DIN EN ISO 8612-2010 Ophthalmic instruments - Tonometers (ISO 8612 2009) German version EN ISO 8612 2009《眼科仪器 眼压计(ISO 8612-2009) EN ISO 8612-2009》.pdf
《DIN EN ISO 8612-2010 Ophthalmic instruments - Tonometers (ISO 8612 2009) German version EN ISO 8612 2009《眼科仪器 眼压计(ISO 8612-2009) EN ISO 8612-2009》.pdf》由会员分享,可在线阅读,更多相关《DIN EN ISO 8612-2010 Ophthalmic instruments - Tonometers (ISO 8612 2009) German version EN ISO 8612 2009《眼科仪器 眼压计(ISO 8612-2009) EN ISO 8612-2009》.pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、February 2010 Translation by DIN-Sprachendienst.English price group 11No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).I
2、CS 11.040.70!$Nl“1574373www.din.deDDIN EN ISO 8612Ophthalmic instruments Tonometers (ISO 8612:2009)English translation of DIN EN ISO 8612:2010-02Ophthalmische Instrumente Augentonometer (ISO 8612:2009)Englische bersetzung von DIN EN ISO 8612:2010-02Instruments ophtalmiques Tonomtres (ISO 8612:2009)T
3、raduction anglaise de DIN EN ISO 8612:2010-02SupersedesDIN EN ISO 8612:2001-08www.beuth.deIn case of doubt, the German-language original shall be considered authoritative.Document comprises 19 pages03.10 DIN EN ISO 8612:2010-02 2 A comma is used as the decimal marker. National foreword This standard
4、 has been prepared by Technical Committee ISO/TC 172 “Optics and photonics”, Subcommittee SC 7 “Ophthalmic optics and instruments” (Secretariat: DIN, Germany) in collaboration with Technical Committee CEN/TC 170 “Ophthalmic optics” (Secretariat: DIN, Germany). The responsible German body involved in
5、 its preparation was the Normenausschuss Feinmechanik und Optik (Optics and Precision Mechanics Standards Committee). The DIN Standards corresponding to the International Standards referred to in clause 2 of this document are as follows: ISO 15004-1 DIN EN ISO 15004-1 IEC 60601-1 DIN EN 60601-1 Amen
6、dments This standard differs from DIN EN ISO 8612:2001-08 as follows: a) It has been specified that tonometers meeting the requirements of Annex A for reference tonometers need not undergo design compliance testing according to Annex B. b) Information to be provided by the manufacturer for design co
7、mpliance testing has been reduced. c) Reference tonometer (Annex A): Requirements for the flatness of the tonometer head and the corresponding verification procedures have been specified. d) Design compliance testing (Annex B): For the selection of the subjects, central corneal thicknesses 0,600 mm
8、have been specified as exclusion criteria. e) Design compliance testing (Annex B): The minimum number of measurements has been changed from 150 eyes to 120 measurement pairs and details relating to repeated measurements have been specified. f) The text of ISO 8612:2009 has been adopted. Previous edi
9、tions DIN EN ISO 8612: 2001-08 National Annex NA (informative) Bibliography DIN EN ISO 15004-1, Ophthalmic instruments Fundamental requirements and test methods Part 1: General requirements applicable to all ophthalmic instruments DIN EN 60601-1, Medical electrical equipment Part 1: General requirem
10、ents for basic safety and essential performance EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN ISO 8612 October 2009 ICS 11.040.70 Supersedes EN ISO 8612:2001English Version Ophthalmic instruments - Tonometers (ISO 8612:2009) Instruments ophtalmiques - Tonomtres (ISO 8612:2009) Ophthalmische I
11、nstrumente - Augentonometer (ISO 8612:2009) This European Standard was approved by CEN on 10 September 2009. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any altera
12、tion. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by trans
13、lation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, German
14、y, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG M
15、anagement Centre: Avenue Marnix 17, B-1000 Brussels 2009 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN ISO 8612:2009: EContents 2 DIN EN ISO 8612:2010-02 EN ISO 8612:2009 (E) Page Foreword .3 1 Scope4 2 Normative references4 3 Te
16、rms and definitions .4 4 Requirements.5 4.1 General .5 4.2 Design compliance testing (certification).5 4.3 Verification (instrument compliance)5 4.4 Construction and function6 5 Test methods .6 6 Accompanying documents 6 7 Additional information 6 8 Marking.7 Annex A (normative) Reference tonometer
17、and method for determining reference IOP8 Annex B (normative) Design compliance testing15 Foreword 3 is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by April 2010, and conflicting nat
18、ional standards shall be withdrawn at the latest by April 2010. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersed
19、es EN ISO 8612:2001. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Icel
20、and, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Endorsement notice The text of ISO 8612:2009 has been approved by CEN as a EN ISO 8612:2009 without any modification. This
21、 document (EN ISO 8612:2009) has been prepared by Technical Committee ISO/TC 172 “Optics and photonics” in collaboration with Technical Committee CEN/TC 170 “Ophthalmic optics” the secretariat of which DIN EN ISO 8612:2010-02 EN ISO 8612:2009 (E) 1 Scope This International Standard, together with IS
22、O 15004-1, specifies minimum requirements and the design compliance procedure for tonometers intended for routine clinical use in the estimation of intraocular pressure (IOP). This International Standard takes precedence over ISO 15004-1, if differences exist. NOTE The true intraocular pressure is s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DINENISO86122010OPHTHALMICINSTRUMENTSTONOMETERSISO86122009GERMANVERSIONENISO86122009 眼科 仪器 眼压 ISO86122009ENISO86122009PDF

链接地址:http://www.mydoc123.com/p-681949.html