ASTM E2303-2011 Standard Guide for Absorbed-Dose Mapping in Radiation Processing Facilities《辐射加工设施上吸收剂量标记的标准指南》.pdf
《ASTM E2303-2011 Standard Guide for Absorbed-Dose Mapping in Radiation Processing Facilities《辐射加工设施上吸收剂量标记的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2303-2011 Standard Guide for Absorbed-Dose Mapping in Radiation Processing Facilities《辐射加工设施上吸收剂量标记的标准指南》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2303 11An American National StandardStandard Guide forAbsorbed-Dose Mapping in Radiation Processing Facilities1This standard is issued under the fixed designation E2303; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、 the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This document provides guidance in determiningabsorbed-dose distributions (mapping) in products, material
3、sor substances irradiated in gamma, X-ray (bremsstrahlung) andelectron beam facilities.NOTE 1For irradiation of food and the radiation sterilization of healthcare products, other specific ISO and ISO/ASTM standards containingdose mapping requirements exist. For food irradiation, see ISO/ASTM51204, P
4、ractice for Dosimetry in Gamma Irradiation Facilities for FoodProcessing and ISO/ASTM 51431, Practice for Dosimetry in ElectronBeam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food Pro-cessing. For the radiation sterilization of health care products, seeISO 11137-1, Sterilization of Health
5、 Care Products Radiation Part 1:Requirements for Development, Validation and Routine Control of aSterilization Process for Medical Devices. In those areas covered byISO 11137-1, that standard takes precedence. ISO/ASTM 51608, Practicefor Dosimetry in an X-ray (Bremsstrahlung) Facility for RadiationP
6、rocessing, ISO/ASTM 51649, Practice for Dosimetry in an ElectronBeam Facility for Radiation Processing at Energies between 300 keV and25 Mev, ISO/ASTM 51702, Practice for Dosimetry in a Gamma Irradia-tion Facility for Radiation Processing, and ISO/ASTM 51818, Practice forDosimetry in an Electron Bea
7、m Facility for Radiation Processing atEnergies Between 80 and 300 KeV also contain dose mapping require-ments.1.2 This guide is one of a set of standards that providesrecommendations for properly implementing dosimetry inradiation processing. it is intended to be read in conjunctionwith ASTM Practic
8、e E2628.1.3 Methods of analyzing the dose map data are described.Examples are provided of statistical methods that may be usedto analyze dose map data.1.4 Dose mapping for bulk flow processing and fluidstreams is not discussed.1.5 Dosimetry is only one component of a total qualityprogram for an irra
9、diation facility. Other controls besidesdosimetry may be required for specific applications such asmedical device sterilization and food preservation.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this
10、standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory requirements prior to use.2. Referenced Documents2.1 ASTM Standards:2E170 Terminology Relating to Radiation Measurements andDosimetryE178 Practice for Dealing With Outlying ObservationsE2232
11、 Guide for Selection and Use of Mathematical Meth-ods for CalculatingAbsorbed Dose in Radiation ProcessingApplicationsE2628 Practice for Dosimetry in Radiation Processing2.2 ISO/ASTM Standards:2ISO/ASTM 51204 Practice for Dosimetry in Gamma Irra-diation Facilities for Food ProcessingISO/ASTM 51261 G
12、uide for Selection and Calibration ofDosimetry Systems for Radiation ProcessingISO/ASTM 51431 Practice for Dosimetry in Electron Beamand X-Ray (Bremsstrahlung) Irradiation Facilities forFood ProcessingISO/ASTM 51608 Practice for Dosimetry in an X-ray(Bremsstrahlung) Facility for Radiation Processing
13、ISO/ASTM 51649 Practice for Dosimetry in an ElectronBeam Facility for Radiation Processing at Energies be-tween 300 keV and 25 MeVISO/ASTM 51702 Practice for Dosimetry in a GammaIrradiation Facility for Radiation ProcessingISO/ASTM 51707 Guide for Estimating Uncertainties inDosimetry for Radiation P
14、rocessingISO/ASTM 51818 Practice for Dosimetry in an ElectronBeam Facility for Radiation Processing at Energies be-tween 80 and 300 keV2.3 International Commission on Radiation Units andMeasurements Reports:3ICRU Report 60 Fundamental Quantities and Units forIonizing Radiation1This guide is under th
15、e jurisdiction of ASTM Committee E10 on NuclearTechnology and Applications and is the direct responsibility of SubcommitteeE10.01 on Radiation Processing: Dosimetry and Applications.Current edition approved July 1, 2011. Published August 2011. Originallyapproved in 2003. Last previous edition approv
16、ed in 2003 as E2303-03. DOI:10.1520/E2303-11.2For referenced ASTM and ISO/ASTM standards, visit the ASTM website,www.astm.org, or contact ASTM Customer Service at serviceastm.org. ForAnnual Book of ASTM Standards volume information, refer to the standardsDocument Summary page on the ASTM website.3Av
17、ailable from International Commission on Radiation Units and Measure-ments, 7910 Woodmont Ave., Suite 800, Bethesda, MD 20814.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.ICRU Report 80 Dosimetry Systemes for Use in RadiationProce
18、ssing2.4 International Organization for Standardization:4ISO 11137-1 Sterilization of health care products Radia-tion Part 1: Requirements for development, validation,and routine control of a sterilization process for medicaldevicesGUM Guide to the Expression of Uncertainty in Measure-ment, 1995, IS
19、BN 92-6710188-9VIM International Vocabulary of Basic and General Termsin Metrology3. Terminology3.1 Definitions:3.1.1 absorbed-dose mappingmeasurement of absorbeddose within an irradiated product to produce a one-, two- orthree-dimensional distribution of absorbed dose, thus renderinga map of absorb
20、ed-dose values.3.1.1.1 DiscussionFor a process load, such a dose map isobtained using dosimeters placed at specified locations withinthe process load.3.1.2 calibration curve (VIM:2008)expression of the re-lation between indication and corresponding measured quantityvalue.3.1.2.1 DiscussionIn radiati
21、on processing standards, theterm “dosimeter response” is generally used for “indication.”3.1.3 dose map, dose mappingsee absorbed-dose map-ping.3.1.4 dose uniformity ratioratio of the maximum to theminimum absorbed dose within the irradiated product.3.1.4.1 DiscussionThe concept is also referred to
22、as themax/min dose ratio. Product generally refers to the “processload.”3.1.5 dose zonea volume or discrete point(s) within aprocess load that receives the same absorbed dose within thestatistical uncertainty of the irradiation process and absorbed-dose measurement(s).3.1.6 installation qualificatio
23、n (IQ)process of obtainingand documenting evidence that equipment has been providedand installed in accordance with its specification.3.1.7 irradiation containerholder in which process load istransported through the irradiator.3.1.7.1 Discussion“Irradiation container” is often referredto simply as “
24、container” and can be a carrier, cart, try, productcarton, pallet, product package or other holder.3.1.8 operational qualification (OQ)process of obtainingand documenting evidence that installed equipment operateswithin predetermined limits when used in accordance with itsoperational procedures.3.1.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME23032011STANDARDGUIDEFORABSORBEDDOSEMAPPINGINRADIATIONPROCESSINGFACILITIES 辐射 加工 设施 吸收剂量 标记 标准 指南

链接地址:http://www.mydoc123.com/p-530823.html