementation of EN 2591-226:2007.T
3、he UK participation in its preparation was entrusted by Technical Committee ACE/6, Aerospace avionic electrical and fibre optic technology, to Panel ACE/6/-/3, Aerospace Connectors.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does
4、 not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Amendments/corrigenda issued since publicationDate CommentsEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE
5、 NORMEN 2591-226December 2007ICS 49.060English VersionAerospace series - Elements of electrical and optical connection- Test methods - Part 226: Corona levelSrie arospatiale - Organes de connexion lectrique etoptique - Mthodes dessais - Partie 226: Seuil dedcharge CoronaLuft- und Raumfahrt - Elektri
6、sche und optischeVerbindungselemente - Prfverfahren - Teil 226:CoronaspannungThis European Standard was approved by CEN on 27 April 2006.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national
7、standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any oth
8、er language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, F
9、inland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOM
10、ITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2007 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 2591-226:2007: E2 Contents Page Foreword3 1 Scope 4 2 Normative references 4 3 Preparation of specimens.4 4 Me
11、thod 5 5 Requirements.5 EN 2591-226:20073 Foreword This document (EN 2591-226:2007) has been prepared by the Aerospace and Defence Industries Association of Europe - Standardization (ASD-STAN). After enquiries and votes carried out in accordance with the rules of this Association, this Standard has
12、received the approval of the National Associations and the Official Services of the member countries of ASD, prior to its presentation to CEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by June
13、2008, and conflicting national standards shall be withdrawn at the latest by June 2008. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights
14、. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy
15、, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 2591-226:20074 1 Scope This standard specifies a test method to determine no sustained Corona discharge on a mated pair of connectors. It
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN25912262007ENAEROSPACESERIESELEMENTSOFELECTRICALANDOPTICALCONNECTIONTESTMETHODSPART226CORONALEVEL 航空航天

链接地址:http://www.mydoc123.com/p-710127.html