《DLA MIL-DTL-13486 E-2006 CABLES SPECIAL PURPOSE ELECTRICAL LOW-TENSION HEAVY-DUTY SINGLE CONDUCTOR AND MULTIPLE CONDUCTOR SHIELDED AND UNSHIELDED GENERAL SPECIFICATION FOR《屏蔽和非屏蔽 单.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-DTL-13486 E-2006 CABLES SPECIAL PURPOSE ELECTRICAL LOW-TENSION HEAVY-DUTY SINGLE CONDUCTOR AND MULTIPLE CONDUCTOR SHIELDED AND UNSHIELDED GENERAL SPECIFICATION FOR《屏蔽和非屏蔽 单.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、INCH-POUNDProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHSMIL-DTL-13486E 8 May 2006 SUPERSEDING MIL-DTL-13486D 4 August 2000 DETAIL SPECIFICATION CABLES, SPECIAL PURPOSE, ELECTRICAL: LOW-TENSION, HEAVY-DUTY, SINGLE CONDUCTOR AND MULTIPLE CONDUCTOR, SHIELD
2、ED AND UNSHIELDED, GENERAL SPECIFICATION FOR This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers two types (shielded and unshielded) of insulated, heavy-duty, single and multiconductor, electrical cables f
3、or use in low-tension circuits (see 6.1). 1.2 Classification. Cable is of the following types and classes, as specified (see 6.1 and 6.2): Type I Unshielded Type II Shielded Class A Single Conductor Class B Multiconductor 1.2.1 Size and arrangement of conductors. Cable is furnished in the size or co
4、mbination of sizes and arrangement of conductors shown on the applicable specification sheet or drawing (see 6.2). 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this specification. This section does not include documents cited in ot
5、her sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements documents cited in sections 3, 4, or 5 of this specificat
6、ion, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards and handbooks. The following specifications, standards and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited i
7、n the solicitation or contract. Comments, suggestions, or questions on this document should be addressed to: Defense Logistics Agency, Defense Supply Center, Columbus (DSCC-VAI), P.O. Box 3990, Columbus, OH 43218-3990 or email to WireCabledscc.dla.mil. Since contract information can change, you may
8、want to verify the currency of this address information using the ASSIST Online database at http:/assist.daps.dla.mil. AMSC N/A FSC 6145 -,-,-MIL-DTL-13486E 2 FEDERAL STANDARD FED-STD-791 - Lubricants, Liquid Fuels, and Related Products; Methods of Testing COMMERCIAL ITEM DESCRIPTIONS A-A-59551 - Wi
9、re, Electrical, Copper (Uninsulated) A-A-52624 - Antifreeze, Multi Engine Type (Copies of these documents are available online at http:/assist.daps.dla.mil or http:/assist.daps.dla.mil/quicksearch/ or from the Standardization Document Order Desk, Building 4D, 700 Robbins Avenue, Philadelphia, PA 191
10、11-5094.) 2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. ASTM INTERNATIONAL ASTM G21 - Determining Resistance of Synthetic
11、 Polymeric Materials to Fungi (Copies of these documents are available online at http:/www.astm.org or from the ASTM International, P.O. Box C700, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959.) 2.4 Order of precedence. In event of a conflict between the text of this document and the refer
12、ences cited herein (except for related specification sheets), the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Specification sheets. The individual item require
13、ments shall be as specified herein and in accordance with the applicable specification sheet. In the event of any conflict between the requirements of this specification and the specification sheet, the latter shall govern. 3.2 Qualification. Cables furnished under this specification shall be produc
14、ts that are authorized by the qualifying activity for listing on the applicable qualified products list before contract award (see 4.4 and 6.3). 3.3 Materials. 3.3.1 Strands. The individual conductor strands (see 6.4) shall be made of soft or drawn and annealed, coated, type S, solid copper wire con
15、forming to the applicable requirements of A-A-59551. The strands shall be coated as specified therein using any applicable material specified. 3.3.2 Insulation. The insulation shall be such as to meet the construction and performance requirements specified herein. Provided by IHSNot for ResaleNo rep
16、roduction or networking permitted without license from IHS-,-,-MIL-DTL-13486E 3 3.3.3 Tape or braid. The tape or braid shall be free from any substance that may have a deteriorating effect on the insulation or on the sheath (see 6.4). Further, the tape or braid shall not be adversely affected by the
17、 compounding ingredients of the insulation or sheath. 3.3.4 Sheath. The sheath shall be made of material that meets the performance requirements in 3.5.2 through 3.5.12. A polychloroprene-based material is preferred. 3.3.5 Shielding (type II only). The individual strands for the shielding (see 6.4)
18、shall be made of the same material as specified in 3.3.1 for the conductor strands. The American Wire Gage (AWG) size of the individual strands shall be 34. 3.3.6 Separator. The separator shall be made of a fungus resistant material that shall be free of any substance that would have a deteriorating
19、 effect on the insulation or conductor. Further, the separator itself shall not be adversely affected by compounding ingredients used in the cable construction or process. 3.3.7 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or environmentally preferable materials
20、 should be used to the maximum extent possible, provided that the material meets or exceeds operational and maintenance requirements, and promotes economically advantageous life cycle costs. 3.4 Construction. Cable construction shall be in accordance with the applicable specification sheet for the P
21、art or Identifying Number (PIN) specified by the acquisition activity. The length of the cable shall be as specified in the specification sheet or as specified by the acquisition activity (see 6.2, 6.5, and 6.6). 3.4.1 Conductors. Conductors shall consist of individual strands that shall be free fro
22、m abrasion, kinks, and flats. The conductors shall be continuous throughout their length except joints in individual strands shall be in accordance with 3.4.1.3. The conductor shall be intact and in clean condition for soldering when the separator is stripped from it. 3.4.1.1 Cross section. The cros
23、s section of any conductor shall conform to the applicable requirements specified in table I. 3.4.1.2 Stranding. Stranding of the conductor shall be left or right-hand lay and, at the option of the contractor, may be bunched, concentric, or rope lay. When an uninsulated portion is cut, the stranding
24、 shall not tend to unlay and the completed conductor shall not tend to spread out. 3.4.1.3 Joints. 3.4.1.3.1 Sizes 0000 to 16. When the conductor is size 0000 to 16, joints shall be made by butt brazing or twisting strands together. Individual joints shall occur no closer together than one foot. In
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILDTL13486E2006CABLESSPECIALPURPOSEELECTRICALLOWTENSIONHEAVYDUTYSINGLECONDUCTORANDMULTIPLECONDUCTORSHIELDEDANDUNSHIELDEDGENERALSPECIFICATIONFOR

链接地址:http://www.mydoc123.com/p-689918.html