DLA MIL-DTL-641 F-2013 JACKS TELEPHONE GENERAL SPECIFICATION FOR.pdf
《DLA MIL-DTL-641 F-2013 JACKS TELEPHONE GENERAL SPECIFICATION FOR.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-DTL-641 F-2013 JACKS TELEPHONE GENERAL SPECIFICATION FOR.pdf(21页珍藏版)》请在麦多课文档分享上搜索。
1、AMSC N/A FSC 5935 MIL-DTL-641F 09 September 2013 SUPERSEDING MIL-J-641E 26 February 1979 DETAIL SPECIFICATION JACKS, TELEPHONE GENERAL SPECIFICATION FOR This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers
2、jacks used in telephone (including telephone switchboard consoles), telegraph, and teletype circuits, and for connecting headsets, handsets, and microphones into communications circuits. 1.2 Classification. Jacks will be of the types specified (see 3.1). 2. APPLICABLE DOCUMENTS 2.1 General. The docu
3、ments listed in this section are specified in sections 3, 4, or 5 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this
4、 list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and h
5、andbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract (see 6.2). FEDERAL STANDARD FED-STD-H28/2 - Screw-Thread Standards for Federal Services Section 2 Unified Inch Screw Threads
6、 - UN and UNR Thread Forms. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-W-76 - Wire and Cable, Hookup, Electrical, Insulated. MIL-DTL-55330 - Connectors, Preparation for Delivery of. INCH-POUND Comments, suggestions, or questions on this document should be addressed to DLA Land and Maritime, Columbus,
7、ATTN: VAI, P.O. Box 3990 East Broad Street, Columbus, Ohio 43216-5000 or email to RFConnectordla.mil. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.dla.mil. Provided by IHSNot for ResaleNo repro
8、duction or networking permitted without license from IHS-,-,-MIL-DTL-641F 2 DEPARTMENT OF DEFENSE STANDARDS MIL-STD-1916 - DoD Preferred Methods for Acceptance of Product. MIL-STD-202 - Test Methods for Electronic and Electrical Component Parts. MIL-STD-464 - Electromagnetic Environmental Effects Re
9、quirements for Systems MIL-STD-1285 - Marking of Electrical and Electronic Parts. MIL-STD-1353 - Electrical Connectors and Hardware. (Copies of these documents are available online at http:/quicksearch.dla.mil/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philade
10、lphia, PA 19111-5094.) 2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract (see 6.2). ASME INTERNATIONAL ASME B107.100-2010- Soc
11、ket Wrenches, Handles, and Attachments. (Copies of these documents are available online at http:/www.asme.org or from the ASME International, Three Park Avenue, New York, NY 10016-5990.) ELECTRONIC COMPONENTS INDUSTRY ASSOCIATION (ECIA) EIA364 - Electrical Connector/Socket Test Procedures including
12、Environmental Classifications. (Copies of these documents are available online at http:/eciaonline.org or from the Electronic Components Industry Association (ECIA), 1111 Alderman Dr., Suite 400, Alpharetta, GA 30005-4175.) 2.4 Order of precedence. In the event of a conflict between the text of this
13、 document and the references cited herein (except for specification sheets), the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exception has been obtained. 3. REQUIREMENTS 3.1 Specification sheets. The individu
14、al item requirements shall be as specified herein and in accordance with the applicable specification sheets. In the event of conflict between requirements of this specification and the specification sheet, the latter shall govern. 3.2 Classification of requirements. The requirements for the jacks a
15、re classified herein as follows: Requirement Paragraph Qualification - - - - - - - - - - Materials- - - - - - - - - - - - - Design and construction- - Performance- - - - - - - - - - 3.3 3.4 3.5 3.6 3.3 Qualification. Jacks furnished under this specification shall be products which are qualified for
16、listing on the applicable qualified products list at the time set for opening of bids (see 4.4 and 6.4). 3.4 Materials. The materials shall be as specified herein. However, when a definite material is not specified, a material shall be used which enable the jacks to meet the performance requirements
17、 of this specification. Acceptance or approval of any constituent material shall not be construed as a guaranty of the acceptance of the finished product. 3.4.1 Fungus-inert. Materials used in the construction of these jacks shall be fungus-inert (see requirement 4 of MIL-STD-464). Provided by IHSNo
18、t for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-641F 3 3.4.2 Shells. Unless otherwise specified (see 3.1), shells shall be plastic and conforming to a polyarylether material, such as a polysulfone. 3.4.3 Metal parts. All metal parts shall be of corrosion-resi
19、stant material or shall be plated to resist corrosion, to permit compliance with the salt spray requirements of 3.6.11. 3.4.4 Springs. Contact springs shall be nickel-silver or copper alloy. Copper alloy springs shall be suitably plated to prevent corrosion of the basis metal. 3.4.5 Contact spring l
20、ifters. Hard rubber shall not be used for contact spring lifters. 3.5 Design and construction. 3.5.1 Jacks. Jacks shall be of the design and construction specified (see 3.1). 3.5.2 Cable clamp (see 3.1). A cable clamp for anchoring the electrical cable to the frame of the jack shall be supplied with
21、 the jack. If the cable clamp is not made as an integral part of the jack, the clamp shall be loosely assembled to or packaged with the jack. Twine serving is not acceptable for this service. 3.5.3 Conductor strain relief (see 3.1). Provisions for anchoring the stay cord to provide strain relief for
22、 the conductors of the electrical cable shall be included in the jack, all edges of the anchor in contact with the stay cord shall be rounded off. 3.5.4 Screw threads. Screw threads on removable or replaceable threaded parts shall be in accordance with ASME B107.100-2010. 3.5.5 Solder-lug terminals.
23、 Solder-lug terminals shall have circular or oval holes which will accommodate, after coating, two size 20 AWG, 7-strand wires for connections to electrical circuits. Stacked terminals shall be staggered. The exposed parts of the terminals shall be hot-tin-dipped or hot-solder-dipped, to facilitate
24、soldering. Care shall be taken that the terminal-lug holes are not closed by the solder. Where solder-dipping is employed, only noncorrosive fluxes shall be used. 3.6 Performance. 3.6.1 Contact resistance. When jacks are tested as specified in 4.6.2, the contact resistance shall not exceed 0.02 ohm,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILDTL641F2013JACKSTELEPHONEGENERALSPECIFICATIONFORPDF

链接地址:http://www.mydoc123.com/p-691055.html