ASTM D7240-2006 Standard Practice for Leak Location using Geomembranes with an Insulating Layer in Intimate Contact with a Conductive Layer via Electrical Capacitance Technique (Co.pdf
《ASTM D7240-2006 Standard Practice for Leak Location using Geomembranes with an Insulating Layer in Intimate Contact with a Conductive Layer via Electrical Capacitance Technique (Co.pdf》由会员分享,可在线阅读,更多相关《ASTM D7240-2006 Standard Practice for Leak Location using Geomembranes with an Insulating Layer in Intimate Contact with a Conductive Layer via Electrical Capacitance Technique (Co.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 7240 06Standard Practice forLeak Location using Geomembranes with an InsulatingLayer in Intimate Contact with a Conductive Layer viaElectrical Capacitance Technique (ConductiveGeomembrane Spark Test)1This standard is issued under the fixed designation D 7240; the number immediately fo
2、llowing the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This standard
3、 is a performance-based practice for usingthe spark test to electrically locate leaks in exposed geomem-branes with an insulating layer that are in intimate contact witha conductive layer. For clarity, this document uses the termleak to mean holes, punctures, tears, cuts, cracks and similarbreaches
4、over the partial or entire area of an installed geomem-brane (as defined in 3.2.3).1.2 This test method can be used on exposed geomembranesinstalled in basins, ponds, tanks, ore and waste pads, landfillcells, landfill caps, and other containment facilities. Thisstandard is applicable for geomembrane
5、s in direct and intimatecontact with a conductive surface or with a conductive layerintegrally included.1.3 SAFETY WARNING: The electrical methods used forgeomembrane leak location use high voltage, low currentpower supplies, resulting in the potential for electrical shock.The electrical methods use
6、d for geomembrane leak locationshould be attempted by only qualified and experienced person-nel. Appropriate safety measures must be taken to protect theleak location operators as well as other people at the site.1.4 This standard does not purport to address all of thesafety and liability concerns,
7、if any, associated with its use. Itis the responsibility of the user of this standard to establishappropriate safety and health practices and determine theapplicability of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 4439 Terminology for GeosyntheticsD 6747 Guide
8、for Selection of Techniques for ElectricalDetection of Potential Leak Paths in Geomembranes3. Terminology3.1 Definition of terms applying to this test method appearin Terminology D 4439.3.2 Definitions:3.2.1 electrical leak location, na method which useselectrical current or electrical potential to
9、detect and locateleaks.3.2.2 geomembrane, nan essentially impermeable mem-brane used with foundation, soil, rock, earth or any othergeotechnical engineering related material as an integral part ofa man made project, structure, or system.3.2.3 leak, nFor the purposes of this document, a leak isany un
10、intended opening, perforation, breach, slit, tear, punctureor crack. Significant amounts of liquids or solids may or maynot flow through a leak. Scratches, gouges, dents, or otheraberrations that do not completely penetrate the geomembraneare not considered to be leaks.Leaks detected during surveys
11、have been grouped into threecategories: Holes round shaped voids with downward or upwardprotruding rims Tears linear or circular voids with irregular edge borders Linear cuts linear voids with neat close edges3.2.4 intimate contact, nfor the purposes of this docu-ment, intimate contact is when a con
12、ductive layer is in directcontact with the insulating geomembrane, and there are nogaps between the two layers to prohibit the flow of current.3.2.5 leak detection sensitivity, nThe smallest size leakthat the leak location equipment and survey methodology arecapable of detecting under a given set of
13、 conditions. The leakdetection sensitivity specification is usually stated as a diam-eter of the smallest leak that can be reliably detected.3.2.6 wand, nfor the purposes of this document, any rodthat has a conductive brush that is attached to a power sourceto initiate the spark test.1This practice
14、is under the jurisdiction of ASTM Committee D35 on Geosyn-thetics and is the direct responsibility of Subcommittee D35.10 on Geomembranes.Current edition approved Jan. 1, 2006. Published February 2006.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Servi
15、ce at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4. Summary of Practice4.1 The principle of th
16、is electrical leak location method is touse a high voltage pulsed power supply to charge a capacitorformed by the underlying conductive layer, the non-conductivelayer of the geomembrane and a coupling pad. The area is thenswept with a test wand to locate points where the capacitordischarges through
17、a leak. Once the system senses the dis-charge current, it is converted into an audible alarm.4.2 General Principles4.2.1 Fig. 1 shows a wiring diagram of the coupling pad,power supply and test wand for the electrical leak locationmethod of a geomembrane with a lower conductive layer. Onceall necessa
18、ry connections are made, the pad is placed on theupper surface of the geomembrane. The nonconductive (insu-lating layer(s) of the geomembrane act as a dielectric in acapacitor which stores electrical potential across the geomem-brane.FIG. 1 Wiring Diagram of the Equipment Required for Spark Testing
19、Geomembrane in Intimate Contact With a Conductive Surface.D72400624.2.2 A grid, test lanes or other acceptable system should beused to ensure that the entire area is tested with the test wand.4.2.3 Either a hand held wand or a larger wand mounted toan all terrain vehicle may be used. Generally a han
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD72402006STANDARDPRACTICEFORLEAKLOCATIONUSINGGEOMEMBRANESWITHANINSULATINGLAYERININTIMATECONTACTWITHACONDUCTIVELAYERVIAELECTRICALCAPACITANCETECHNIQUECOPDF

链接地址:http://www.mydoc123.com/p-524916.html