BS EN 14902-2005 Ambient air quality - Standard method for the measurement of Pb Cd AS and Ni in the PM 10 fraction of suspended particulate matter《环境空气质量 测量悬浮颗粒物质PM 10成分中Pb、Cd、As和.pdf
《BS EN 14902-2005 Ambient air quality - Standard method for the measurement of Pb Cd AS and Ni in the PM 10 fraction of suspended particulate matter《环境空气质量 测量悬浮颗粒物质PM 10成分中Pb、Cd、As和.pdf》由会员分享,可在线阅读,更多相关《BS EN 14902-2005 Ambient air quality - Standard method for the measurement of Pb Cd AS and Ni in the PM 10 fraction of suspended particulate matter《环境空气质量 测量悬浮颗粒物质PM 10成分中Pb、Cd、As和.pdf(58页珍藏版)》请在麦多课文档分享上搜索。
1、 g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58Cd, As and Ni in the PM10 fraction of suspended particulate matterThe European Standard EN 14902:20
2、05 has the status of a British StandardICS 13.040.20Ambient air quality Standard method for the measurement of Pb, BRITISH STANDARDBS EN 14902:2005Incorporating corrigendum no. 1BS EN 14902:2005This British Standard was published under the authority of the Standards Policy and Strategy Committee on
3、27 September 2005 BSI 2007ISBN 0 580 46678 7Compliance with a British Standard cannot confer immunity from legal obligations.Amendments issued since publicationAmd. No. Date Comments17049 Corrigendum No. 130 April 2007 Equation 5 replacedNational forewordThis British Standard was published by BSI. I
4、t is the UK implementation of EN 14902:2005, incorporating corrigendum October 2006.The UK participation in its preparation was entrusted by Technical Committee EH/2, Air quality, to Subcommittee EH/2/3, Ambient atmospheres.A list of organizations represented on this subcommittee can be obtained on
5、request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 14902August 2005ICS 13.040.20 Incorporating corrigendum October 2006English versionAmb
6、ient air quality - Standard method for the measurement ofPb, Cd, As and Ni in the PM10 fraction of suspended particulatematterQualit de lair ambiant - Mthode normalise pour lamesure de Pb, Cd, As et Ni dans la fraction MP10 de lamatire particulaire en suspensionAuenluftbeschaffenheit - Standardisier
7、tes Verfahren zurBestimmung von Pb/Cd/As/Ni als Bestandteil der PM10Fraktion des SchwebstaubesThis European Standard was approved by CEN on 27 June 2005.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the statu
8、s of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A vers
9、ion in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia,
10、 Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR
11、 NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2005 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 14902:2005: EEN 14902:2005 (E) 2 Contents Page Foreword .3 1 Scope 4 2 Normative references.5 3 Terms, definitions an
12、d abbreviations .5 4 Principle8 5 Requirements .9 6 Reagents and gases.10 7 Apparatus .11 8 Sampling.12 9 Analysis 14 10 Quality control22 11 Calculation of results.23 12 Estimation of the measurement uncertainty of the method26 13 Performance characteristics determined in field tests .27 14 Reporti
13、ng of results .32 Annex A (informative) Examples of closed vessel microwave digestion procedures 33 Annex B (informative) Typical laboratory filter blank values as determined in the field validation tests35 Annex C (informative) Analytical interferences36 Annex D (informative) Approach to uncertaint
14、y estimation used in the field validation tests .40 Annex E (normative) List of minimum QA / QC procedures46 Annex F (informative) Procedure for the determination of the uncertainty of the method for an individual laboratory 48 Annex ZA (informative) Relationship with EU Directives 53 Bibliography .
15、54 EN 14902:2005 (E) 3 Foreword This European Standard (EN 14902:2005) has been prepared by Technical Committee CEN/TC 264 “Air quality”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by
16、 endorsement, at the latest by February 2006, and conflicting national standards shall be withdrawn at the latest by February 2006. This European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association (see Annex ZA). According to th
17、e CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxemb
18、ourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EN 14902:2005 (E) 4 1 Scope This European Standard specifies a method for the determination of particulate lead (Pb), cadmium (Cd), arsenic (As) and nickel (Ni) in ambient air that
19、can be used in the framework of the European Council Directive on Ambient Air Quality Assessment and Management 1 and the 1st2 and 4th3 Daughter Directives. Performance requirements with which the method has to comply are specified in this European Standard. The performance characteristics of the me
20、thod were determined in comparative field validation tests carried out at four European locations (see 4). This European Standard specifies a method for sampling of Pb, Cd, As and Ni as part of the PM10 aerosol, microwave digestion of the samples and analysis by graphite furnace atomic absorption sp
21、ectrometry or by inductively coupled plasma (quadrupole) mass spectrometry. This European Standard is applicable for the measurement of Pb, Cd, As and Ni as part of the PM10 aerosol fraction in the concentration ranges listed in Table 1. Table 1 Working ranges of the method in ng/m From To Pb 1 4 00
22、0 Cd 0,1 50 As 0,5 350 Ni 2 100 The actual lower limits of the working ranges depend upon the variability of the laboratory filter blank (5.3.1). The lower limits of the working ranges given in Table 1 are expected values based upon performance achieved in the field validation tests. Similarly the u
23、pper limits of the working ranges have been set arbitrarily based upon the maximum daily values measured during the field validation tests. The method can be applied to higher concentrations provided the PM10 collection characteristics of the sampler are not compromised. EN 14902:2005 (E) 5 2 Normat
24、ive references The following referenced documents are indispensable for the application of this European Standard. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 12341:1998, Air qualit
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN149022005AMBIENTAIRQUALITYSTANDARDMETHODFORTHEMEASUREMENTOFPBCDASANDNIINTHEPM10FRACTIONOFSUSPENDEDPARTICULATEMATTER

链接地址:http://www.mydoc123.com/p-572793.html