ECA EIA-364-04B-2015 TP-04B Normal Force Test Procedure for Electrical Connectors.pdf
《ECA EIA-364-04B-2015 TP-04B Normal Force Test Procedure for Electrical Connectors.pdf》由会员分享,可在线阅读,更多相关《ECA EIA-364-04B-2015 TP-04B Normal Force Test Procedure for Electrical Connectors.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、 EIA STANDARD TP-04B Normal Force Test Procedure for Electrical Connectors EIA-364-04B (Revision of EIA-364-04A) August 2015 Electronic Components Industry Association EIA-364-04B ANSI/EIA-364-04B-2015 Approved: August 26, 2015 NOTICE EIA Engineering Standards and Publications are designed to serve
2、the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standar
3、ds and Publications shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than ECIA members, wh
4、ether the standard is to be used either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does not assume any liability to any patent owner, nor does it assume any ob
5、ligation whatever to parties adopting the Standard or Publication. This EIA Standard is considered to have International Standardization implications, but the International Electrotechnical Commission activity has not progressed to the point where a valid comparison between the EIA Standard and the
6、IEC document can be made. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of
7、regulatory limitations before its use. (From Standards Proposal No. 5345.02 formulated under the cognizance of the CE-2.0 Committee on EIA National Connector and Sockets Standards.) Published by Electronic Components Industry Association 2015 EIA Standards see figure 1. 2.1.1.3.1.2 The tip of the te
8、st probe shall be either flat or curved. If a flat tip is used, the width of the flat shall be 0.127 millimeter (0.005 inch) minimum but shall not exceed the width (W) of the contact tine. If curved, the radius shall be equal to or less than the internal radius of the tine; see figures 1 and 2). 2.1
9、.1.3.2 Flat, concave, dimpled or crowned contacts The test probe mating surface shall be flat with a width not to be less than 75% of the total width of the contact element being tested; see figure 3). 2.1.1.3.2.1 The length of the test probe contacting surface shall be of sufficient length to avoid
10、 improper interference and shall maintain proper contact with the test sample during the deflection cycle. 2.1.1.3.2.2 The test probe contacting surface shall be polished and free of ridges, tool marks or burrs. 2.1.1.3.2.3 The test probe shall be axially positioned relative to the contact element t
11、o be tested so as not to cause eccentric or torsional loading of the beam beyond that which may be normal to its operational mode. 2.1.1.4 A linear transducer shall be used for determining the distance deflected with a non-linearity of 1%. 2.1.1.5 An X-Y recording instrument shall be used with a cap
12、ability of recording with a precision of 1%. 2.1.1.6 When a force readout instrument is used, it shall be capable of reading the force to an accuracy of 2%. 2.1.1.7 The equipment shall be so arranged to allow the contact to be deflected manually or through a driving mechanism to predetermined levels
13、 as required. The equipment shall be capable of producing a smooth axial displacement at a controlled rate between 0.254 mm and 25.4 mm (0.01 inch and 1.0 inch) per minute 2.1.1.3.1 Convex contacts (split cylinder) EIA-364-04B Page 3 2.1.1.8 Due to various connector configurations and contact design
14、s, different fixturing techniques may be required. Some designs allow individual contacts to float within the connector housing or the deflecting elements may be contained internal to an outer contact shell. It may be necessary to remove these contacts from the connector housing for testing. Special
15、 fixturing techniques or instructions for “loose” contact testing shall be indicated in the referencing document. 2.1.2 Test method B 2.1.2.1 Normal force gage similar in geometry to the mating part and capable of measuring the normal force without altering the working contact interface characterist
16、ics. The gage shall provide a linear output with relative indifference to the position of the load within an accuracy of 1.5%. 2.1.2.2 Force readout instrument capable of reading the force to an accuracy of .5%. 2.1.2.3 Weights certified within the range of normal force values being measured. 2.1.2.
17、4 Calibration fixture capable of positioning the certified weights on the center of the normal force gage sensing beam. 3 Test specimen 3.1 Description Test specimen shall consist of contacts or connector assemblies. 3.2 Preparation 3.2.1 Contacts or connector assemblies shall be prepared prior to p
18、lacement in the housing fixture. 3.2.1.1 In the case of connector assemblies, housings may be modified if access is not possible and normal force characteristics are not affected. The natural locking and preload features of the contact/housing system shall not be disturbed. 3.2.1.2 In the case of mu
19、ltiple tine contacts, all tines not to be tested which may interfere with the test probes, shall be removed if the tine to be tested is not affected. 3.2.1.3 Connector assemblies which are normally soldered to printed circuit boards or held in place thereof shall be tested in that state. 3.2.2 Conta
20、cts or connector assemblies as prepared shall be placed in the holding fixture. 3.2.2.1 Placement of connector assemblies in the fixture shall be accomplished so as not to disturb the natural connector locking features, position of the contact relative to its housing, or modify the natural beam defl
21、ection characteristics. EIA-364-04B Page 4 3.2.2.2 Placement of loose contacts in the fixture shall be accomplished by having said fixture grip the contact in the area which is normally fixed in the application without modifying the natural beam deflection characteristics. 4 Test procedure 4.1 Test
22、method A Unless otherwise specified, the following procedures shall be utilized in the determination of permanent set when required. 4.1.1 Normal force/deflection characteristics 4.1.1.1 It is recommended that the normal force/deflection characteristics for contacts tested be plotted on the same gra
23、ph with appropriate identification. 4.1.1.2 Unless otherwise specified, the graphics shall indicate the deflection on the horizontal axis and normal force on the vertical axis; see figure 4. 4.1.1.3 Applicable measuring equipment shall be calibrated (i.e. load cell, displacement devices and X-Y reco
24、rder). 4.1.1.4 Measure contact gap to determine the amount of deflection required to attain the contact normal force for minimum, nominal and maximum mating elements. 4.1.1.5 The contact, connector assembly or test probe shall be moved until it registers a force not to exceed 0.03 Newton (formerly s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECAEIA36404B2015TP04BNORMALFORCETESTPROCEDUREFORELECTRICALCONNECTORSPDF

链接地址:http://www.mydoc123.com/p-704180.html