1、AMSC N/A FSC 5950 INCH-POUND MIL-PRF-27/351E 25 July 2008 SUPERSEDING MIL-PRF-27/351D 22 January 1992 PERFORMANCE SPECIFICATION SHEET TRANSFORMERS, POWER, 25 VOLTAMPERES, 400 HZ This specification is approved for use by all Depart- ments and Agencies of the Department of Defense. The complete requir
2、ements for procuring the transformer described herein shall consist of this document and the latest issue of specification MIL-PRF-27. NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information. 3. Dimensional tolerance shall be .03 (0.8 mm) unless otherwise specifie
3、d. 4. Marking shall be on the top case. 5. Terminals shall be identified by numbers 1 through 5 marked on the top of case above each terminal. 6. Secondary electrical values shall be marked as specified in table I, as applicable. 7. The insert shall be 5 full threads minimum. 8. Terminal spacing is
4、.35 .03 (8.9 0.8 mm). FIGURE 1. Dimensions and configuration. INCHES MM .063 .15 .164 .23 1.00 1.75 1.60 3.8 4.17 5.8 25.4 44.5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-27/351E 2 REQUIREMENTS: (When numbers in parentheses i.e (1-2) are
5、 used, they indicate the winding and the extreme terminals of the winding.) Electrical ratings: See table I. Primary voltage (1-2): 115 volts 10 percent, 400 hertz 5 percent. Working voltage: 357 volts, peak. Design and construction: Dimensions and configuration: See figure 1. Weight: .33 pound, max
6、imum. Duty cycle: Continuous. Case: Epoxy fiberglass or diallyl phthalate. Altitude: 70,000 feet, maximum. Operating temperature range: -55C to +130C. Terminals: Feedthrough. Terminal height: 0.23 inch, maximum. Terminal strength: MIL-STD-202, method 211, test condition A, 5 pounds. Dielectric withs
7、tanding voltage: At sea level: 1000 volts, rms. At reduced barometric pressure: 1.25 times the peak working voltage specified. Electrical characteristics: No load: With 115 volts, 400 hertz across (1-2); current in (1-2) shall not exceed 25 milliamperes rms. Rated load: With 115 volts, 400 hertz acr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF27351E2008TRANSFORMERSPOWER25VOLTAMPERES400HZ25 伏安 400 赫兹 变压器 PDF

链接地址:http://www.mydoc123.com/p-692738.html