BS 9751 N0001-1980 Detail specification for fixed insulated (unshielded) radio frequency inductors - Wire wound on ferrite iron dust or phenolic cylindrical former - Full assessmen.pdf
《BS 9751 N0001-1980 Detail specification for fixed insulated (unshielded) radio frequency inductors - Wire wound on ferrite iron dust or phenolic cylindrical former - Full assessmen.pdf》由会员分享,可在线阅读,更多相关《BS 9751 N0001-1980 Detail specification for fixed insulated (unshielded) radio frequency inductors - Wire wound on ferrite iron dust or phenolic cylindrical former - Full assessmen.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD CONFIRMED APRIL1986 BS9751 N0001:1980 Detail specification for fixed insulated (unshielded) radio frequency inductors Wire wound on ferrite, iron dust or phenolic cylindrical former Full assessment level UDC 621.318.43.092.5BS9751N0001:1980 BSI04-2000 Committee reference ECL/18 ISBN
2、 0 580 11215 2 A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This docu
3、ment comprises a front cover, an inside front cover, pagesi andii, pages1 to13 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publication
4、Amd. No. Date CommentsBS9751N0001:1980 BSI 04-2000 i Contents Page 1 Ratings and characteristics 2 2 Marking of the part and package 2 3 Related documents 2 4 Ordering information 3 5 Certified test records 3 6 Delayed delivery 3 7 Additional information (not for inspection purposes) 3 8 Inspection
5、requirements 3 Figure 1 Derating curve 2 Table 1 Dimensions and ratings 1 Table 2 Electrical characteristics 11ii blankBS9751N0001:1980 BSI 04-2000 1 Table 1 Dimensions and ratings The range of values available in each pattern is given in PD9002. ELECTRONIC COMPONENTS OF ASSESSED QUALITY DETAIL SPEC
6、IFICATION IN ACCORDANCE WITH BS9751:1979 MANUFACTURERS TYPE NUMBER SeePD9002 Outline and dimensions. Third angle projection For ordering information seeclause4 INDUCTORS RADIO FREQUENCY STYLE INSULATED (UNSHIELDED) TYPICAL CONSTRUCTION: WIRE WOUND ON FERRITE, IRON DUST OR PHENOLIC CYLINDRICAL FORMER
7、 For values of dimensions seeTable 1 All dimensions inmm Marking information, seeclause2 FULL ASSESSMENT Pattern Rated dissipation (W at70 C) Isolation voltage V d.c. or a.c. peak Dimensions L max. D max. l min. d min. d nom. d max. A B C D E F 0.16 0.20 0.20 0.20 0.25 0.33 700 700 700 700 700 700 7
8、 9.9 10 10 12 25.5 2.7 4.2 3.9 4.5 5.6 8.0 25 25 25 25 25 25 0.45 0.55 0.55 0.55 0.55 0.65 0.50 0.65 0.60 0.60 0.65 0.70 0.55 0.70 0.66 0.66 0.70 0.77 Refer to Qualified Products List PD9002 for details of manufacturers approved to this specificationBS9751N0001:1980 2 BSI 04-2000 1 Ratings and chara
9、cteristics 1.1 Derating. The inductors covered by this specification shall be derated in accordance with Figure 1. 2 Marking of the part and package The marking of the part and package shall be in accordance with the requirements of1.1.6 of BS9750. 3 Related documents BS2488, Schedule of preferred n
10、umbers for the resistance of resistors and the capacitance of capacitors for telecommunication equipment. BS4849, 1,1,2- trichlorotrifluoroethane (R113). BS6001, Sampling procedures and tables for inspection by attributes. BS9000, General requirements for electronic components of assessed quality. B
11、S9750, Specification for fixed r.f. inductors of assessed quality: generic data and methods of test. PD9002, BS9000 Component selection guide. Inductance range: The preferred values are those of the E12 series of BS2488:1966 (IEC63). Where the use of intermediate values is essential they should be c
12、hosen from the E24 series of that document Standard selection tolerance: 10% Environmental classification: 55/100/21 Bump severity: 390m/s 2 ;4000 bumps total Vibration severity: 10Hz to500Hz: amplitude0.75mm or acceleration98m/s 2(whichever is less severe); of3h duration in each of2 planes one of w
13、hich shall be parallel to the axis of winding Low air pressure: 8.5kPa(85mbar) Limits of change after1000h endurance test: inductance 5% Q factor ) ) self resonant frequency ) Conforming to Table2A to Table2F as applicable ) d.c. resistance ) Temperature coefficient of inductance: 0 125 10 6 / C ove
14、r the range20 C to70 C Figure 1 Derating curveBS9751N0001:1980 BSI 04-2000 3 4 Ordering information Orders for inductors covered by this specification shall contain the following information (in accordance with1.1.15 of BS9750): a) value of rated inductance; b) selection tolerance of rated inductanc
15、e; c) number of this detail specification, i.e.BS9751 N0001; d) pattern. 5 Certified test records Certified test records shall be prepared in accordance with1.1.11 of BS9750 and shall be presented in the format given in Appendix C of that document. 6 Delayed delivery The provisions of1.1.9 of BS9750
16、 shall apply. 7 Additional information (not for inspection purposes) Not applicable. 8 Inspection requirements 8.1 When drying is called for, procedure1 of1.2.5.1 of BS9750 shall be used. 8.2 The uncertainty associated with the inductance measuring equipment used in the tests referred to in this spe
17、cification shall meet the requirements of1.2.5.2 of BS9750. 8.3 All test equipment uncertainty is additive to each specified requirement. 8.4 There shall be a satisfactory balance between high and low inductance values in the sample taken (seeAppendix B of BS9750). 8.5 Samples submitted to tests tha
18、t are marked “D” shall not be accepted for release under BS9000 (see2.6.5 of BS9000-1). 8.6 Where a subgroup contains more than one test, the tests shall be carried out in the order given in the test schedule. Inspection D or ND (seenote2) BS9750:1978 reference and condition of test IL AQL Performan
19、ce requirements (BS9750 reference unless otherwise specified) (seenote1) Group A To be conducted on a sampling basis lot by lot. Subgroup A2 not applicable. A0 tests carried out prior to formation of inspection lots Subgroup A0 Inductance Q factor ND 1.2.5.2.2 1.2.5.3; test fixture: TF-A for pattern
20、s A-E TF-B for pattern F 100% In accordance with Table 2 of this detail specification Subgroup A1 Visual examination Inductance Q factor ND 1.2.3 1.2.5.2.2 1.2.5.3; test fixture: TF-A for patterns A-E TF-B for pattern F S4 1.0% 1.2.3 In accordance with Table 2 of this detail specificationBS9751N0001
21、:1980 4 BSI 04-2000 Inspection D or ND (seenote2) BS9750:1978 reference and condition of test IL AQL Performance requirements (BS9750 reference unless otherwise specified) (seenote1) Subgroup A3 Self resonant frequency D.C. resistance ND 1.2.5.4.1 1.2.5.5, at 20 C S4 1.0% In accordance with Table 2
22、of this detail specification In accordance with Table 2 of this detail specification Subgroup A4 Voltage proof ND 1.2.5.7, mounted as in1.2.5.6.1 S4 2.5% 1.2.5.7 Subgroup A5 CTR information 1.1.11 Attributes information subgroups A1, A3 and A4 Group B To be conducted on a sampling basis, lot by lot.
23、 Subgroups B3, B4, B5, B6 and B7 not applicable Subgroup B1 Dimensioning and gauging ND 1.2.4; thickness of test plate to be1.5 0.05mm S4 1.0% In accordance with Table 1 of this detail specification Subgroup B2 Robustness of terminations Final measurements: Visual examination Inductance Q factor Sol
24、dering (solderability) Climatic sequence: Dry heat Cold Low air pressure D Seenote3 1.2.7.1; tests: Ua tensile Ub bending Uc torsion 1.2.7.1 (e) 1.2.5.2.2 1.2.5.3 1.2.7.2; temperature for(a) to be230 10 C 1.2.7.6; procedure3 of test Z/ABDM 100 C 55 C 8.5kPa(85 mbar) S3 2.5% 1.2.7.1 (e) %L u 2% In ac
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS9751N00011980DETAILSPECIFICATIONFORFIXEDINSULATEDUNSHIELDEDRADIOFREQUENCYINDUCTORSWIREWOUNDONFERRITEIRONDUSTORPHENOLICCYLINDRICALFORMERFULLASSESSMENPDF

链接地址:http://www.mydoc123.com/p-547668.html