BS 2G 124-2-1966 Specification for a c generators for aircraft - Variable frequency《航空器交流发电机规范 第2部分 变频》.pdf
《BS 2G 124-2-1966 Specification for a c generators for aircraft - Variable frequency《航空器交流发电机规范 第2部分 变频》.pdf》由会员分享,可在线阅读,更多相关《BS 2G 124-2-1966 Specification for a c generators for aircraft - Variable frequency《航空器交流发电机规范 第2部分 变频》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 2G124-2: 1966 Specification for A.C. generators for aircraft Part 2: Variable frequency UDC 629.13.066:621.313.3-8BS2G 124-2:1966 This British Standard, having been approved by the Aerospace Industry Standards Committee and endorsed by the Chairman ofthe Engineering Divisional Co
2、uncil, was published under theauthority of the General Council of the Institution on 30December 1966 BSI 04-2000 The following BSI references relate to the work on this standard: Committee reference ACE/42 Draft for comment 66/7395 ISBN 0 580 34139 9 Amendments issued since publication Amd. No. Date
3、 CommentsBS2G 124-2:1966 BSI 04-2000 i Contents Page Foreword ii 1 Scope 1 Section 1. General requirements 2 General construction 1 3 Cooling arrangements 1 4 Mounting and drive 1 5 Terminal arrangement 1 Section 2. Particular requirements 6 Voltage, frequency, phases and waveform 1 7 Rating and ove
4、rload requirements 1 8 Efficiency 1 9 Excitation 1 10 Overspeed 1 11 Vibration, acceleration, climatic proofing, radio interference and compass interference 2 12 Declaration of performance 2 13 Nameplate 2 Section 3. Tests 14 General 2 15 Weight moment of inertia and centre of gravity 2 16 Initial c
5、heck 2 17 Open-circuit characteristic and losses 2 18 Short-circuit characteristic and losses 3 19 Voltage balance 3 20 Temperature tests 3 21 Insulation tests 3 22 Overspeed tests 3 23 Wave form 3 24 Determination of reactances and time constants 4 25 Containment test 4 26 Endurance and overload te
6、st 4 27 Radio interference test 4 28 Altitude test 4 29 Vibartion test 5 30 Acceleration test 5 31 Climatic tests 5 32 Compass interference test 5 33 Resistance of windings 5 34 Overspeed test 5 35 Open-circuit characteristic 5 36 Phase sequence and voltage balance 5 37 Short-circuit characteristic
7、5 38 Heat test 6 39 Insulation tests 6 40 Sampling 6 41 Testing 6BS2G 124-2:1966 ii BSI 04-2000 Foreword This standard has been prepared as part of a programme of work to bring the aircraft series British Standards for rotating machines up to date in relation to present-day and probable future requi
8、rements, and to experience gained in working to earlier issues of the standards. The standard is published in two parts, Part 1 dealing with constant frequency generators, being a revision of BS G 124:1950, and Part 2 with variable frequency machines. Reference is made in the standard to the followi
9、ng: BS 2G100, General requirements for electrical equipment and indicating instruments for aircraft. BS G102, General requirements for rotating electrical machines for aircraft 1) . BS , Methods of test for determining synchronous machine quantities 1) . A British Standard does not purport to includ
10、e all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i
11、 and ii, pages1 to 6 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. 1) In course of preparation.BS2G 124-2:1966 BSI 04-2000 1 1 Scope This part of BS G 124 specif
12、ies the general design and test procedure for generators for aircraft variable frequency a.c. power supply. It is intended to be read in conjunction with BS 2G 100 and BSG102. 2) Section 1. General requirements 2 General construction Unless otherwise stated, the design and construction of the machin
13、e shall comply with the relevant requirements of BS 2G 100 and BS G 102. 2) The design aim should be to achieve 3 000 (aircraft) hours operation of the machine before requiring maintenance. 3 Cooling arrangements a) The manufacturer and purchaser shall agree upon the cooling arrangements to be provi
14、ded for the machine. b) Cooling connections shall comply with the requirements of BS G 102. 2) 4 Mounting and drive The mounting and drive of the machine shall comply with the requirements of BS G 102. 2) 5 Terminal arrangement The machine terminals shall comply with the requirements of BS 2G 100-1,
15、 and of BS G 102. 2) Section 2. Particular requirements 6 Voltage, frequency, phases and waveform a) The full load voltage of the machine shall be120/208 volts for a nominal 115/200 volt a.c. system and the rated line current shall relate to rated kVA at the rated system volts. b) The voltage and it
16、s waveform, frequency, number and sequence of phases of the machineshall comply with the requirements ofBS 2G 100-3. 3) 7 Rating and overload requirements a) Unless otherwise stated, the machine shall be capable of providing rated output continuously over the whole speed range. b) The manufacturer s
17、hall declare the cooling requirements in the form of rating charts in accordance with BS G 102. 2) c) With the frequency maintained at 400 Hz following rated load operation at steady temperature conditions at the speed giving an output frequency of 400 Hz the machine shall: i) Maintain rated voltage
18、 for two minutes at150 per cent rated current and minimum ratedpower factor. ii) Withstand 200 per cent rated current for five seconds at minimum rated power factor. When agreed between the manufacturer and purchaser, the output voltage of the machine may fall to not less than90 per cent of rated vo
19、ltage. iii) Produce a symmetrical three-phase short-circuit current of at least300 per cent rated current. 8 Efficiency The manufacturer shall declare the power required to drive the machine at rated voltage, current, power factor at maximum, and minimum speeds, and at a speed for 400Hz. 9 Excitatio
20、n The excitation system shall be independent of any external electrical supply, and shall be capable of initial build-up without reference to any other supply. Supplement excitation may be employed by agreement between the manufacturer and purchaser. 10 Overspeed Consideration should be given to the
21、 highest speed at which the generator could be driven, in the applications for which it is intended, if all overspeed protection devices fail. If this speed is more than125per cent of the maximum rated speed, the machine shall be designed either to withstand the highest speed, or to fail at a lower
22、speed and to contain all its parts within the machine frame after failure. The containment requirements and the necessary proving tests shall be agreed between the manufacturer and the user. 2) In course of preparation. 3) BS 2G100-3:1960 is being revised to include requirements for variable frequen
23、cy a.c. systems.BS2G 124-2:1966 2 BSI 04-2000 11 Vibration, acceleration, climatic proofing, radio interference and compass interference The machine shall comply with the requirements of BS 2G 100-2 in respect of: 12 Declaration of performance In addition to the declarations required by BS2G100, the
24、 following information shall be provided by the manufacturer in regard to the machine: a) Continuous rated output under declared conditions of altitude and cooling. b) Cooling requirements for conditions other than those declared in a). c) Power required to drive the machine under the conditions spe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS2G12421966SPECIFICATIONFORACGENERATORSFORAIRCRAFTVARIABLEFREQUENCY 航空器 交流 发电机 规范 部分 变频 PDF

链接地址:http://www.mydoc123.com/p-543394.html