BS 8458-2015 Fixed fire protection systems Residential and domestic watermist systems Code of practice for design and installation《固定消防系统 住宅用和家用水雾系统 设计和安装操作规范》.pdf
《BS 8458-2015 Fixed fire protection systems Residential and domestic watermist systems Code of practice for design and installation《固定消防系统 住宅用和家用水雾系统 设计和安装操作规范》.pdf》由会员分享,可在线阅读,更多相关《BS 8458-2015 Fixed fire protection systems Residential and domestic watermist systems Code of practice for design and installation《固定消防系统 住宅用和家用水雾系统 设计和安装操作规范》.pdf(62页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationBS 8458:2015Fixed fire protectionsystems Residential anddomestic watermistsystems Code of practicefor design and installationPublishing and copyright informationThe BSI copyright notice displayed in this document indicates when the documentwas last issued. The British Standa
2、rds Institution 2015Published by BSI Standards Limited 2015ISBN 978 0 580 85527 6ICS 13.220.01; 13.220.20The following BSI references relate to the work on this document:Committee reference FSH/18/5Draft for comment 14/30295812 DCPublication historyFirst published as DD 8458-1, October 2010First pub
3、lished as BS 8458, November 2015Amendments issued since publicationDate Text affectedBS 8458:2015 BRITISH STANDARDContentsForeword iiiIntroduction 11 Scope 22 Normative references 23 Terms and definitions 34 Preliminary work and consultation 74.1 Initial considerations 74.2 Consultation 74.3 Categor
4、y of system 74.4 Cylinder-based systems 84.5 Use of watermist systems as a compensatory feature 84.6 Special circumstances 95 System actuation 96 Design 106.1 Fire tests 106.2 Limits of application 116.3 System design 116.4 Extent of watermist system protection 126.5 Hydraulic calculations 126.6 Dis
5、charge performance 136.7 Discharge duration 136.8 Water supplies 136.9 Backflow prevention 186.10 Watermist nozzle coverage and location 186.11 Components 196.12 Electrical design and installation 246.13 Additives 247 Installation, commissioning and documentation 257.1 Installation 257.2 Commissioni
6、ng 267.3 Documentation 277.4 System data label 288 Maintenance 288.1 Inspecting and testing after commissioning and whilst in service 288.2 Reinstatement of the system 298.3 Log book 29AnnexesAnnex A (informative) Elements of a typical watermist fire suppressionsystem 30Annex B (informative) Watermi
7、st performance, reliability and resilience forsystems installed in the homes of vulnerable people 34Annex C (normative) Room fire tests for watermist systems with automaticnozzles 35Annex D (normative) Hydraulic calculations 47Annex E (informative) Example of system data label 52Bibliography 53BRITI
8、SH STANDARD BS 8458:2015 The British Standards Institution 2015 iList of figuresFigure 1 Stored water supply 15Figure 2 Mounting of nozzles within sloping ceilings 19Figure A.1 Fire pump and tank system 31Figure A.2 Fire pump and town mains system 32Figure A.3 Cylinder-based system 33Figure C.1 Corn
9、er test layout showing a two-nozzle arrangement 38Figure C.2 Between two nozzles test layout showing a two-nozzlearrangement 39Figure C.3 Beneath a nozzle test layout showing a two-nozzlearrangement 40Figure C.4 Corner fire test ignition and fuel package 41Figure C.5 Beneath a nozzle and between two
10、 nozzles fire test ignition andfuel package 42Figure C.6 Ventilation test layout showing a two-nozzle arrangement 43Figure C.7 Open room test layout showing a two-nozzle arrangement 44Figure D.1 Example of a square law graduation graph 51Figure D.2 Blank template of a square law graduation graph 51F
11、igure E.1 Example of system data label 52List of tablesTable 1 Category of system 8Table 2 Fire test maximum temperatures 10Table 3 Limits of application based on fire tests 11Table D.1 C values for various type of pipes 47Table D.2a K values for carbon steel tube conforming to BS EN 10255,Medium se
12、ries 48Table D.2b K values for CPVC conforming to ASTM F442 48Table D.2c K values for copper tube conforming to BS EN 1057:2006+A1,half-hard, R250 designation 48Table D.3a Typical equivalent lengths for steel fittings and valves 49Table D.3b Typical equivalent lengths for CPVC fittings and valves 49
13、Table D.3c Typical equivalent lengths for copper fittings and valves 50Summary of pagesThis document comprises a front cover, an inside front cover, pages i to iv,pages 1 to 54, an inside back cover and a back cover.BRITISH STANDARDBS 8458:2015ii The British Standards Institution 2015ForewordPublish
14、ing informationThis British Standard is published by BSI Standards Limited, under licence fromThe British Standards Institution, and came into effect on 30 November 2015.It was prepared by Subcommittee FSH/18/5, Watermist systems, under theauthority of Technical Committee FSH/18, Fixed fire fighting
15、 systems. A list oforganizations represented on these committees can be obtained on request totheir secretary.SupersessionThis British Standard supersedes DD 8458-1:2010, which is withdrawn.Relationship with other publicationsAttention is drawn to the requirements of BS EN 806, with particular regar
16、d tobackflow prevention, and to BS 1710 for guidance on identification and markingof pipework.Guidance on the application of automatic fire suppression systems is given inBS 9991, BS 9999, the Building Regulations 2010, Approved Document B for usein England 1, 2, Wales 3, 4 and its equivalents in Sc
17、otland 5 and NorthernIreland 6.Information about this documentWatermist fire suppression systems for residential and domestic applications aredesigned to provide an additional degree of protection of life and property,above that to be achieved by the installation of smoke and/or fire detectors andsy
18、stems.This British Standard presumes that the watermist fire suppression system willform part of an integrated fire safety system as part of the building design.This document converts DD 8458-1 into a full British Standard. It is a full revisionof the Draft for Development, and incorporates the foll
19、owing principal changes: clarification of the application of residential and domestic buildingcategorizations based on occupancy and risk; change to building height limit (from 20 m to 45 m); changes to fire test protocols: removal of one ventilation fire test; addition of two optional “open room” f
20、ire tests; changes to the limits of application dependent on fire tests successfullycompleted; increase in maximum nozzle spacing; expanded guidance on water supplies; additional measures for vulnerable people; additional recommendations for components.Product certification/inspection/testing. Users
21、 of this British Standard are advisedto consider the desirability of third-party certification/inspection/testing ofproduct conformity with this British Standard. Users seeking assistance inidentifying appropriate conformity assessment bodies or schemes may ask BSI toforward their enquiries to the r
22、elevant association.BRITISH STANDARD BS 8458:2015 The British Standards Institution 2015 iiiUse of this documentAs a code of practice, this British Standard takes the form of guidance andrecommendations. It should not be quoted as if it were a specification andparticular care should be taken to ensu
23、re that claims of compliance are notmisleading.Any user claiming compliance with this British Standard is expected to be able tojustify any course of action that deviates from its recommendations.This British Standard is intended for the use of designers, engineers, architects,surveyors, contractors
24、, installers and authorities having jurisdiction.It has been assumed in the preparation of this British Standard that theexecution of its provisions will be entrusted to appropriately qualified andexperienced people, for whose use it has been produced.Presentational conventionsThe provisions in this
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS84582015FIXEDFIREPROTECTIONSYSTEMSRESIDENTIALANDDOMESTICWATERMISTSYSTEMSCODEOFPRACTICEFORDESIGNANDINSTALLATION

链接地址:http://www.mydoc123.com/p-547382.html