BS 5041-5-1974 Fire hydrant systems equipment - Specification for boxes for foam inlets and dry riser inlets《消防栓系统设备 第5部分 泡沫入口及干式水嘴用箱规范》.pdf
《BS 5041-5-1974 Fire hydrant systems equipment - Specification for boxes for foam inlets and dry riser inlets《消防栓系统设备 第5部分 泡沫入口及干式水嘴用箱规范》.pdf》由会员分享,可在线阅读,更多相关《BS 5041-5-1974 Fire hydrant systems equipment - Specification for boxes for foam inlets and dry riser inlets《消防栓系统设备 第5部分 泡沫入口及干式水嘴用箱规范》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS5041-5: 1974 Incorporating Amendment No. 1 Fire hydrant systems equipment Part 5: Specification for Boxes for foam inlets and dry riser inlets UDC 69.027.84:621.643.41:614.844BS5041-5:1974 This British Standard, having beenapproved by the Fire Standards Committee and endorsed by t
2、he Chairman of theBuilding Divisional Council, was published under the authorityofthe Executive Boardon 26February 1974 BSI04-1999 First published as BS3980, March1966 First published as BS5041-5, February1974 The following BSI references relate to the work on this standard: Committee references FSM
3、/6, FSB/6/4 Draft for approval72/11307 ISBN 0 580 07561 3 Co-operating organizations The Fire Standards Committee, under whose supervision this BritishStandard was prepared, consists of representatives from the following Government departments and industrial organizations: Association of Municipal F
4、ire Offices Committee* Corporations* Fire Protection Association British Constructional Steelwork Greater London Council Association Greater London Council Chief Fire Officers Association* (LondonFireBrigade)* Concrete Society Home Office* Confederation of British Industry Industrial Fire Protection
5、 County Councils Association Association of Great Britain Department of Employment Institution of Civil Engineers (HMFactoryInspectorate) Institution of Fire Engineers* Department of the Environment* Institution of Municipal Engineers* Department of the Environment Ministry of Defence, Procurement (
6、Joint Fire Research Executive Organization and Fire Offices National Council of Building Committee)* Material Producers Department of Trade and Industry Royal Institute of British Architects (Marine Division)* Fire Extinguishing Trades Association The Government departments and scientific and indust
7、rial organizations marked with an asterisk in the above list, together with the following, were directly represented on the committee entrusted with the preparation of this British Standard: Aluminium Federation Ministry of Defence, Air Force British Ironfounders Association Department British Fire
8、Services Association Ministry of Defence, Army British Valve Manufacturers Department Association National Coal Board Copper Development Association National physical Laboratory Fire Hose Manufacturers (Ministry of Technology) Association Individual manufacturers Amendments issued since publication
9、Amd. No. Date of issue Comments 5505 March 1987 Indicated by a sideline in the marginBS5041-5:1974 BSI 04-1999 i Contents Page Co-operating organizations Inside front cover Foreword ii 1 Scope 1 2 Definitions 1 3 Manufacture 1 4 Materials and thickness 1 5 Dimensions 2 6 Manufacturers certificate 3
10、7 Marking 3 Figure 1 Typical drawing of box for two foam inlets 3 Figure 2 Typical drawing of box for dry risers (four inlets) 4 Table 1 Foam inlet boxes 2 Table 2 Boxes for dry risers 2 Publications referred to Inside back coverBS5041-5:1974 ii BSI 04-1999 Foreword This part of BS5041 was originall
11、y published as BS3980. However, while the metricated version of BS3980 was being prepared, it was decided that it would be logical to issue the revised edition as Part5 of BS5041 “Fire hydrant systems equipment”. Parts1 to4 of BS5041, the titles of which are given below, are at present in course of
12、preparation. Part 1: Landing valves for wet risers; Part 2: Landing valves for dry risers; Part 3: Inlet breechings for dry risers; Part 4: Boxes for landing valves for dry risers. This standard was originally proposed by the London Fire Brigade and has been prepared under the authority of the Fire
13、Standards Committee to provide detailed specifications for most of the special requirements for wet and dry risers and foam inlets described in BS5306-1. This part of BS5041 supersedes BS3980:1966 and is intended to fulfill the same purpose as that standard, that is, to define the standard sizes and
14、 details of boxes for foam inlets and dry riser inlets so as to enable architects and builders to specify a standard product in metric terms. The metric values are given in SIunits; for further information on these, reference should be made to BS3763 “The International System of units (SI)”. The wor
15、k sizes have been selected to conform to the first or second preferences in BS4011 “Recommendations for the co-ordination of dimensions in building. Basic sizes for building components and assemblies” and this has led to a slight reduction in the maximum permissible size of the box compared with tha
16、t specified in BS3980. The boxes can also be used for other purposes, e.g.for fuel oil inlets and inlets for drencher systems. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Complian
17、ce with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pagesi andii, pages1 to4, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had a
18、mendments incorporated. This will be indicated in the amendment table on theinside front cover.BS5041-5:1974 BSI 04-1999 1 1 Scope This British Standard specifies the requirements for boxes for foam inlets or dry risers manufactured in a choice of materials to suit a particular application. NOTEThe
19、titles of the British Standards referred to in this Standard are listed on the inside back cover. 2 Definitions For the purposes of this British Standard the following definitions apply: 2.1 Box a box containing the inlets of foam pipes or water mains, installed in, or within the boundaries of the s
20、ite of a building, preferably recessed in a wall with inlets normally at street level through which foam or water can be pumped to provide a supply at discharge points situated at various levels in the building 2.2 Dry riser a vertical pipe installed in a building for fire fighting purposes, fitted
21、with inlet connections at the base and with landing valves at specified points, which is normally dry but which is capable of being charged with water by pumping from fire service appliances 3 Manufacture 3.1 Box. The box shall be of robust construction with seamed edges to guard against the ingress
22、 of water. The bottom of the box shall be provided with a fall of not less than1 in12 and be suitably drained. The box shall be supplied with flanges not less than38mm wide on the external face (seeFigure 1 and Figure 2). The back of the box shall be provided with suitable holes to accommodate foam
23、inlets (of diameter65 mm or80mm) or dry risers (of diameter100 mm or150mm) (see BS4504). When there is more than one foam inlet in one box they shall be spaced at not less than175 mm centres. The box shall be supplied with suitable fixing lugs or screw holes in the back of the box to enable it to be
24、 built into position. 3.2 Door. The frame of the door shall be of rigid construction and designed to accommodate a spring lock. The door shall be side hung and shall open through approximately180 . The box shall have a striking plate to engage the lock when the door is closed. The spring lock shall
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS504151974FIREHYDRANTSYSTEMSEQUIPMENTSPECIFICATIONFORBOXESFORFOAMINLETSANDDRYRISERINLETS 消防栓 系统 设备 部分

链接地址:http://www.mydoc123.com/p-544815.html