ASTM E514-2006 Standard Test Method for Water Penetration and Leakage Through Masonry《砖石建筑的水渗入和渗漏的标准试验方法》.pdf
《ASTM E514-2006 Standard Test Method for Water Penetration and Leakage Through Masonry《砖石建筑的水渗入和渗漏的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E514-2006 Standard Test Method for Water Penetration and Leakage Through Masonry《砖石建筑的水渗入和渗漏的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 514 06Standard Test Method forWater Penetration and Leakage Through Masonry1This standard is issued under the fixed designation E 514; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A numb
2、er in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This laboratory test method2provides a procedure fordete
3、rmining the resistance to water penetration and leakagethrough unit masonry subjected to wind-driven rain.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety an
4、d health practices and determine the applica-bility of regulatory limitations prior to use. For a specifichazard statement see Section 6.2. Referenced Documents2.1 ASTM Standards:3C 1232 Terminology of Masonry2.2 American Concrete Institute Standard:4ACI 530/ASCE 5/TMS 402 Building Code Requirements
5、for Masonry StructuresACI 530.1/ASCE 6/TMS 602 Specifications for MasonryStructures3. Terminology3.1 For definitions of terms used in this test method, refer toTerminology C 1232.4. Significance and Use4.1 This test method provides information that aids inevaluating the effect of four principal vari
6、ables: materials,coatings, wall design, and workmanship.4.2 Water penetration and leakage through masonry issignificantly affected by air pressure in the test chamber. Datafrom tests made at different pressures are not comparable.4.3 The performance of a masonry wall is a function ofmaterials, const
7、ruction, wall design, and maintenance. Inservice the performance will also depend on the rigidity ofsupporting structure and on the resistance of components todeterioration by various causes, such as corrosion, vibration,thermal expansion and contraction, curing, and others. It isimpossible to simul
8、ate the complex conditions encountered inservice, such as variations in wind velocity, negative pressure,and lateral or upward moving air and water. Factors such aslocation, exposure, and wall openings should be considered.4.4 Given the complexity of variables noted above, this testmethod establishe
9、s comparative behavior between variousmasonry wall constructions in a given laboratory.4.5 Even when a single laboratory tests the same walldesign utilizing the same wall materials and the same construc-tion practices, variables such as the level of skill of the masonbuilding the specimen, the tempe
10、rature and humidity in thelaboratory at the time of construction, curing of the specimen,the moisture contents of the materials used to build thespecimen, and even the use or lack of use of a lime and waterwash on the back of the specimen can affect the results of thetest making reliable comparisons
11、 dubious. For these reasonsand the multi-variables listed in 4.1, 4.2, and 4.3, a meaningful,useful, absolute wall leakage rating standard is impractical anddiscouraged.5. Apparatus5.1 Test ChamberUse a test chamber similar to thatshown in Fig. 1 and Fig. 2. Provide an opening with aminimum area of
12、1.08 m2(12 ft2). For example, 900 mm (36in.) wide and 1200 mm (48 in.) high is suitable. Line the edgesof the chamber in contact with the specimen with a closed-cellcompressible gasket material or appropriate sealant. Provide anobservation port in the face of the chamber. Provide a 19.0-mm(34-in.) d
13、iameter corrosion-resistant spray pipe with a singleline of 1.0-mm (0.04-in.) diameter holes spaced 25.0 mm (1in.) apart.1This test method is under the jurisdiction of ASTM Committee C15 onManufactured Masonry Units and is the direct responsibility of SubcommitteeC15.04 on Research.Current edition a
14、pproved Dec. 1, 2006. Published January 2007. Originallyapproved in 1974. Last previous edition approved in 2005 as E 514 05c.2This test method is based upon those used by the National Bureau of Standardsand described in NBS Report BMS7, “Water Permeability of Masonry Walls,” 1933,and NBS Report BMS
15、82, “Water Permeability of Walls Built of Masonry Units,”1942.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website
16、.4Published by The Masonry Society, www.masonrysociety.org; American Con-crete Institute, www.aci-int.org; and American Society of Civil Engineers,www.asce.org.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Co
17、nshohocken, PA 19428-2959, United States.5.2 Fixtures and Appurtenances to ChamberFixtures andappurtenances to the chamber shall include an air line withmanometer, a water line with valves, a flow meter andmanometer and a water drain pipe at the bottom of theFIG. 1 Isometric Projection of Testing Ch
18、amberFIG. 2 General Arrangement of Water Penetration Testing Chamber SystemE514062chamber. Position the water spray pipe so that the waterimpinges the specimen not more than 75.0 mm (3.00 in.) belowthe top of the test chamber.NOTE 1A drain pipe that discharges into a reservoir equipped with anadjust
19、able depth air outlet pipe and top baffles has been found to reducesurge.5.3 ManometerMeasure the air pressure in the chamberusing a manometer or other device capable of measuring airpressures of at least 51 mm (2.0 in.) of water (71.7 kPa) (10.4psf) to an accuracy of 2.5 mm (0.1 in.) or 3.6 kPa (0.
20、52 psf).Connect the manometer or other device to the chamber awayfrom the air inlet so that the air flow will not significantlyinfluence the pressure reading.5.4 Other equipment includes devices for handling thespecimen and measuring time, water quantities, temperature,and humidity.6. Hazards6.1 The
21、 use of this test method will require careful designconsideration of both air chamber and support of the wallsystem to avoid possible injury due to equipment or specimenfailure.7. Temperature and Humidity Conditions7.1 Maintain the air in the laboratory at a temperature of 246 8C (75 6 15F) and a re
22、lative humidity of 55 % 6 25 %.8. Test Specimens8.1 Masonry MaterialsMasonry and associated materialsshall be representative of the construction or the materials thatare being considered. Precondition all materials by storing inlaboratory environment for not less than 5 days before use.8.2 Size of T
23、est WallsThe height and length of thespecimen shall provide a minimum of 1.08 m2(12 ft2) exposedto the test, plus at least a 200-mm (8-in.) overlap on all edges.The minimum height or length of the specimen shall be 1.22 m(4 ft). The length of the specimen shall be such that at least onehead joint in
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME5142006STANDARDTESTMETHODFORWATERPENETRATIONANDLEAKAGETHROUGHMASONRY 砖石 建筑 渗入 渗漏 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-532929.html