ASTM D7598-2009e1 8750 Standard Test Method for Determination of Thiodiglycol in Water by Single Reaction Monitoring Liquid Chromatography Tandem Mass Spectrometry《用单反应检测液相色谱 串联质谱法.pdf
《ASTM D7598-2009e1 8750 Standard Test Method for Determination of Thiodiglycol in Water by Single Reaction Monitoring Liquid Chromatography Tandem Mass Spectrometry《用单反应检测液相色谱 串联质谱法.pdf》由会员分享,可在线阅读,更多相关《ASTM D7598-2009e1 8750 Standard Test Method for Determination of Thiodiglycol in Water by Single Reaction Monitoring Liquid Chromatography Tandem Mass Spectrometry《用单反应检测液相色谱 串联质谱法.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7598 091Standard Test Method forDetermination of Thiodiglycol in Water by Single ReactionMonitoring Liquid Chromatography/Tandem MassSpectrometry1This standard is issued under the fixed designation D7598; the number immediately following the designation indicates the year oforiginal ad
2、option or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEThis Test Method was changed editorially in 2012.1. Scope1.1 This procedure c
3、overs the determination of thiodiglycol(TDG) in surface water by direct injection using liquidchromatography (LC) and detected with tandem mass spec-trometry (MS/MS). TDG is qualitatively and quantitativelydetermined by this method. This method adheres to singlereaction monitoring (SRM) mass spectro
4、metry.1.2 This test method has been developed by US EPARegion5 Chicago Regional Laboratory (CRL).1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 The Detection Verification Level (DVL) and ReportingRange for TDG are liste
5、d in Table 1.1.4.1 The DVL is required to be at a concentration at least3 times below the reporting limit (RL) and have a signal/noiseratio greater than 3:1. Fig. 1 displays the signal/noise ratio atthe DVL.1.4.2 The RL is the concentration of the level 1 calibrationstandard as shown in Table 2. The
6、 reporting limit for thismethod is 100 g/L.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulato
7、ry limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1129 Terminology Relating to WaterD1193 Specification for Reagent WaterD2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee D19 on WaterD3856 Guide for Management Systems in LaboratoriesE
8、ngaged in Analysis of WaterD3694 Practices for Preparation of Sample Containers andfor Preservation of Organic ConstituentsD5847 Practice for Writing Quality Control Specificationsfor Standard Test Methods for Water AnalysisE2554 Practice for Estimating and Monitoring the Uncer-tainty of Test Result
9、s of a Test Method in a SingleLaboratory Using a Control Sample Program2.2 Other Documents:EPApublication SW-846 Test Methods for Evaluating SolidWaste, Physical/Chemical Methods33. Terminology3.1 Definitions:3.1.1 detection verification level (DVL), na concentrationthat has a signal/noise ratio gre
10、ater than 3:1 and is at least 3times below the reporting limit (RL).3.1.2 reporting limit (RL), nthe concentration of thelowest-level calibration standard used for quantification.3.2 Abbreviations:3.2.1 NDnon-detect4. Summary of Test Methods4.1 This is a performance based method and modificationsare
11、 allowed to improve performance.4.2 For thiodiglycol analysis, samples are shipped to the labbetween 0C and 6C and analyzed within 7 days of collection.In the lab, the samples are spiked with surrogate, filtered using1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is th
12、e direct responsibility of Subcommittee D19.06 on Methods forAnalysis forOrganic Substances in Water.Current edition approved Dec. 1, 2009. Published February 2012. DOI: 10.1520/D7598-09E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at servi
13、ceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from National Technical Information Service (NTIS), U.S. Depart-ment of Commerce, 5285 Port Royal Road, Springfield, VA, 22161 or at http:/www.epa.gov/epawaste/
14、hazard/testmethods/index.htm.TABLE 1 Detection Verification Level and Reporting RangeAnalyte DVL (g/L) Reporting Range (g/L)Thiodiglycol 20 10010 0001Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.a syringe driven Millex HV PVDF filt
15、er unit and analyzeddirectly by LC/MS/MS.4.3 Thiodiglycol and 3,3-thiodipropanol (surrogate) areidentified by retention time and one SRM transition. The targetanalyte and surrogate are quantitated using the SRM transitionsutilizing an external calibration. The final report issued foreach sample list
16、s the concentration of TDG and the 3,3-thiodipropanol surrogate recovery.5. Significance and Use5.1 Thiodiglycol is a Schedule 2 compound under theChemical Weapons Convention (CWC). Schedule 2 chemicalsinclude those that are precursors to chemical weapons, chemi-cal weapons agents or have a number o
17、f other commercialuses. They are used as ingredients to produce insecticides,herbicides, lubricants, and some pharmaceutical products.Schedule 2 chemicals can be found in applications unrelated tochemical weapons. Thiodiglycol is both a mustard gas precur-sor and degradant as well as an ingredient i
18、n water-based inks,ballpoint pen inks, dyes and some pesticides.45.2 This method has been investigated for use with reagentand surface water.6. Interferences6.1 Method interferences may be caused by contaminants insolvents, reagents, glassware and other apparatus producingdiscrete artifacts or eleva
19、ted baselines. All of these materialsare demonstrated to be free from interferences by analyzinglaboratory reagent blanks under the same conditions assamples.6.2 All glassware is washed in hot water with a detergent,rinsed in hot water followed by distilled water. The glasswareis then dried and heat
20、ed in an oven at 250C for 15 to 30minutes. All glassware is subsequently cleaned with acetone,then methanol.6.3 All reagents and solvents should be pesticide residuepurity or higher to minimize interference problems.6.4 Matrix interferences may be caused by contaminantsthat are co-extracted from the
21、 sample. The extent of matrixinterferences can vary considerably from sample source de-pending on variations of the sample matrix.7. Apparatus7.1 LC/MS/MS System4Additional information about CWC and thiodiglycol is available on the Internetat http:/www.opcw.org (2009)FIG. 1 Example SRM Chromatograms
22、 Signal/Noise at Detection Verification LevelTABLE 2 Concentrations of Calibration Standards (PPB)Analyte/Surrogate LV 1 LV 2 LV 3 LV 4 LV 5 LV 6 LV 7Thiodiglycol 100 250 500 1000 2500 5000 10 0003,3-Thiodipropanol 100 250 500 1000 2500 5000 10 000D7598 09127.1.1 Liquid Chromatography (LC) SystemA c
23、ompleteLC system is needed in order to analyze samples.5A systemthat is capable of performing at the flows, pressures, controlledtemperatures, sample volumes and requirements of the stan-dard may be used.7.1.2 Analytical Column-SIELCPrimesep SB 5 m, 100 particle, 150 mm 3 2.1 mm or equivalent.7.1.3
24、Tandem Mass Spectrometer (MS/MS) SystemAMS/MS system capable of MRM analysis.6A system that iscapable of performing at the requirements in this standard maybe used.7.2 Filtration Device7.2.1 Hypodermic syringeAlock tip glass syringe capableof holding a Millex HV Syringe Driven Filter Unit PVDF 0.45m
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD75982009E18750STANDARDTESTMETHODFORDETERMINATIONOFTHIODIGLYCOLINWATERBYSINGLEREACTIONMONITORINGLIQUIDCHROMATOGRAPHYTANDEMMASSSPECTROMETRY

链接地址:http://www.mydoc123.com/p-525918.html