1、 ANSI/BHMA A156.19-2013 Revision of ANSI/BHMA A156.19-2007 AMERICAN NATIONAL STANDARD FOR POWER ASSIST AND LOW ENERGY POWER OPERATED DOORS SPONSOR BUILDERS HARDWARE MANUFACTURERS ASSOCIATION, INC. AMERICAN NATIONAL STANDARDS INSTITUTE Approved July 17, 2013 2 AMERICAN NATIONAL STANDARD An American N
2、ational Standard implies a consensus of those substantially concerned with its scope and provisions. An American National Standard is intended as a guide to aid the manufacturer, the consumer and the general public. The existence of an American National Standard does not in any respect preclude anyo
3、ne, whether he has approved the Standard or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the Standard. American National Standards are subject to periodic review and users are cautioned to obtain the latest editions. CAUTION NOTICE: Th
4、is American National Standard is permitted to be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken to reaffirm, revise, or withdraw this Standard no later than five years from the date of publication. Purchasers of American Nat
5、ional Standards receive current information on all Standards by calling or writing The American National Standards Institute. Published by BUILDERS HARDWARE MANUFACTURERS ASSOCIATION, INC. 355 Lexington Avenue New York, New York 10017 Copyright 2013 by the Builders Hardware Manufacturers Associatio
6、n, Inc. Not to be reproduced without specific authorization from BHMA Printed in the USA This Standard was developed by the Builders Hardware Manufacturers Association, Inc. It was approved by ANSI under the Canvass Method. BHMA was accredited on 21 March 1983 as a sponsor using the Canvass Method.
7、3 FOREWORD (This Foreword is not a part of ANSI/BHMA A156.19) The general classification of builders hardware includes a wide variety of items which are divided into several categories. To recognize this diversity, a sectional classification system has been established. Power Operated Doors is one s
8、uch section and this Standard is a result of the collective efforts of members of the Builders Hardware Manufacturers Association, Inc. who manufacture this product. The total Product Standards effort is, therefore, a collection of sections, each covering a specific category of items. Performance te
9、sts and, where necessary, dimensional requirements have been established to ensure a degree of safety. There are no restrictions on design except for those dimensional requirements imposed for reasons of safety. This Standard is not intended to obstruct but rather to encourage the development of imp
10、roved products, methods and materials. The BHMA recognizes that errors will be found, items will become obsolete, and new products, methods and materials will be developed. With this in mind, the Association plans to update, correct and revise these Standards on a regular basis. It shall also be the
11、 responsibility of manufacturers to request such appropriate revisions. 4 TABLE OF CONTENTS 1. GENERAL .5 2. DEFINITIONS .5 3. REQUIREMENTS FOR SWINGING POWER ASSIST DOORS .6 4. REQUIREMENTS FOR LOW ENERGY SWINGING POWER OPERATED DOORS 6 5. CYCLE TESTS 7 6. SIGNS 9 APPENDIX A (not a part of ANSI/BHM
12、A A156.19) 10 5 1. GENERAL 1.1 Requirements in this Standard apply only to swing door operators. The operator types are power assist, and low energy power operators, for pedestrian use, and some small vehicular use. It does not address doors, finish or hardware. The activation of all doors described
13、 in this standard requires a knowing act. Included are provisions intended to reduce the chance of user injury or entrapment. 1.2 Doors that require higher speeds, forces, shorter time delays, and activating sensing devices shall comply with ANSI/BHMA A156.10 for Power Operated Pedestrian Doors and
14、are not covered in A156.19. 1.3 This Standard does not attempt to assess any factors that exist with respect to custom design installations which are not required to meet the requirements of this Standard. 1.4 Unless otherwise specified, all references to time delay, opening speed and forces in this
15、 standard, refer to the operator in the power mode as opposed to the manual mode. 1.5 Required dimensions are expressed in US units first and the SI (metric) equivalents given in parentheses are approximate. All values which do not carry specific tolerances or are not marked maximum or minimum shall
16、 have the following tolerances: Linear dimensions shall be 1/16 in (1.6 mm). Pounds or pound force shall be 5%. Angular measurements shall be 4 degrees. Voltage measurements shall be 5 percent. Temperature measurements shall be 4 degrees F (2 degrees C). 1.6 Compliance with the requirements of this
17、standard shall be accomplished through factory settings or field adjustments as necessary. 1.7 Operators used on labeled fire door assemblies shall be listed or labeled by a nationally recognized independent testing laboratory, and be subject to a periodic in-plant follow-up service. Consult the aut
18、hority having jurisdiction for the appropriate fire test requirements. 2. DEFINITIONS 2.1 Knowing Act Consciously initiating the powered opening of a low-energy door using acceptable methods including: wall or jamb-mounted contact switches such as push plates; fixed non-contact switches; the action
19、of manual opening (pushing or pulling) a door; and controlled access devices such as keypads, card readers, and keyswitches. 2.2 Low Energy Power Operated Door A door with a power mechanism that opens the door upon receipt of a knowing act activating signal, does not generate more kinetic energy tha
20、n specified in this Standard, and is closed by a power mechanism or by other means. 2.3 Power Assist Door A door with a power mechanism that activates by pushing or pulling the door, reducing the opening resistance of a self-closing door to allow easier manual opening of the door. If the opening for
21、ce on the door is released, the door shall come to a stop and either immediately begin to close, or begin to close after a predetermined time. 2.4 Push-Pull Activation A door where the user pushes or pulls a door equipped with a Low Energy Power Operator to activate a mechanism, causing the door to
22、go through a complete cycle of automatic opening, hold open time delay, and closing. 2.5 Small Vehicular Carts used to transport people or objects. 6 3. REQUIREMENTS FOR POWER ASSIST DOORS 3.1 Activation Power assist doors shall operate only by pushing or pulling the door. An activating means is per
23、mitted to be used to put the door in the power assist mode. 3.2 Opening If the opening force on the door is released, the door shall come to a stop and either immediately begin to close or begin to close after a predetermined time. 3.3 Time Delay Not required. 3.4 Closing Doors shall close from 90 d
24、egrees to 10 degrees from closed, in 3 seconds or longer as required in Table I. Doors shall close from 10 degrees to fully closed in not less than 1.5 seconds. 3.5 Force and Kinetic Energy The force required to prevent a door from closing shall not exceed 15 lbf (67 N) measured 1 inch (25 mm) from
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BHMAA156192013POWERASSISTANDLOWENERGYPOWEROPERATEDDOORS 电力 协助 能耗 功率 PDF

链接地址:http://www.mydoc123.com/p-542479.html