《DLA SMD-5962-96730 REV C-2008 MICROCIRCUIT HYBRID LINEAR +5 VOLT AND PLUS MINUS 12 VOLT TRIPLE CHANNEL DC DC CONVERTER《DC DC变换器三通道+5伏和±12伏线性混合微电路》.pdf》由会员分享,可在线阅读,更多相关《DLA SMD-5962-96730 REV C-2008 MICROCIRCUIT HYBRID LINEAR +5 VOLT AND PLUS MINUS 12 VOLT TRIPLE CHANNEL DC DC CONVERTER《DC DC变换器三通道+5伏和±12伏线性混合微电路》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Table I; Changed either the min or max limits for VRIP, VRLINE, VRLOAD, IIN, IRIP, Eff, PD, FS, VTLOAD, and TTLOADtests. Table I; removed the condition LIN= 5.5 H for the input ripple test. Figure 1; case outline Z, changed the figure to show the
2、 flange is no longer brazed on the package. Editorial changes throughout. -sld 02-02-13 Raymond Monnin B Correct paragraphs 4.2.a.2 and 4.3.3.b.2. 05-06-08 Raymond Monnin C In section 1.3; Add “Continuous” after Input voltage range, and also add Input voltage range transient 80 V for 120 ms. 08-03-2
3、4 Robert M. Heber REV SHEET REV SHEET REV STATUS REV C C C C C C C C C C C C OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 11 12 PMIC N/A PREPARED BY Gary Zahn DEFENSE SUPPLY CENTER COLUMBUS STANDARD MICROCIRCUIT DRAWING CHECKED BY Michael C. Jones COLUMBUS, OHIO 43218-3990 http:/www.dscc.dla.mil THIS DRAWIN
4、G IS AVAILABLE FOR USE BY ALL DEPARTMENTS APPROVED BY Ray Monnin MICROCIRCUIT, HYBRID, LINEAR, +5 VOLT AND 12 VOLT, TRIPLE CHANNEL, DC/DC CONVERTER AND AGENCIES OF THE DEPARTMENT OF DEFENSE DRAWING APPROVAL DATE 99-11-29 AMSC N/A REVISION LEVEL C SIZE A CAGE CODE 67268 5962-96730 SHEET 1 OF 12 DSCC
5、FORM 2233 APR 97 5962-E218-08 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-96730 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL C SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope.
6、This drawing documents five product assurance classes as defined in paragraph 1.2.3 and MIL-PRF-38534. A choice of case outlines and lead finishes which are available and are reflected in the Part or Identifying Number (PIN). When available, a choice of radiation hardness assurance levels are reflec
7、ted in the PIN. 1.2 PIN. The PIN shall be as shown in the following example: 5962 - 96730 01 H X X Federal RHA Device Device Case Lead stock class designator type class outline finish designator (see 1.2.1) (see 1.2.2) designator (see 1.2.4) (see 1.2.5) / (see 1.2.3) / Drawing number 1.2.1 Radiation
8、 hardness assurance (RHA) designator. RHA marked devices shall meet the MIL-PRF-38534 specified RHA levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device. 1.2.2 Device type(s). The device type(s) identify the circuit function as follows: Device type Ge
9、neric number Circuit function 01 MHV28512T/883, MHV28512TF/883 DC-DC converter, 15 W, +5 V and 12 V outputs 1.2.3 Device class designator. This device class designator shall be a single letter identifying the product assurance level. All levels are defined by the requirements of MIL-PRF-38534 and re
10、quire QML Certification as well as qualification (Class H, K, and E) or QML Listing (Class G and D). The product assurance levels are as follows: Device class Device performance documentation K Highest reliability class available. This level is intended for use in space applications. H Standard mili
11、tary quality class level. This level is intended for use in applications where non-space high reliability devices are required. G Reduced testing version of the standard military quality class. This level uses the Class H screening and In-Process Inspections with a possible limited temperature range
12、, manufacturer specified incoming flow, and the manufacturer guarantees (but may not test) periodic and conformance inspections (Group A, B, C and D). E Designates devices which are based upon one of the other classes (K, H, or G) with exception(s) taken to the requirements of that class. These exce
13、ption(s) must be specified in the device acquisition document; therefore the acquisition document should be reviewed to ensure that the exception(s) taken will not adversely affect system performance. D Manufacturer specified quality class. Quality level is defined by the manufacturers internal, QML
14、 certified flow. This product may have a limited temperature range. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-96730 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL C SHEET 3 DSCC
15、 FORM 2234 APR 97 1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Package style X See figure 1 10 Dual-in-line Z See figure 1 10 Flanged package 1.2.5 Lead finish. The lead finish shall be as specified in MI
16、L-PRF-38534. 1.3 Absolute maximum ratings. 1/ Input voltage range continuous -0.5 V dc to +50 V dc Input voltage range transient . 80 V for 120 ms Power dissipation (PD) . 9.5 W Output power 2/ . 15.3 W Lead temperature (soldering, 10 seconds). +300C Storage temperature range -65C to +150C 1.4 Recom
17、mended operating conditions. Input voltage range +16 V dc to +50 V dc Case operating temperature range (TC). -55C to +125C 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part of this drawing to the extent s
18、pecified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38534 - Hybrid Microcircuits, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcir
19、cuits. MIL-STD-1835 - Interface Standard for Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit Drawings. (Copies of these documents are available online at http:/assist.daps.dla.mil/quicksea
20、rch/ or http:/assist.daps.dla.mil or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text of this drawing takes prece
21、dence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 1/ Stresses above the absolute maximum ratings may cause permanent damage to the device, except for input voltage transients up to 80 volts for no more than 120 millise
22、conds. Extended operation at the maximum levels may degrade performance and affect reliability. 2/ Derate output power linearly above case temperature (TC) of +125C to 0 W at +130C. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUI
23、T DRAWING SIZE A 5962-96730 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL C SHEET 4 DSCC FORM 2234 APR 97 3. REQUIREMENTS 3.1 Item requirements. The individual item performance requirements for device classes D, E, G, H, and K shall be in accordance with MIL-PRF-38534. Comp
24、liance with MIL-PRF-38534 may include the performance of all tests herein or as designated in the device manufacturers Quality Management (QM) plan or as designated for the applicable device class. The manufacturer may eliminate, modify or optimize the tests and inspections herein, however the perfo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLASMD596296730REVC2008MICROCIRCUITHYBRIDLINEAR5VOLTANDPLUSMINUS12VOLTTRIPLECHANNELDCDCCONVERTERDCDC

链接地址:http://www.mydoc123.com/p-701054.html