1、Designation: E 788 97 (Reapproved 2003)Standard Specification forPipet, Blood Diluting1This standard is issued under the fixed designation E 788; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number i
2、n parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification covers requirements for glass reusablebloo
3、d diluting pipets that are used for performing red and whitecell corpuscle determinations.2. Referenced Documents2.1 ASTM Standards:E 694 Specification for Volumetric Ware2E 920 Specification for Commercially Packaged LaboratoryApparatus2E 921 Specification for Export Packaged Laboratory Appa-ratus2
4、E 1133 Practice for Performance Testing of Packaged Labo-ratory Apparatus for United States Government Procure-ments2E 1157 Specification for Sampling and Testing of ReusableLaboratory Glassware23. Classification3.1 This specification covers two different pipet designs andpermissible alternatives.3.
5、1.1 Red and white cell blood diluting pipets (see Fig. 1).3.1.2 Permissible alternative designs (see Fig. 2).4. Materials4.1 The pipets shall be made of common spirit bore whiteback tubing or clear glass with a white stripe applied to theouter surface of the tubing.4.2 The beads shall be made of gla
6、ss or ceramic composi-tion and shall be of red, clear, or white coloring.5. Dimensions and Permissible Variations5.1 DesignThe red and white cell blood dilution pipetsshall consist of a small uniform bore glass tube which shallhave a bulb of proper size near the proximal end (see Fig. 1).As an alter
7、native, the pipets may be constructed of three piecesof glass that are fused together to form a one-piece pipet (seeFig. 2). The bulb shall contain a nonspherical glass or ceramicbead sufficiently large enough to prevent its being impacted inthe constriction portion of the bulb. The cross section of
8、 thepipet at any point shall be circular. The distal end of the whitecell pipet shall be pulled to a point and then ground andpolished to a tapered tip. The distal end of the red cell pipetshall be ground and polished to a tapered tip. The insidediameter (ID) of the pipet bore at the tip end of the
9、white cellpipet shall be 0.2 to 0.5 mm. The external diameter of theground and polished tip shall not exceed 2.0 mm. The overalllength of both pipets shall be 104 to 121 mm. The proximal endmay be of funnel design, with an exterior taper, or ground andpolished with a taper of sufficient angle to per
10、mit application ofa rubber suction tube or other suction device (see Fig. 2).5.2 CapacityThe capacity of the red cell pipet bulb shallbe 0.8 to 1.2 cm3and the capacity of the white cell bulb shall be0.2 to 0.4 cm3. The capacity of the red cell pipet stem (bulb todistal end) shall be 0.008 to 0.012 c
11、m3and the capacity of thewhite cell pipet stem shall be 0.02 to 0.04 cm3.5.3 Capacity Markings:5.3.1 Pipet Bulb MarkingsThe red and white cell pipetbulb capacity shall be confined to and indicated by calibrationlines on the pipet. These lines shall be located on both sides ofthe bulb and shall be wi
12、thin 2 mm to 6 mm above the bulb(proximal end) and within 3 mm to 6 mm below the bulb (distalend). The exact manner for measuring these line placements isspecified in Fig. 1.5.3.2 Pipet Stem MarkingsThe graduation lines on thestem of the red and white cell pipets shall be equally dividedinto two or
13、ten divisions. If there are two divisions, the twocalibration lines on the stem will be numbered 0.5 and 1. Ifthere are ten divisions, the ten calibration lines will benumbered 0.5 on the fifth line and 1 on the tenth linerespectively. The top line (above bulb at the proximal end)shall be numbered 1
14、01 on the red cell pipet and 11 on the whitecell pipet, representing stem and bulb volume collectively. Atthe option of the manufacturer, pipet stems may be graduatedwith split lines or partial length lines (see Fig. 2).1This specification is under the jurisdiction of ASTM Committee E41 onLaboratory
15、 Apparatus and is the direct responsibility of Subcommittee E41.01 onGlass Apparatus.Current edition approved Nov. 10, 1997. Published February 1998. Originallypublished as E 788 81. Last previous edition E 788 93.2Annual Book of ASTM Standards, Vol 14.02.1Copyright ASTM International, 100 Barr Harb
16、or Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.4 Graduation LinesAll graduation lines on the red andwhite cell pipets shall be at right angles to the pipet axis andparallel to each other. The thickness of the graduation linesshall not exceed 0.4 mm.5.5 AccuracyThe red and w
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME78819972003STANDARDSPECIFICATIONFORPIPETBLOODDILUTING 血液 稀释 管用 标准规范 PDF

链接地址:http://www.mydoc123.com/p-533524.html