ASTM D7338-2014 7205 Standard Guide for Assessment Of Fungal Growth in Buildings《建筑物中真菌生长评估的标准指南》.pdf
《ASTM D7338-2014 7205 Standard Guide for Assessment Of Fungal Growth in Buildings《建筑物中真菌生长评估的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7338-2014 7205 Standard Guide for Assessment Of Fungal Growth in Buildings《建筑物中真菌生长评估的标准指南》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7338 14Standard Guide forAssessment Of Fungal Growth in Buildings1This standard is issued under the fixed designation D7338; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in paren
2、theses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide provides a compendium of information and amenu of options for assessment of fungal growth in buildings,but does not recommend a specific co
3、urse of action. Due to thewide variety of fungal problems affecting buildings and theiroccupants, and the wide variety of buildings, it is not possibleto describe a set of uniform steps that will always be performedduring an assessment (that is, a standard practice); therefore theuser of this guide
4、must decide which steps are appropriate fora given situation or building.1.2 This guide is specific to fungal growth, which is onlyone potential problem in a building environment. It may be partof, but is not intended to take the place of, a comprehensiveindoor air quality investigation.1.3 This gui
5、de describes minimum steps and procedures forcollecting background information on a building in question,procedures for evaluating the potential for moisture infiltrationor collection, procedures for inspection for suspect fungalgrowth, and procedures beyond the scope of a basic survey thatmay be us
6、eful for specific problems.1.4 Assessments for fungal growth may be useful whereverfungal growth is suspected, excess moisture has been presentor when there are concerns regarding potential fungal growth.1.5 Periodic fungal assessment in buildings may be acomponent of preventative maintenance progra
7、ms.1.6 This guide is applicable to buildings including residen-tial (for example, single or multi-family), institutional (forexample, schools, hospitals), government, public assembly,commercial (for example, office, retail), and industrial facili-ties.1.7 Recommendations for developing a sampling st
8、rategy ormethods for the collection and analysis of fungal samples arebeyond the scope of this guide. For recommendations fordeveloping a sampling strategy, see Ref (1)2, Chapter 10.1.8 Recommendations for remediation of fungal growth arebeyond the scope of this guide.1.9 This guide is not intended
9、to supersede any governmentregulations governing the assessment of fungal growth inbuildings.1.10 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health pra
10、ctices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3C755 Practice for Selection of Water Vapor Retarders forThermal InsulationC1699 Test Method for Moisture Retention Curves of Po-rous Building Materials Using Pressure PlatesD653
11、Terminology Relating to Soil, Rock, and ContainedFluidsD4442 Test Methods for Direct Moisture Content Measure-ment of Wood and Wood-Base MaterialsE331 Test Method for Water Penetration of ExteriorWindows, Skylights, Doors, and Curtain Walls by Uni-form Static Air Pressure DifferenceE547 Test Method
12、for Water Penetration of ExteriorWindows, Skylights, Doors, and Curtain Walls by CyclicStatic Air Pressure DifferenceE631 Terminology of Building ConstructionsE1105 Test Method for Field Determination of Water Pen-etration of Installed Exterior Windows, Skylights, Doors,and Curtain Walls, by Uniform
13、 or Cyclic Static AirPressure DifferenceE1186 Practices for Air Leakage Site Detection in BuildingEnvelopes and Air Barrier SystemsE1356 Test Method for Assignment of the Glass TransitionTemperatures by Differential Scanning CalorimetryE2128 Guide for Evaluating Water Leakage of BuildingWalls1This g
14、uide is under the jurisdiction of ASTM Committee D22 on Air Qualityand is the direct responsibility of Subcommittee D22.08 on Sampling and Analysisof Mold.Current edition approved June 1, 2014. Published July 2014. Originally approvedin 2010. Last previous edition approved in 2010 as D7338 10. DOI:1
15、0.1520/D7338-14.2The boldface numbers in parentheses refer to a list of references at the end ofthis standard.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the st
16、andards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1E2270 Practice for Periodic Inspection of Building Facadesfor Unsafe Conditions2.2 Non-ASTM Standards:ANSI/GEI Standard MMS1001 Mold and
17、Moisture Man-agement Standard for New Construction3. Terminology3.1 Definitions:3.1.1 building envelope, nthe outer elements of abuilding, both above and below ground, which divide theexternal from the internal environments. Commonly includedare exterior walls, windows, doors, roofs and subfloors. E
18、6313.1.2 bulk sample, npiece or quantity of bulk material thathas been selected by some sampling process. D6533.1.3 capillary action, n(or capillary migration), of water,movement of water induced by the force of molecular attrac-tion (surface tension) between the water and the material itcontacts. E
19、6313.1.4 condensation, nthe process of converting a materialin the gaseous phase to a liquid by decreasing temperature orby increasing pressure, or both. E13563.1.5 exposure, ncontact with a chemical, biological,physical, or other agent over a specified time period. E13563.1.6 moisture content, nmas
20、s of water retained in thespecimen divided by the dry mass of the specimen. C16993.1.7 soot, nagglomerations of particles of carbon impreg-nated with tar, formed in the incomplete combustion ofcarbonaceous material. E13563.1.8 vapor retarder, na material or system that ad-equately impedes the transm
21、ission of water vapor underspecified conditions. E6313.2 Definitions of Terms Specific to This Standard:3.2.1 boroscope, ndevice for internal inspection of diffi-cult access locations such as wall cavities. Its long narrow tubecontains a telescope system with a number of relay lenses.Light is provid
22、ed via the optical path or fiber bundles.3.2.2 effloresce, vprocess by which water leaches solublesalts out of concrete or mortar for surface deposit. Alsoefflorescence, n, the name for these deposits.3.2.3 enzyme activity, nmeasure of the quantity of activeenzyme present. Enzyme activity is essenti
23、al to metabolism.Specifically, beta-N-acetylhexosaminidase (NAHA) is an en-zyme present in all filamentous fungi, the measurement ofwhich has been shown to be directly proportional to the amountof fungal biomass (see (2, 3).3.2.4 fungus (s), fungi (pl.), neukaryotic, heterotrophic,absorptive organis
24、ms that usually develop a rather diffuse,branched, tubular body (that is, network of hyphae) and usuallyreproduce by means of spores (4). The terms mold andmildew are frequently used by laypersons when referring tovarious fungal colonization.3.2.5 fungal spore, ngeneral term for a reproductivestruct
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD733820147205STANDARDGUIDEFORASSESSMENTOFFUNGALGROWTHINBUILDINGS 建筑物 真菌 生长 评估 标准 指南 PDF

链接地址:http://www.mydoc123.com/p-525207.html