1、Designation: E514/E514M 14aStandard Test Method forWater Penetration and Leakage Through Masonry1This standard is issued under the fixed designation E514/E514M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the year of last revis
2、ion. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope*1.1 This laboratory test method2provides a pr
3、ocedure fordetermining the resistance to water penetration and leakagethrough unit masonry subjected to wind-driven rain. This testmethod is not identical to and the results are not the same asfield standard Test Method C1601. This test method measuresthrough-wall water penetration, whereas Test Met
4、hod C1601only measures surface water penetration.1.2 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from t
5、he two systems may result in non-conformancewith the standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica
6、-bility of regulatory limitations prior to use. For a specifichazard statement, see Section 6.2. Referenced Documents2.1 ASTM Standards:3C270 Specification for Mortar for Unit MasonryC1232 Terminology of MasonryC1601 Test Method for Field Determination of Water Pen-etration of Masonry Wall Surfaces2
7、.2 The Masonry Society Standards:4TMS 402/ACI 530ASCE 5 Building Code Requirementsfor Masonry StructuresTMS 602/ACI 530.1ASCE 6 Specifications for MasonryStructures3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 dampness, nvisual change in the appearance of amaterial due to th
8、e presence of water.3.1.2 surface water penetration, npassage of waterthrough the exterior face of the masonry.3.1.3 through-wall water penetration, npassage of waterthrough a wall and appearance of the water on the interior faceof the masonry.3.1.4 water penetration, nwater that passes into orthrou
9、gh the masonry.3.1.5 wind-driven rain, nrain water that is directed againstthe surface of the wall by wind.3.2 For definitions of other terms used in this test method,refer to Terminology C1232.4. Significance and Use4.1 This test method provides information that aids inevaluating the effect of four
10、 principal variables: materials,coatings, wall design, and workmanship.4.2 Water penetration and leakage through masonry issignificantly affected by air pressure in the test chamber. Datafrom tests made at different pressures are not comparable.4.3 The performance of a masonry wall is a function ofm
11、aterials, construction, wall design, and maintenance. Inservice the performance will also depend on the rigidity ofsupporting structure and on the resistance of components todeterioration by various causes, such as corrosion, vibration,thermal expansion and contraction, curing, and others. It isimpo
12、ssible to simulate the complex conditions encountered in1This test method is under the jurisdiction of ASTM Committee C15 onManufactured Masonry Units and is the direct responsibility of SubcommitteeC15.04 on Research.Current edition approved July 1, 2014. Published July 2014. Originally approvedin
13、1974. Last previous edition approved in 2014 as E514/E514M 14. DOI:10.1520/E0514_E0514M-14A.2This test method is based upon those used by the National Bureau of Standardsand described in NBS Report BMS7, “Water Permeability of Masonry Walls,” 1933,and NBS Report BMS82, “Water Permeability of Walls B
14、uilt of Masonry Units,”1942.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Published by The Masonry Society
15、, www.masonrysociety.org; American Con-crete Institute, www.aci-int.org; and American Society of Civil Engineers,www.asce.org.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United St
16、ates1service, such as variations in wind velocity, negative pressure,and lateral or upward moving air and water. Factors such aslocation, exposure, and wall openings should be considered.4.4 Given the complexity of variables noted above, this testmethod establishes comparative behavior between vario
17、usmasonry wall constructions in a given laboratory.4.5 Even when a single laboratory tests the same walldesign utilizing the same wall materials and the same construc-tion practices, variables such as the level of skill of the masonbuilding the specimen, the temperature and humidity in thelaboratory
18、 at the time of construction, curing of the specimen,the moisture contents of the materials used to build thespecimen, and even the use or lack of use of a lime and waterwash on the back of the specimen can affect the results of thetest making reliable comparisons dubious. For these reasonsand the m
19、ulti-variables listed in 4.1, 4.2, and 4.3, a meaningful,useful, absolute wall leakage rating standard is impractical anddiscouraged.4.6 This test method is similar to but distinct from field TestMethod C1601. This laboratory test method is designed to testlaboratory fabricated wall specimens. Field
20、 Test MethodC1601 is designed to test in-situ walls. This test methodmeasures the water that has penetrated into and through themasonry specimen and is collected. Test Method C1601determines water penetration of the masonry at its surface.Results from Test Method C1601 and Test Method E514/E514M are
21、 not the same.5. Apparatus5.1 Test ChamberUse a test chamber similar to that shownin Fig. 1 and Fig. 2. Provide an opening with a minimum areaof 1.08 m212 ft2. For example, 900 mm 36 in. wide and1200 mm 48 in. high is suitable. Line the edges of thechamber in contact with the specimen with a closed-
22、cellcompressible gasket material or appropriate sealant. Provide anobservation port in the face of the chamber. Provide a 19.0-mm34-in. diameter corrosion-resistant spray pipe with a singleline of 1.0-mm 0.04-in. diameter holes spaced 25.0 mm1 in. apart.5.2 Fixtures and Appurtenances to ChamberFixtu
23、res andappurtenances to the chamber shall include an air line withmanometer, a water line with valves, a flow meter andmanometer and a water drain pipe at the bottom of thechamber. Position the water spray pipe so that the waterimpinges the specimen not more than 75.0 mm 3.00 in. belowthe top of the
24、 test chamber.NOTE 1A drain pipe that discharges into a reservoir equipped with anadjustable depth air outlet pipe and top baffles has been found to reducesurge.5.3 ManometerMeasure the air pressure in the chamberusing a manometer or other device capable of measuring airpressures of at least 51 mm 2
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME514E514M2014A7865STANDARDTESTMETHODFORWATERPENETRATIONANDLEAKAGETHROUGHMASONRY 砖石 建筑 渗水 渗漏 标准 试验

链接地址:http://www.mydoc123.com/p-532928.html