ASTM F1867-2006 Standard Practice for Installation of Folded Formed Poly (Vinyl Chloride) (PVC) Pipe Type A for Existing Sewer and Conduit Rehabilitation《现存排水道和管线修复用A型折叠 成型聚乙烯(乙烯基氯.pdf
《ASTM F1867-2006 Standard Practice for Installation of Folded Formed Poly (Vinyl Chloride) (PVC) Pipe Type A for Existing Sewer and Conduit Rehabilitation《现存排水道和管线修复用A型折叠 成型聚乙烯(乙烯基氯.pdf》由会员分享,可在线阅读,更多相关《ASTM F1867-2006 Standard Practice for Installation of Folded Formed Poly (Vinyl Chloride) (PVC) Pipe Type A for Existing Sewer and Conduit Rehabilitation《现存排水道和管线修复用A型折叠 成型聚乙烯(乙烯基氯.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 1867 06An American National StandardStandard Practice forInstallation of Folded/Formed Poly (Vinyl Chloride) (PVC)Pipe Type A for Existing Sewer and Conduit Rehabilitation1This standard is issued under the fixed designation F 1867; the number immediately following the designation indi
2、cates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the procedures for t
3、he rehabilitationof sewer lines and conduits 4 in. (102 mm) to 18 in. (457 mm)in diameter by the insertion of a folded/formed PVC pipe thatis heated, pressurized, and expanded to conform to the wall ofthe original conduit forming a new structural pipe-within-a-pipe. This rehabilitation process can b
4、e used in a variety ofgravity applications such as sanitary sewers, storm sewers, andprocess piping.1.2 This practice is to be used with the material specified inSection 6 of Specification F 1871.1.3 The values stated in inch-pound units are to be regardedas the standard. The SI units given in paren
5、theses are providedfor information only.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory
6、limitations prior to use.1.5 There is no similar or equivalent ISO Standard.2. Referenced Documents2.1 ASTM Standards:2D 638 Test Method for Tensile Properties of PlasticsD 648 Test Method for Deflection Temperature of PlasticsUnder Flexural Load in the Edgewise PositionD 790 Test Methods for Flexur
7、al Properties of Unreinforcedand Reinforced Plastics and Electrical Insulating MaterialsD 1600 Terminology for Abbreviated Terms Relating toPlasticsD 1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)Compounds and Chlorinated Poly(Vinyl Chloride)(CPVC) CompoundsD 2122 Test Method for Determinin
8、g Dimensions of Ther-moplastic Pipe and FittingsF 412 Terminology Relating to Plastic Piping SystemsF 1417 Test Method for Installation Acceptance of PlasticGravity Sewer Lines Using Low-Pressure AirF 1871 Specification for Folded/Formed Poly (Vinyl Chlo-ride) Pipe Type A for Existing Sewer and Cond
9、uit Reha-bilitation2.2 Uni-Bell Standard:UNI-B-5-89 Recommended Practice for the Installation ofPolyvinyl Chloride (PVC) Sewer Pipe33. Terminology3.1 DefinitionsDefinitions are in accordance with Termi-nology F 412, and abbreviations are in accordance with Ter-minology D 1600, unless otherwise indic
10、ated. The abbrevia-tion for poly(vinyl chloride) plastics is PVC.3.1.1 The term TYPE A is not an abbreviation but rather anarbitrary designation for PVC compounds with a minimumvalue for modulus in tension as listed in 6.1 and a maximumvalue as defined by cell limit 1 of Specification D 1784.3.2 Def
11、initions of Terms Specific to This Standard:3.2.1 dimples (dimpling), nWhere a side connectionmeets the existing conduit, there is no support for the PVC pipeduring forming, causing a point of thermoplastic pipe expan-sion slightly beyond the existing pipe wall. This formation ofan external departur
12、e from the formed pipe wall is termeddimpling.3.2.2 flattened pipe, na flattened pipe has been manufac-tured and calibrated round, then subsequently cooled anddeformed into a flattened shape for coiling purposes. Later, atthe time of installation at the project site, the flattened pipe willbe formed
13、 into the folded shape when inserted into the existingsewer and conduit rehabilitation.3.2.3 folded pipe, npipe that has been manufactured andcalibrated round, then subsequently cooled and deformed intoa folded shape for use in existing sewer and conduit rehabili-tation (see Fig. 1).3.2.4 formed fie
14、ld sample, nA formed field sample isformed when the folded pipe has been inserted into a mold pipeand expanded with steam heat and pressure1This standard is under the jurisdiction of Committee F17 on Plastic PipingSystems and is the direct responsibility of Subcommittee F17.67 on TrenchlessPlastic P
15、ipeline Technology.Current edition approved March 15, 2006. Published April 2006. Originallyapproved in 1998. Last previous edition approved in 2004 as F 1867 98(2004).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual
16、 Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Uni-Bell PVC Pipe Association, 2655 Villa Creek Drive, Suite155, Dallas, TX 75234.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-
17、2959, United States.3.2.5 formed pipe, na folded pipe that has been insertedinto an existing sewer or conduit and expanded with steam heatand pressure, and, if required by the manufacturer, with asqueegee device or similar device to provide a close fit to theexisting pipe (see Fig. 1).3.2.6 insertio
18、n point, nAn existing manhole, existingaccess shaft, or an excavation that serves as the point ofentrance for the folded pipe into the existing pipe.3.2.7 liner, nPVC formed pipe fully functional as a pipewithin a rehabilitated pipe.3.2.8 termination point, nAn existing manhole, existingaccess shaft
19、, or an excavated pit that serves as the point of exitof the folded pipe from the existing pipe.4. Significance and Use4.1 This practice is for use by designers, and specifiesregulatory agencies, owners, and inspection organizations in-volved in the rehabilitation of non-pressure sewers and con-duit
20、s. Modifications may be required, depending on specificjob conditions, to establish a project specification. The manu-facturer of the product should be consulted for design andinstallation information. Industrial waste disposal lines shouldbe installed only with the specific approval of the cognizan
21、tcode authority, since chemicals not commonly found in drainsand sewers and temperatures in excess of 140 F (60 C) maybe encountered.5. Materials5.1 The folded/formed PVC liner pipe should be made fromPVC compound, meeting all the requirements for cell classi-fication 12111 as defined in Specificati
22、on D 1784 and withminimum physical properties as listed.NOTE 1If required by the user, chemical resistance tests will besupplied by the pipe manufacturer.Tensile Strength Test MethodD 6383600 PSI (25 MPa)Tensile Modulus Test MethodD 638155 000 PSI (1069 MPa)Flexural Strength Test MethodD 7904100 PSI
23、 (28 MPa)Flexural Modulus Test MethodD 790145 000 PSI (1000 MPa)Heat Deflection Test MethodD 648115 F (46 C)Temperature Tested at 264psi(2 MPa)5.1.1 Compounds meeting the above minimum propertiesthat have different cell classifications because one or moreproperties are greater to those of the specif
24、ied compounds arealso acceptable, except modulus in tension shall not exceed280 000 psi.5.2 Rework MaterialClean rework material from this typeof pipe, generated from the manufacturers own pipe produc-tion may be used by the same manufacturer provided that therework material meets all the requiremen
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF18672006STANDARDPRACTICEFORINSTALLATIONOFFOLDEDFORMEDPOLYVINYLCHLORIDEPVCPIPETYPEAFOREXISTINGSEWERANDCONDUITREHABILITATION

链接地址:http://www.mydoc123.com/p-535893.html