ASTM F1336-2015 Standard Specification for Poly(Vinyl Chloride) (PVC) Gasketed Sewer Fittings《装衬垫的聚氯乙烯 (PVC) 污水管配件的标准规格》.pdf
《ASTM F1336-2015 Standard Specification for Poly(Vinyl Chloride) (PVC) Gasketed Sewer Fittings《装衬垫的聚氯乙烯 (PVC) 污水管配件的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1336-2015 Standard Specification for Poly(Vinyl Chloride) (PVC) Gasketed Sewer Fittings《装衬垫的聚氯乙烯 (PVC) 污水管配件的标准规格》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1336 07F1336 15Standard Specification forPoly(Vinyl Chloride) (PVC) Gasketed Sewer Fittings1This standard is issued under the fixed designation F1336; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last r
2、evision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope Scope*1.1 This specification covers requirements and test methods for fabricated or molded poly(vinyl chloride) (PVC) gasketed
3、sewerfittings to be used with piping manufactured to Specifications D3034, F679, F891 or F1760. Fabricated fittings may bemanufactured from pipe, or from a combination of pipe and injection molded parts, or from injection molded parts.1.2 The requirements of this specification are to provide fabrica
4、ted or molded PVC gasketed fittings suitable for non-pressuredrainage of sewage and surface water, as well as applications involving subsurface drainage.NOTE 1Industrial waste lines should be installed only with the specific approval of the governing code authority when using chemicals not commonlyf
5、ound in drains and sewers or temperatures in excess of 140F (60C), or both.1.3 Fittings produced to this specification are intended to be installed with pipe, in accordance with Practice D2321.1.4 The values stated in inch-pound units are to be regarded as the standard. Within the text, the SI units
6、 are given inparentheses. standard. The values given in parentheses are mathematical conversions to SI units that are provided for informationonly and are not considered standard.1.5 The following precautionary caveat pertains to the test method portion only, Section 10, of this specification.This s
7、tandarddoes not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of thisstandard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.2. Referenced Documents2.1
8、ASTM Standards:2D618 Practice for Conditioning Plastics for TestingD1600 Terminology for Abbreviated Terms Relating to PlasticsD1784 Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC)CompoundsD2122 Test Method for Determining Dimensions of Thermo
9、plastic Pipe and FittingsD2321 Practice for Underground Installation of Thermoplastic Pipe for Sewers and Other Gravity-Flow ApplicationsD2444 Test Method for Determination of the Impact Resistance of Thermoplastic Pipe and Fittings by Means of a Tup (FallingWeight)D2564 Specification for Solvent Ce
10、ments for Poly(Vinyl Chloride) (PVC) Plastic Piping SystemsD2749 Symbols for Dimensions of Plastic Pipe FittingsD3034 Specification for Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and FittingsD3212 Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric SealsD4396 Sp
11、ecification for Rigid Poly(Vinyl Chloride) (PVC) and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds forPlastic Pipe and Fittings Used in Nonpressure ApplicationsF412 Terminology Relating to Plastic Piping SystemsF477 Specification for Elastomeric Seals (Gaskets) for Joining Plastic PipeF610/F610M
12、 Practice for Evaluating the Quality of Molded Poly(Vinyl Chloride) (PVC) Plastic Pipe Fittings by the HeatReversion TechniqueF656 Specification for Primers for Use in Solvent Cement Joints of Poly(Vinyl Chloride) (PVC) Plastic Pipe and FittingsF679 Specification for Poly(Vinyl Chloride) (PVC) Large
13、-Diameter Plastic Gravity Sewer Pipe and Fittings1 This specification is under the jurisdiction of ASTM Committee F17 on Plastic Piping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer.Current edition approved May 1, 2007Nov. 1, 2015. Published May 2007December 2015. Original
14、ly approved in 1991. Last previous edition approved in 20022007 asF1336 02.F1336 07. DOI: 10.1520/F1336-07.10.1520/F1336-15.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, re
15、fer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all c
16、hanges accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100
17、Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1F891 Specification for Coextruded Poly(Vinyl Chloride) (PVC) Plastic Pipe With a Cellular CoreF913 Specification for Thermoplastic Elastomeric Seals (Gaskets) for Joining Plastic PipeF1760 Specification for Coextruded Po
18、ly(Vinyl Chloride) (PVC) Non-Pressure Plastic Pipe Having Reprocessed-RecycledContent2.2 Federal Standard:Fed. Std. No. 123 Marking for Shipment (Civil Agencies)32.3 Military Standard:MIL-STD-129 Marking for Shipment and Storage33. Terminology3.1 Definitions are in accordance with Terminology F412 u
19、nless otherwise specified.3.1.1 Abbreviations are in accordance with Terminology D1600, unless otherwise indicated. The abbreviation for poly(vinylchloride) plastic is PVC. The abbreviation for plastic sewer main is PSM.4. Materials and Manufacture4.1 Basic MaterialsThe pipe components for fabricate
20、d fittings shall be made from PVC compounds meeting the cellclassifications indicated under the material section of the pipe standards referenced in 1.1. Molded components or fittings shall bemade from virgin or rework PVC compound having a cell classification of 11432 or 12321 as prescribed in Spec
21、ification 12454or D4396 or 12454 or 13343 as prescribed in Specification D1784. Virgin or rework compounds that have different cellclassifications because one or more properties exceed the minimum requirements of those specified compounds are also acceptable.4.2 Rework MaterialClean rework material
22、generated from the manufacturers own pipe, molded components, or fittingsproduction may be used by the same manufacturer providing the rework material meets the requirements of 4.1 and that the pipe,molded components, or fittings produced meet all the requirements of this specification.5. Miscellane
23、ous Requirements5.1 Gasketed Joining System:5.1.1 The assembled joint shall display no leakage when tested in accordance with the requirements of Specification D3212.5.1.2 The joint assembly shall be in accordance with the fitting manufacturers recommendations. The end of the pipe or fittingspigot s
24、hall not damage or dislodge the gasket during insertion. Lubricant is required on the spigot and sometimes additionally onthe gasket. All surfaces of the joint that make contact with the gasket shall be smooth and free of imperfections, ridges, fractures,or cracks that could adversely affect the sea
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF13362015STANDARDSPECIFICATIONFORPOLYVINYLCHLORIDEPVCGASKETEDSEWERFITTINGS 衬垫 聚氯乙烯 PVC 污水 配件 标准 规格

链接地址:http://www.mydoc123.com/p-534681.html