BS 2G 124-1-1966 Specification for a c generators for aircraft - Constant frequency《航空器交流发电机规格 恒定频率》.pdf
《BS 2G 124-1-1966 Specification for a c generators for aircraft - Constant frequency《航空器交流发电机规格 恒定频率》.pdf》由会员分享,可在线阅读,更多相关《BS 2G 124-1-1966 Specification for a c generators for aircraft - Constant frequency《航空器交流发电机规格 恒定频率》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS2G124-1: 1966 Incorporating Amendment No.1 Specification for A.C. generators for aircraft Part 1: Constant frequency UDC 629.13.066:621.313.3-8BS2G 124-1:1966 This British Standard, having been approved by the AerospaceIndustry Standards Committee and endorsed bytheChairman of the
2、 Engineering Divisional Council, was published under the authorityof the General Councilofthe Institution on 16 June1966 BSI 01-2000 The following BSI references relate to the work on this standard: Committee reference ACE/42 Draft for comment D64/6732 ISBN 0 580 34123 2 Amendments issued since publ
3、ication Amd. No. Date of issue Comments 421 February 1970 Indicated by a sideline in the marginBS2G124-1:1966 BSI 01-2000 i Contents Page Foreword ii 1 Scope 1 Section 1. General requirements 2 General construction 1 3 Cooling arrangements 1 4 Mounting and drive 1 5 Terminal arrangement 1 Section 2.
4、 Particular requirements 6 Voltage, frequency, phases and waveform 1 7 Rating and overload requirements 1 8 Efficiency 1 9 Excitation 1 10 Overspeed 1 11 Vibration, acceleration, climatic proofing, radio interference and compass interference 2 12 Declaration of performance 2 13 Name plate 2 Section
5、3. Tests 14 General 2 15 Weight, moment of inertia and centre of gravity 2 16 Initial check 2 17 Open-circuit characteristic and losses 2 18 Short-circuit characteristic and losses 3 19 Voltage balance 3 20 Temperature tests 3 21 Insulation tests 3 22 Overspeed tests 3 23 Wave form 3 24 Determinatio
6、n of reactances and time constants 3 25 Containment test 4 26 Endurance and overload test 4 27 Radio interference test 4 28 Altitude test 4 29 Vibration test 4 30 Acceleration test 4 31 Climatic tests 5 32 Compass interference test 5 33 Resistance of windings 5 34 Overspeed test 5 35 Open-circuit ch
7、aracteristic 5 36 Phase sequence and voltage balance 5 37 Short-circuit characteristic 5 38 Heat test 5 39 Insulation tests 5 40 Sampling 5 41 Testing 6BS2G 124-1:1966 ii BSI 01-2000 Foreword This standard has been prepared as part of a programme of work to bring the aircraft series British Standard
8、s for rotating machines up to date in relation to present-day and probable future requirements, and to experience gained in working to earlier issues of the standards. It is intended to publish the standard in two parts: Part1 dealing with constant frequency generators, being a revision of BSG124:19
9、50, and Part2 with variable frequency machines. Reference is made in the standard to the following: BS2G100, General requirements for electrical equipment and indicating instruments for aircraft. BSG102, General requirements for rotating electrical machines for aircraft 1) . BS, Methods of test for
10、determining synchronous machine quantities 1) . A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obliga
11、tions. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages1 to6 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. 1)
12、 In course of preparation.BS2G124-1:1966 BSI 01-2000 1 1 Scope This part of BSG124 specifies the general design and test procedure for generators for aircraft three-phase constant frequency a.c. power supply. It is intended to be read in conjunction with BS2G100 and BSG102. Section 1. General requir
13、ements 2 General construction Unless otherwise stated, the design and construction of the machine shall comply with the relevant requirements of BS2G100 and BSG102. The design aim should be achieve3000 (aircraft) hours operation of the machine before requiring maintenance. 3 Cooling arrangements a)
14、The manufacturer and purchaser shall agree upon the cooling arrangements to be provided for the machine. b) Cooling connections shall comply with the requirements of BS2G102. 4 Mounting and drive The mounting and drive of the machine shall comply with the requirements of BSG102. 5 Terminal arrangeme
15、nt The machine terminals shall comply with the requirements of BS2G100-1, and of BSG102. Section 2. Particular requirements 6 Voltage, frequency, phases and waveform a) The full load voltage of the machine shall be120/208volts for a nominal115/200volt a.c. system and the rated line current shall rel
16、ate to rated kVA at the rated system volts. b) The voltage and its waveform, frequency, number and sequence of phases of the machine shall comply with the requirements of BS2G100-3. 7 Rating and overload requirements a) The manufacturer shall declare the continuous rated output of the machine under
17、declared conditions of altitude and cooling. b) The manufacturer shall declare the cooling requirements for other conditions in the form of rating charts in accordance with BSG102. c) Immediately after rated load operation at anambient temperature of20 5 C, and, for i) and ii) below, with the equiva
18、lent regulator load applied, the machine shall be capable of meeting each of the following conditions individually: i) maintain rated voltage at rated speed for two minutes at150 per cent rated load. ii) maintain rated voltage at minimum rated power factor for five seconds at200 per cent rated load.
19、 When agreed between the manufacturer and the purchaser, the output voltage of the machine may fall to not less than90 per cent of rated voltage. iii) produce at least300 per cent rated current under symmetrical three-phase short-circuit conditions for two seconds. 8 Efficiency The manufacturer shal
20、l declare the power required to drive the machine at rated voltage, current, power factor and nominal speed when at stabilized temperature conditions due to cooling at rated air flow appropriate to sea level conditions, and when being controlled by the appropriate voltage regulator. 9 Excitation The
21、 excitation system shall be independent of any external electrical supply, and shall be capable of initial build-up without reference to any other supply. Supplementary excitation may be employed by agreement between the manufacturer and the purchaser. 10 Overspeed Consideration should be given to t
22、he highest speed at which the generator could be driven, in the applications for which it is intended, if all overspeed protection devices fail. If this speed is more than125per cent of the rated speed, the machine shall be designed either to withstand the highest speed, or to fail at a lower speed
23、of not less than125per cent of the rated speed, and to contain all its parts within the machine frame after failure. The containment requirements and the necessary proving tests shall be agreed between the manufacturer and the user.BS2G 124-1:1966 2 BSI 01-2000 11 Vibration, acceleration, climatic p
24、roofing, radio interference and compass interference The machine shall comply with the requirements of BS2G100-2 in respect of: 12 Declaration of performance In addition to the declarations required by BS2G100, the following information shall be provided by the manufacturer in regard to the machine:
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS2G12411966SPECIFICATIONFORACGENERATORSFORAIRCRAFTCONSTANTFREQUENCY 航空器 交流 发电机 规格 恒定 频率 PDF

链接地址:http://www.mydoc123.com/p-543393.html