《ASTM E2655-2008 Standard Guide for Reporting Uncertainty of Test Results and Use of the Term Measurement Uncertainty in ASTM Test Methods《ASTM试验方法中术语测量不确定性的使用和试验结果不确定性的报告用标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2655-2008 Standard Guide for Reporting Uncertainty of Test Results and Use of the Term Measurement Uncertainty in ASTM Test Methods《ASTM试验方法中术语测量不确定性的使用和试验结果不确定性的报告用标准指南》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2655 08Standard Guide forReporting Uncertainty of Test Results and Use of the TermMeasurement Uncertainty in ASTM Test Methods1This standard is issued under the fixed designation E 2655; the number immediately following the designation indicates the year oforiginal adoption or, in the
2、 case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide provides concepts necessary for understand-ing the term “uncertainty” when a
3、pplied to a quantitative testresult. Several measures of uncertainty can be applied to agiven measurement result; the interpretation of some of thecommon forms is described.1.2 This guide describes methods for expressing test resultuncertainty and relates these to standard statistical methodol-ogy.
4、Relationships between uncertainty and concepts of preci-sion and bias are described.1.3 This guide also presents concepts needed for a labora-tory to identify and characterize components of method per-formance. Elements that an ASTM method can include toprovide guidance to the user on estimating unc
5、ertainty for themethod are described.1.4 The system of units for this guide is not specified.Dimensional quantities in the guide are presented only asillustrations of calculation methods and are not binding onproducts or test methods treated.1.5 This standard does not purport to address all of thesa
6、fety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E29 Practice for Using Signifi
7、cant Digits in Test Data toDetermine Conformance with SpecificationsE 122 Practice for Calculating Sample Size to Estimate,With Specified Precision, the Average for a Characteristicof a Lot or ProcessE 141 Practice for Acceptance of Evidence Based on theResults of Probability SamplingE 177 Practice
8、for Use of the Terms Precision and Bias inASTM Test MethodsE 456 Terminology Relating to Quality and StatisticsE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE 2554 Practice for Estimating and Monitoring the Uncer-tainty of Test Results of a Test Met
9、hod in a SingleLaboratory Using a Control Sample Program2.2 Other Standard:ISO 17025 General Requirements for the Competence ofTesting and Calibration Laboratories33. Terminology3.1 DefinitionsAdditional statistical terms are defined inTerminology E 456.3.1.1 accepted reference value, na value that
10、serves as anagreed-upon reference for comparison, and which is derivedas: (1) a theoretical or established value, based on scientificprinciples, (2) an assigned or certified value, based on experi-mental work of some national or international organization, or(3) a consensus or certified value, based
11、 on collaborativeexperimental work under the auspices of a scientific orengineering group. E 1773.1.2 error of result, na test result minus the acceptedreference value of the characteristic.3.1.3 expanded uncertainty, U, nuncertainty reported as amultiple of the standard uncertainty.3.1.4 random err
12、or of result, na component of the errorthat, in the course of a number of test results for the samecharacteristic, varies in an unpredictable way.3.1.4.1 DiscussionUncertainty due to random error can bereduced by averaging multiple test results.3.1.5 sensitivity coeffcient, ndifferential effect of t
13、hechange in a factor on the test result.1This guide is under the jurisdiction of ASTM Committee E11 on Quality andStatistics and is the direct responsibility of Subcommittee E11.20 on Test MethodEvaluation and Quality Control.Current edition approved Oct. 1, 2008. Published November 2008.2For refere
14、nced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd
15、 St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.1.6 standard uncertainty, u, nuncertainty reported as thestandard deviation of the estimated value of the quantitysubject to mea
16、surement.3.1.7 systematic error of result, na component of the errorthat, in the course of a number of test results for the samecharacteristic, remains constant or varies in a predictable way.3.1.7.1 DiscussionSystematic errors and their causes maybe known or unknown. When causes are known, systemat
17、icerror can sometimes be reduced by incorporating correctionsinto the calculation of the test result.3.1.8 uncertainty, nan indication of the magnitude oferror associated with a value that takes into account bothsystematic errors and random errors associated with the mea-surement or test process.3.1
18、.9 uncertainty budget, na tabular listing of uncertaintycomponents for a given measurement process giving themagnitudes of contributions to uncertainty of the result fromthose sources.3.1.10 uncertainty component, na source of error in a testresult to which is attached a standard uncertainty.4. Sign
19、ificance and Use4.1 Part A of the “Blue Book,” Form and Style for ASTMStandards, introduces the statement of measurement uncer-tainty as an optional part of the report given for the result ofapplying a particular test method to a particular material.4.2 Preparation of uncertainty estimates is a requ
20、irement forlaboratory accreditation under ISO 17025. This guide describessome of the types of data that the laboratory can use as thebasis for reporting uncertainty.5. Concepts for Reporting Uncertainty of Test Results5.1 Uncertainty is part of the relationship of a test result tothe property of int
21、erest for the material tested. When a testprocedure is applied to a material, the test result is a value fora characteristic of the material. The test result obtained willusually differ from the actual value for that material. Multiplecauses can contribute to the error of result. Errors of samplinga
22、nd effects of sample handling make the portion actually testednot identical to the material as a whole. Imperfections in thetest apparatus and its calibration, environmental, and humanfactors also affect the result of testing. Nonetheless, aftertesting has been completed, the result obtained will be
23、 used forfurther purposes as if it were the actual value. Reportingmeasurement uncertainty for a test result is an attempt toestimate the approximate magnitude of all these sources oferror. In common cases the measurement will be reported in theform x 6 u, in which x represents the test result and u
24、represents the uncertainty associated with x.5.2 Practice E 177 describes precision and bias. Uncertaintyis a closely related but not identical concept. The primarydifference between concepts of precision and of uncertainty isthe object that they address. Precision (repeatability andreproducibility)
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME26552008STANDARDGUIDEFORREPORTINGUNCERTAINTYOFTESTRESULTSANDUSEOFTHETERMMEASUREMENTUNCERTAINTYINASTMTESTMETHODSASTM

链接地址:http://www.mydoc123.com/p-531629.html