ASTM F744M-2016 Standard Test Method for Measuring Dose Rate Threshold for Upset of Digital Integrated Circuits (Metric)《测量数字集成电路 (米制) 混乱用剂量率阀值的标准试验方法》.pdf
《ASTM F744M-2016 Standard Test Method for Measuring Dose Rate Threshold for Upset of Digital Integrated Circuits (Metric)《测量数字集成电路 (米制) 混乱用剂量率阀值的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F744M-2016 Standard Test Method for Measuring Dose Rate Threshold for Upset of Digital Integrated Circuits (Metric)《测量数字集成电路 (米制) 混乱用剂量率阀值的标准试验方法》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F744M 16Standard Test Method forMeasuring Dose Rate Threshold for Upset of DigitalIntegrated Circuits (Metric)1This standard is issued under the fixed designation F744M; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This test method cov
3、ers the measurement of the thresh-old level of radiation dose rate that causes upset in digitalintegrated circuits only under static operating conditions. Theradiation source is either a flash X-ray machine (FXR) or anelectron linear accelerator (LINAC).1.2 The precision of the measurement depends o
4、n thehomogeneity of the radiation field and on the precision of theradiation dosimetry and the recording instrumentation.1.3 The test may be destructive either for further tests or forpurposes other than this test if the integrated circuit beingtested absorbs a total radiation dose exceeding some pr
5、edeter-mined level. Because this level depends both on the kind ofintegrated circuit and on the application, a specific value mustbe agreed upon by the parties to the test (6.8).1.4 Setup, calibration, and test circuit evaluation proceduresare included in this test method.1.5 Procedures for lot qual
6、ification and sampling are notincluded in this test method.1.6 Because of the variability of the response of differentdevice types, the initial dose rate and device upset conditionsfor any specific test is not given in this test method but must beagreed upon by the parties to the test.1.7 The values
7、 stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.8 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safet
8、y and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E666 Practice for Calculating Absorbed Dose From Gammaor X RadiationE668 Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Ab
9、sorbedDose in Radiation-Hardness Testing of Electronic DevicesE1894 Guide for Selecting Dosimetry Systems for Applica-tion in Pulsed X-Ray SourcesF526 Test Method for Using Calorimeters for Total DoseMeasurements in Pulsed Linear Accelerator or FlashX-ray Machines3. Terminology3.1 Definitions:3.1.1
10、combinatorial logic circuitintegrated circuit whoseoutput is a unique function of the inputs; the output changes ifand only if the input changes (for example, AND- andOR-gates).3.1.2 dose rateenergy absorbed per unit time and per unitmass by a given material from the radiation to which it isexposed.
11、3.1.3 dose rate threshold for upsetminimum dose rate thatcauses either: (1) the instantaneous output voltage of anoperating digital integrated circuit to be greater than thespecified maximum LOW value (for a LOW output level) orless than the specified minimum HIGH value (for a HIGHoutput level), or
12、(2) a change of state of any stored data.3.1.4 sequential logic circuitintegrated circuit whose out-put or internal operating conditions are not unique functions ofthe inputs (for example, flip-flops, shift registers, and RAMs).4. Summary of Test Method4.1 The test device and suitable dosimeters are
13、 irradiated byeither an FXR or a linac. The test device is operating but under1This test method is under the jurisdiction of ASTM Committee F01 onElectronics and is the direct responsibility of Subcommittee F01.11 on Nuclear andSpace Radiation Effects.Current edition approved May 1, 2016. Published
14、May 2016. Originallyapproved in 1981. Last previous edition approved in 2010 as F744M 10. DOI:10.1520/F0744M-16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the
15、standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1static conditions. The output(s) of the test device and of thedosimeters are recorded.4.2 The dose rate is varied to determine the rate
16、 whichresults in upset of the test device.4.3 For the purposes of this test method, upset is consideredto be either of the following:4.3.1 An output voltage transient exceeding a predeter-mined value, or4.3.2 For devices having output logic levels which are notunique functions of the input logic lev
17、els, such as flip-flops, achange in the logic state of an output.4.3.3 For sequential logic circuits, a change of state of aninternal storage element or node.4.4 A number of factors are not defined in this test method,and must be agreed upon beforehand by the parties to the test:4.4.1 Total ionizing
18、 dose limit (see 1.3),4.4.2 Transient values defining an upset (see 4.3.1),4.4.3 Temperature at which the test is to be performed (see6.7),4.4.4 Details of the test circuit, including output loading,power supply levels, type of package, and other operatingconditions (see 7.4, 10.3, and 10.4),4.4.5 C
19、hoice of radiation pulse source (see 7.7),4.4.6 Radiation pulse width and rise time (see 7.7.2),4.4.7 Sampling (see 8.1),4.4.8 Need for total ionizing dose measurement (see 6.8,7.6, and 10.1),4.4.9 Desired precision of the upset threshold (see 10.8),and4.4.10 Initial dose rate (see 1.6 and 10.5).5.
20、Significance and Use5.1 Digital integrated circuits are specified to operate withtheir inputs and outputs in either a logical 1 or a logical 0 state.The occurrence of signals having voltage levels not meetingthe specifications of either of these levels (an upset condition)may cause the generation an
21、d propagation of erroneous data ina digital system.5.2 Knowledge of the radiation dose rate that causes upsetin digital integrated circuits is essential for the design,production, and maintenance of electronic systems that arerequired to operate in the presence of pulsed radiation envi-ronments.6. I
22、nterferences6.1 Air IonizationA spurious component of the signalmeasured during a test can result from conduction through airionized by the radiation pulse. The source of such spuriouscontributions can be checked by measuring the signal whileirradiating the test fixture in the absence of a test devi
23、ce. Airionization contributions to the observed signal are generallyproportional to the applied field, while those due to secondaryemission effects (6.2) are not. The effects of air ionizationexternal to the device may be minimized by coating exposedleads with a thick layer of paraffin, silicone rub
24、ber, or noncon-ductive enamel or by making the measurement in a vacuum.6.2 Secondary EmissionAnother spurious component ofthe measured signal can result from charge emission from, orcharge injection into, the test device and test circuit.3This maybe minimized by shielding the surrounding circuitry a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF744M2016STANDARDTESTMETHODFORMEASURINGDOSERATETHRESHOLDFORUPSETOFDIGITALINTEGRATEDCIRCUITSMETRIC

链接地址:http://www.mydoc123.com/p-537203.html