1、Designation: E1109 86 (Reapproved 2009)Standard Test Method forDetermining the Bulk Density of Solid Waste Fractions1This standard is issued under the fixed designation E1109; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the yea
2、r of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method determines the bulk density of variousfractions from the resource recovery processing of municip
3、alsolid waste. It is intended as a means of characterizing suchfractions and for providing data useful to designers of solidwaste processing plants.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this st
4、andard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific precau-tionary information is given in Section 7.2. Referenced Documents2.1 ASTM Standards:2C702 Practice for Reducing Samples of Aggregate to Test-ing SizeD
5、75 Practice for Sampling AggregatesE689 Reference Radiographs for Ductile Iron CastingsE1107 Test Method for Measuring the Throughput ofResource-Recovery Unit Operations3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 bulk densitythe mass per unit volume of particulatematter. B
6、ulk density is not an absolute material property as isthe density of individual particles of a material. The bulkdensity depends on the size of the container and how thematerial is loaded into the container. For example, the bulkdensity of material placed loosely in a container will be lessthan that
7、 of material tamped into a container. Also, somematerials placed loosely in a container will settle with time dueto its own weight; thus, its bulk density will increase.4. Summary of Test Method4.1 A sample of a solid waste stream is tamped in a cubicalcontainer of known volume and then weighed. Bul
8、k density iscalculated from the weight of the contents and volume of thecontainer.5. Significance and Use5.1 This test method describes a physical property of solidwaste in processing facilities; a property that characterizes thesolid waste streams and hence the operation of resourcerecovery separat
9、ors and processors.5.2 The bulk density is an important property for the designof materials handling equipment, separators, and processors.6. Apparatus6.1 BalanceA balance or scale accurate within 0.1% ofthe test load at any point within the range of use. The range ofuse shall be considered to exten
10、d from the weight of themeasure empty to the weight of the measure plus its contents.6.2 Cubical Measure, with internal dimensions approxi-mately 60 by 60 by 60 cm (24 by 24 by 24 in.) provided withhandles. The interior surfaces of the measure shall be nonab-sorbent to moisture.NOTE 1A satisfactory
11、weigh box has been constructed of34 in. (1.9cm) exterior grade plywood with the finished surface on the inside.Reinforcing strips, approximately 5 cm (2 in.) wide and 1.3 cm (12 in.)thick were fastened to the outside walls; two of them in a way to providehandles.6.3 Larger cubical weigh boxes shall
12、be used as necessary toaccommodate large particles of material. No particle largerthan two-thirds the length, height, or width of the weigh boxshall be put into the weigh box in determining the bulk density.7. Precautions7.1 This procedure calls for the handling of solid waste andits processed fract
13、ions. Because the origin of all the materialsis generally unknown, workers must use proper safety precau-tions when handling samples. Workers shall wear gloves andsafety glasses. When appropriate, dust masks shall be worn.Workers must be cautioned to wash their hands thoroughlybefore eating or smoki
14、ng.1This test method is under the jurisdiction of ASTM Committee D34 on WasteManagement and is the direct responsibility of Subcommittee D34.03 on Treatment,Recovery and Reuse.Current edition approved Sept. 1, 2009. Published November 2009. Originallyapproved in 1986. Last previous edition approved
15、in 2004 as E110986(2004). DOI:10.1520/E1109-86R09.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME110919862009STANDARDTESTMETHODFORDETERMININGTHEBULKDENSITYOFSOLIDWASTEFRACTIONS 测量 固体 废料 碎片 密度 标准

链接地址:http://www.mydoc123.com/p-527926.html