1、Designation: E 2544 07aStandard Terminology forThree-Dimensional (3-D) Imaging Systems1This standard is issued under the fixed designation E 2544; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number
2、in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This terminology contains common terms, definitions ofterms, descriptions of terms, nomenclature, and acronymsassociated with three-dimension
3、al (3-D) imaging systems in aneffort to standardize terminology used for 3-D imaging sys-tems.1.2 The definitions of the terms presented in 3.1 are ob-tained from various standard documents developed by variousstandards development organizations. The intent is not tochange these universally accepted
4、 definitions but to gather, ina single document, terms and their definitions that may be usedin current or future standards for 3-D imaging systems.1.2.1 In some cases, definitions of the same term from twostandards have been presented to provide additional reference.The text in parentheses to the r
5、ight of each defined term is thename (and, in some cases, the specific section) of the source ofthe definition associated with that term.1.3 The definitions in 3.2 are specific terms developed bythis committee for 3-D imaging systems.1.4 A definition in this terminology is a statement of themeaning
6、of a word or word group expressed in a singlesentence with additional information included in notes ordiscussions.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate s
7、afety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1The subcommittee responsible for this standard will reviewdefinitions on a five-year basis to determine if the definition is stillappropriate as stated. Revisions will be made when determined nec
8、essary.2. Referenced Documents2.1 ASTM Standard:2E 456 Terminology Relating to Quality and Statistics2.2 ASME Standard:3B89.4.19 Performance Evaluation of Laser Based SphericalCoordinate Measurement Systems2.3 ISO Standard:4VIM, International Vocabulary of Basic and General Termsin MetrologyISO 1114
9、61 Lasers and laser-related equipment Testmethods for laser beam widths, divergence angles andbeam propagation ratios Part 1: Stigmatic and simpleastigmatic beams2.4 NIST/SEMATECH Standard:5NIST/SEMATECH e-Handbook of Statistical Methods3. Terminology3.1 Definitions:accuracy of measurement, nclosene
10、ss of the agreementbetween the result of a measurement and a true value of themeasurand. (VIM 3.5)DISCUSSION(1) Accuracy is a qualitative concept.(2) The term “precision” should not be used for “accuracy.”angular increment, nthe angle between samples, Da, whereDa = ai ai1, in either the azimuth or e
11、levation directions(or a combination of both) with respect to the instrumentsinternal frame of reference.DISCUSSIONFor scanning instruments, the angular increment mayalso be known as the angle step size.bias (of a measuring instrument), nsystematic error of theindication of a measuring instrument. (
12、VIM 3.25)DISCUSSIONThe bias of a measuring instrument is normally esti-mated by averaging the error of indication over an appropriate numberof repeated measurements.1This terminology is under the jurisdiction of Committee E57 on 3D ImagingSystems and is the direct responsibility of Subcommittee E57.
13、01 on Terminology.Current edition approved Aug. 1, 2007. Published September 2007. Originallyapproved in 2007. Last previous edition approved in 2007 as E 2544-07.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book
14、 of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American Society of Mechanical Engineers (ASME), ASMEInternational Headquarters, Three Park Ave., New York, NY 10016-5990, http:/www.asme.org.4Available from American National Standa
15、rds Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.5Available from National Institute of Standards and Technology (NIST), 100Bureau Dr., Stop 1070, Gaithersburg, MD 20899-1070, http:/www.nist.gov.e-Handbook available at http:/www.itl.nist.gov/div898/handbook/.1Cop
16、yright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.bias, ndifference between the average or expected value of adistribution and the true value.(NIST/SEMATECH e-Handbook)DISCUSSIONIn metrology, the difference between precision andaccuracy is
17、 that measures of precision are not affected by bias, whereasaccuracy measures degrade as bias increases.calibration, nset of operations that establish, under specifiedconditions, the relationship between values of quantitiesindicated by a measuring instrument or measuring system, orvalues represent
18、ed by a material measure or a referencematerial, and the corresponding values realized by standards.(VIM 6.11)DISCUSSION(1) The result of a calibration permits either the assignmentof values of measurands to the indications or the determinationof corrections with respect to indications.(2) A calibra
19、tion may also determine other metrologicalproperties such as the effect of influence quantities.(3) The result of a calibration may be recorded in adocument, sometimes called a calibration certificate or acalibration pensation, nthe process of determining systematic er-rors in an instrument and then
20、 applying these values in anerror model that seeks to eliminate or minimize measure-ment errors. (ASME B89.4.19)conventional true value (of a quantity), nvalue attributedto a particular quantity and accepted, sometimes by conven-tion, as having an uncertainty appropriate for a givenpurpose. (VIM 1.2
21、0)DISCUSSION(1) Examples: (1) at a given location, the value assigned tothe quantity realized by a reference standard may be taken asa conventional true value and (2) the CODATA (1986) recom-mended value for the Avogadro constant, NA: 6 022 136 7 31023mol-1.(2) Conventional true value is sometimes c
22、alled assignedvalue, best estimate of the value, conventional value, orreference value.(3) Frequently, a number of results of measurements of aquantity is used to establish a conventional true value.error (of measurement), nresult of a measurement minus atrue value of the measurand. (VIM 3.10)DISCUS
23、SION(1) Since a true value cannot be determined, in practice, aconventional true value is used (see true value and conven-tional true value).(2) When it is necessary to distinguish “error” from“relative error,” the former is sometimes called “absolute errorof measurement.” This should not be confuse
24、d with the“absolute value of error,” which is the modulus of error.indicating (measuring) instrument, nmeasuring instru-ment that displays an indication. (VIM 4.6)DISCUSSION(1) Examples include analog indicating voltmeter, digitalfrequency meter, and micrometer.(2) The display may be analog (continu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME25442007ASTANDARDTERMINOLOGYFORTHREEDIMENSIONAL3DIMAGINGSYSTEMS 三维 成象 系统 标准 术语 PDF

链接地址:http://www.mydoc123.com/p-531360.html