ASTM E2539-2008 Standard Practice for Multiangle Color Measurement of Interference Pigments《干涉颜料多角度颜色测量标准实施规程》.pdf
《ASTM E2539-2008 Standard Practice for Multiangle Color Measurement of Interference Pigments《干涉颜料多角度颜色测量标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2539-2008 Standard Practice for Multiangle Color Measurement of Interference Pigments《干涉颜料多角度颜色测量标准实施规程》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2539 08Standard Practice forMultiangle Color Measurement of Interference Pigments1This standard is issued under the fixed designation E 2539; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、 A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.INTRODUCTIONObjects that exhibit a change in color with different angles of illumination and view are said to be“gonioapparent.” The tristimulu
3、s colorimetric values of gonioapparent objects are derived using thespectral reflectance factors obtained from spectrometric measurements or colorimetric measurementsat various angles of illumination and detection. The tristimulus colorimetric values are computed usingthe spectral reflectance factor
4、s of the object, the CIE Standard Observer, and the spectral powerdistribution of the illuminant, as described in Practice E 308. This Practice, E 2539, specifies the colormeasurement of interference pigments at various illumination and detection angles.1. Scope1.1 This practice covers the instrumen
5、tal requirements andrequired parameters needed to make instrumental color mea-surements of thin film interference pigments. This practice isdesigned to encompass interference pigments used in architec-tural applications, automobiles, coatings, cosmetics, inks,packaging, paints, plastics, printing, s
6、ecurity, and other appli-cations.1.2 Characterization of the optical behavior of materialscolored with interference pigments requires measurement atmultiple angles of illumination and detection.1.3 Data taken utilizing this practice are quantitative and areappropriate for quality control of interfer
7、ence pigment color.1.4 The measurement results are usually expressed as re-flectance factors, tristimulus color values, or as CIE L*a*b*color coordinates and color difference.1.5 The totality of data taken may not be necessary forevaluating mixtures also containing non-interference pigments.The comm
8、ittee is investigating and evaluating the appropriate-ness of this practice for those materials. It is the responsibilityof the users to determine the applicability of this practice fortheir specific applications.1.6 Interference pigments are typically evaluated for colorand color appearance in a me
9、dium, such as paint or ink. Thegonioapparent effect depends strongly on the physical andchemical properties of the medium. Some of the propertiesaffecting color and color appearance include vehicle viscosity,thickness, transparency, and volume solids. As a general rule,for quality control purposes,
10、interference pigments are bestevaluated in a masstone product form. In some cases thisproduct form may be the final product form, or more typicallya qualified simulation of the intended product form (such as apaint drawdown) that in terms of color and appearancecorrelates to final product applicatio
11、n.1.7 This standard does not address the requirements forcharacterizing materials containing metal flake pigments. Mea-surements of the optical characteristics of materials containingmetal flake pigments are described in Practice E 2194.1.8 The values stated in SI units are to be regarded as thestan
12、dard. The values given in parentheses are for informationonly.1.9 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica
13、-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E 284 Terminology of AppearanceE 308 Practice for Computing the Colors of Objects byUsing the CIE SystemE 805 Practice for Identification of Instrumental Methods ofColor or Color-Difference Measurement of Mater
14、ialsE 1164 Practice for Obtaining Spectrometric Data forObject-Color EvaluationE 1345 Practice for Reducing the Effect of Variability ofColor Measurement by Use of Multiple Measurements1This practice is under the jurisdiction of ASTM Committee E12 on Color andAppearance and is the direct responsibil
15、ity of Subcommittee E12.12 on Gonioap-parent Color.Current edition approved Feb. 1, 2008. Published February 2008.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to th
16、e standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.E 1708 Practice for Electronic Interchange of Color andAppearance DataE 1767 Practice for Specifying the Geometries of Observa-tion
17、and Measurement to Characterize the Appearance ofMaterialsE 2194 Practice for Multiangle Color Measurement ofMetal Flake Pigmented MaterialsE 2480 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method with Multi-Valued Measurands2.2 ISCC Publications:3Technical
18、Report 20031 Guide to Material Standards andTheir Use in Color Measurement3. Terminology3.1 Terms and definitions in Terminology E 284, and Prac-tices E 1767 and E 2194 are applicable to this practice. SeeSection 5 of E 284 for “Specialized Terminology on Gonioap-parent Phenomena.”4. Summary of Prac
19、tice4.1 This practice describes the instrumental geometries,including abridged goniospectrometry, used to measure inter-ference pigments. Optical characterization requires color mea-surement at multiple illumination and multiple detection anglesspecified in this procedure. These sets of illumination
20、 anddetection angles are specified in the practice. Standardizationand verification of the instrument used to measure thesematerials are defined. The requirements for selection of speci-mens and measurement procedures are provided. The resultsare reported in terms of reflectance factors, CIE tristim
21、ulusvalues, and other color coordinate systems that define the colorof the object. Expected values of precision are presented.5. Significance and Use5.1 This practice is designed to provide color data obtainedfrom spectral reflectance factors at specific illumination anddetection angles for interfer
22、ence pigments. Information pre-sented in this test practice is based upon data taken on materialsexclusively pigmented with interference pigments.5.2 These data can be used for acceptance testing, designpurposes, research, manufacturing control, and quality control.5.3 Specimens must be statisticall
23、y representative of the enduse.5.4 Applicability of this practice for other materials, includ-ing combining interference pigments with absorbing and scat-tering pigments should be confirmed by the user.6. Environmental Conditions6.1 If the standard laboratory conditions listed belowchange during the
24、 test or from test to test by an appreciableamount, these conditions may reduce accuracy and precision ofthis test method. In some cases these effects may only beobserved during the performance of the test.6.2 Factors affecting test resultsThe following factors areknown to affect the test results.6.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME25392008STANDARDPRACTICEFORMULTIANGLECOLORMEASUREMENTOFINTERFERENCEPIGMENTS 干涉 颜料 角度 颜色 测量 标准 实施

链接地址:http://www.mydoc123.com/p-531348.html