ASTM E3143-2018 Standard Practice for Performing Cryo-Transmission Electron Microscopy of Liposomes《脂质体低温透射电子显微镜检查的标准实施规程》.pdf
《ASTM E3143-2018 Standard Practice for Performing Cryo-Transmission Electron Microscopy of Liposomes《脂质体低温透射电子显微镜检查的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E3143-2018 Standard Practice for Performing Cryo-Transmission Electron Microscopy of Liposomes《脂质体低温透射电子显微镜检查的标准实施规程》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E3143 18Standard Practice forPerforming Cryo-Transmission Electron Microscopy ofLiposomes1This standard is issued under the fixed designation E3143; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revi
2、sion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers procedures for vitrifying and re-cording images of a suspension of liposomes with a cryo-transmission elec
3、tron microscope (cryo-TEM) for the purposeof evaluating their shape, size distribution and lamellarity forquality assessment. The sample is vitrified in liquid ethane ontospecially prepared holey, ultra-thin, or continuous carbon TEMgrids, and imaged in a cryo-holder placed in a cryo-TEM.1.2 The val
4、ues stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate sa
5、fety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment o
6、f International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2E1617 Practice for Reporting Particle Size CharacterizationData2.2 ISO Standards:313322-1 Particle Size Analysis Image A
7、nalysis Methods Static Image Analysis Methods3. Terminology3.1 Definitions:3.1.1 anti-contaminator, na specially designed devicebuilt into the column of a cryo-transmission electron micro-scope designed to pull contamination produced by outgassingwithin the column away from the frozen specimen durin
8、gimaging. The device is cooled with liquid nitrogen to atemperature below that of the specimen creating a coldersurface for contamination to build on.3.1.2 carbon evaporator, na device used to evaporatecarbon in a high vacuum chamber generally by applyingcurrent through two carbon rods pressed again
9、st one another,with one rod being sharpened in order to provide resistance tothe current; this causes the rods to heat up and evaporatecarbon. The same device can also be used as a glow dischargedevice (3.1.15) in order to glow discharge surfaces.3.1.3 continuous carbon grid, na copper electron micr
10、o-scope grid coated with a self-supporting layer of continuouscarbon over the square mesh of the grid.3.1.4 copper electron microscope grid, ncommonly re-ferred to as an “EM grid,” a thin 3-mm diameter copper foildisk, usually manufactured with a pattern of square holescalled a mesh through which im
11、aging is conducted in anelectron microscope. The number, pattern, and shape of theholes can vary depending on imaging conditions and samplerequirements.3.1.5 cryo-grid storage device, nany device used to storecryo-EM grids indefinitely in a liquid nitrogen dewar.3.1.6 cryo-TEM, nalso referred to sim
12、ply as cryo-EM, orcryo electron microscopy, the process of imaging frozenvitrified samples using a cryo-transmission electron micro-scope.3.1.7 cryo-TEM holder, na liquid nitrogen refrigerateddevice specifically designed to hold and maintain a preparedgrid containing a frozen, hydrated, vitrified sp
13、ecimen in acryo-TEM while imaging is conducted.3.1.8 cryo-TEM plunger, na device used to vitrify asample onto a holey, ultra-thin, or continuous carbon grid forcryo-TEM by plunging the grid containing a thin layer ofaqueous sample into an ethane slush or other cryogen(s). There1This practice is unde
14、r the jurisdiction of ASTM Committee E56 on Nanotech-nology and is the direct responsibility of Subcommittee E56.02 on Physical andChemical Characterization.Current edition approved Feb. 1, 2018. Published February 2018. DOI: 10.1520/E1343-18.2For referenced ASTM standards, visit the ASTM website, w
15、ww.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from International Organization for Standardization (ISO), ISOCentral Secretariat, BIBC II, Chemin de Bland
16、onnet 8, CP 401, 1214 Vernier,Geneva, Switzerland, http:/www.iso.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization
17、established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1are many types of plunger designs both homemade andcommercial. The simplest is the homemade guilloti
18、ne type (seeFig. 3(B), 8.3).3.1.9 cryo-transmission electron microscope, na speciallydesigned transmission electron microscope (see 3.1.25) ca-pable of imaging frozen vitrified specimens under low electrondose conditions in order to prevent beam-induced specimendamage.3.1.10 electron micrograph, nth
19、e individual image re-corded by the electron microscope as data are collected.3.1.11 electron tomography, nthe process of using imagesderived from an electron microscope in which the images wererecorded of a sample through an incremental series of tiltangles that are then used with image analysis so
20、ftware toreconstruct the structure of the specimen in 3D.3.1.12 ethane, nchemical formula C2H6. A colorless,odorless flammable gas.3.1.13 forceps, na very fine pointed pair of tweezers orpincer used to pick up electron microscope grids.3.1.14 glow discharge, na plasma generated by passing anelectric
21、 current through a low-pressure gas environment withina chamber, usually a bell jar and with respect to this standard,is used to clean and statically charge the carbon surface coatingof copper electron microscope grids in order to make themhydrophilic so that they will wet during sample application.
22、3.1.15 glow discharge device, na device, such as a carbonevaporator (see 3.1.2), designed to generate a glow dischargeplasma.3.1.16 hang time, vthe amount of time after blotting of thesample from the prepared grid, prior to plunging the grid intothe liquid ethane for vitrification.3.1.17 holey carbo
23、n grid, na copper electron microscopegrid specially prepared for cryo-TEM consisting of a thinelectron semi-transparent carbon film containing small holesthat is suspended over the larger mesh of square holes of thecopper electron microscope grid (see Fig. 3(A), 8.2.1).3.1.18 image analysis, nthe pr
24、ocess of analyzing digitalimages with computer software for the purpose of extractingmeaningful information from the data, for example, a sizedistribution.3.1.19 liposomes, nmicrovesicles composed of a bilayerand/or a concentric series of multiple bilayers separated byaqueous compartments formed by
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME31432018STANDARDPRACTICEFORPERFORMINGCRYOTRANSMISSIONELECTRONMICROSCOPYOFLIPOSOMES 脂质体 低温 透射 电子显微镜

链接地址:http://www.mydoc123.com/p-532374.html