ASTM E2657-2009 Standard Test Method for Determination of Endotoxin Concentrations in Water-Miscible Metalworking Fluids《水混合金属工作液中内霉素测定的试验方法》.pdf
《ASTM E2657-2009 Standard Test Method for Determination of Endotoxin Concentrations in Water-Miscible Metalworking Fluids《水混合金属工作液中内霉素测定的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2657-2009 Standard Test Method for Determination of Endotoxin Concentrations in Water-Miscible Metalworking Fluids《水混合金属工作液中内霉素测定的试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2657 09An American National StandardStandard Test Method forDetermination of Endotoxin Concentrations in Water-Miscible Metalworking Fluids1This standard is issued under the fixed designation E 2657; the number immediately following the designation indicates the year oforiginal adopti
2、on or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers quantitative methods for thesampling and determina
3、tion of bacterial endotoxin concentra-tions in water miscible metalworking fluids (MWF).1.2 Users of this test method need to be familiar with thehandling of MWF.1.3 This test method gives an estimate of the endotoxinconcentration in the sampled MWF.1.4 This test method replaces E 2250.1.5 This test
4、 method seeks to minimize inter-laboratoryvariation of endotoxin data but does not ensure uniformity ofresults.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safe
5、ty and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 2881 Classification for Metal Working Fluids and RelatedMaterialsD 4840 Guide for Sample Chain-of-Custody ProceduresE 1497 Practice for Selection and Safe Use
6、of Water-Miscible and Straight Oil Metal Removal FluidsE 1542 Terminology Relating to Occupational Health andSafety2.2 Government Standard:329 CFR 1910.1450 Occupational Exposure to HazardousChemicals in Laboratories29 CFR 1910.1000 Air Contaminants2.3 Other Documents:Criteria Document for a Recomme
7、nded Standard: Occupa-tional Exposure to Metalworking Fluids, 1998NIOSH Manual of Analytical Methods (NMAM), 4th ed.,Eller and Cassinelli, Eds., 19943. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 control standard endotoxin (CSE), na purifiedpreparation of endotoxin based on t
8、he USP Reference StandardEndotoxin (RSE); used in laboratories to prepare standardsolutions.3.1.2 endotoxin, na lipopolysaccharide derived from theouter membrane of Gram-negative bacteria.3.1.3 endotoxin unit (EU), na biological potency unitequivalent to the FDA Reference Standard Endotoxin (RSE).3.
9、1.3.1 DiscussionThe current RSE (EC-6) is equivalentto 1ng = 10 EU.3.1.4 geometric mean (GM), nthe central tendency of aset of numbers expressed as the nth root of their product.3.1.5 geometric standard deviation (GSD), nthe spread ofdata in a set of numbers expressed as a geometric mean.3.1.6 gram-
10、negative bacteria, nprokaryotic cells thathave a complex cell wall structure that stains characteristicallywhen subjected to the differential Gram staining procedure.3.1.7 inhibition/enhancement phenomenon, nconditionsor artifacts in sample solutions that cause endotoxin concen-tration data from LAL
11、 assays to be less than or more than theconcentration of endotoxin actually present in a given aqueoussample.3.1.8 Limulus amebocyte lysate (LAL) assay, na biologi-cal assay dependent on a series of cascading enzyme reactionsthat occur when Limulus blood cell (amebocyte) lysate com-bines with endoto
12、xin.3.1.9 metalworking fluid (MWF), nany fluid used for thepurpose of cooling or treating metal surfaces during metalremoval, metal forming or surface protection or preservation.3.1.10 metal removal fluid (MRF), nany fluid in thesubclass of metalworking fluids used to cut, or otherwise takeaway mate
13、rial or piece of stock.1This test method is under the jurisdiction of ASTM Committee E34 onOccupational Health and Safety and is the direct responsibility of SubcommitteeE34.50 on Health and Safety Standards for Metal Working Fluids.Current edition approved May 1, 2009. Published June 2009.2For refe
14、renced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from U.S. Government Printing Office Superintendent of Docu
15、ments,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http:/www.access.gpo.gov.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.1.10.1 DiscussionMetal removal fluids include straightor neat oils (see D 2881), not inten
16、ded for further dilution withwater, and water miscible soluble oils, semisynthetics andsynthetics, which are intended to be diluted with water beforeuse. Metal removal fluids become contaminated during use inthe workplace with a variety of workplace substances includ-ing, but not limited to, abrasiv
17、e particles, tramp oils, cleaners,dirt, metal fines and shavings, dissolved metal and hard watersalts, bacteria, fungi, microbiological decay products, andwaste. These contaminants can cause changes in the lubricityand cooling ability of the metal removal fluid as well as havethe potential to advers
18、ely affect the health and welfare ofemployees in contact with the contaminated metal removalfluid.3.1.11 operator-dependent assay, nan assay performed bya technician in such a manner to cause significant influence(s)on the resultant data.3.1.12 pyrogen-free (PF), adjmaterial(s) devoid of mea-surable
19、 endotoxin activity.3.1.13 pyrogen-free water (PFW), nprocessed water thatis devoid of measurable endotoxin activity.3.1.14 sensitivity range, na span of endotoxin measure-ments expressed as EU/mL or l.4. Summary of Test Method4.1 Serial dilutions of CSE in PFW in borosilicate glass testtubes are pr
20、epared to construct a calibration curve.4.2 The metalworking fluid sample is sonicated, centri-fuged, and the supernatant retained.4.3 Triplicates of the sample supernatant, standard serialdilutions, blanks, and positive control solutions are subjected tothe kinetic chromogenic LAL assay.4.4 The rea
21、ction of Limulus amebocyte lysate with sampleendotoxin imparts a proportional yellow color to the analytesolution that is measured photometrically at 405 nm.4.5 The measured endotoxin concentration is reported asEU/mL.5. Significance and Use5.1 The determination of endotoxin concentrations in met-al
22、working fluids is a parameter that can be used in decision-making for prudent fluid management practices (fluid draining,cleaning, recharging or biocide dosages).5.2 This test method provides a test method for analystswho perform quantitative endotoxin analyses of water-misciblemetalworking fluids.6
23、. Interferences6.1 Data from samples analyzed by LAL methodologies areprone to variations due to batch differences in lysatecomposition/processing, non-optimal pH and temperatures ofassay solutions.6.2 In the event that the phenomenon of inhibition/enhancement influences this test method, endotoxin
24、concentra-tion data will be less than or more than actual concentrationspresent in a given metalworking fluid sample.6.3 LALassays are highly influenced by the skill/experiencelevel of the analyst.7. Apparatus7.1 Sampling:7.1.1 Sample Collection Container, pyrogen-free, wide-mouth, stainless steel s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME26572009STANDARDTESTMETHODFORDETERMINATIONOFENDOTOXINCONCENTRATIONSINWATERMISCIBLEMETALWORKINGFLUIDS

链接地址:http://www.mydoc123.com/p-531633.html