《ASTM D6332-2012 6250 Standard Guide for Testing Systems for Measuring Dynamic Responses of Carbon Monoxide Detectors to Gases and Vapors《一氧化碳测量器对气体和蒸气测量的动态响应的试验系统的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6332-2012 6250 Standard Guide for Testing Systems for Measuring Dynamic Responses of Carbon Monoxide Detectors to Gases and Vapors《一氧化碳测量器对气体和蒸气测量的动态响应的试验系统的标准指南》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6332 12Standard Guide forTesting Systems for Measuring Dynamic Responses ofCarbon Monoxide Detectors to Gases and Vapors1This standard is issued under the fixed designation D6332; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、 revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide describes testing systems used for measuringresponses of carbon monoxide (CO) alarms
3、 or detectorssubjected to gases, vapors, and their mixtures.1.2 The systems are used to evaluate responses of COdetectors to various CO concentrations, to verify that thedetectors alarm at certain specified CO concentrations, and toverify that CO detectors do not alarm at certain other specifiedCO c
4、oncentrations.1.3 The systems are used for evaluating CO detector re-sponses to gases and vapors that may interfere with the abilityof detectors to respond to CO.1.4 Major components of such a testing system include achamber, clean air supply module, humidification module, gasand vapor delivery modu
5、le, and verification and control instru-mentation.1.5 For each component, this guide provides a comparisonof different approaches and discusses their advantages anddisadvantages.1.6 The guide also presents recommendations for a mini-mum configuration of a testing system.1.7 UnitsThe values stated in
6、 SI units are to be regardedas standard. No other units of measurement are included in thisstandard.1.8 This guide does not purport to address all of the safetyconcerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety andhealth pr
7、actices and determine the applicability of regulatorylimitations prior to use. For more specific safety precautionaryinformation, see 6.2.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterD1356 Terminology Relating to Sampling and Analysis ofAtmospheresD1945 Test Method
8、 for Analysis of Natural Gas by GasChromatographyD3162 Test Method for Carbon Monoxide in the Atmo-sphere (Continuous Measurement by Nondispersive Infra-red Spectrometry)D3195 Practice for Rotameter CalibrationD3249 Practice for General Ambient Air Analyzer Proce-duresD3687 Practice for Analysis of
9、Organic Compound VaporsCollected by the Activated Charcoal Tube AdsorptionMethod2.2 Other Standards:UL 2034 Single and Multiple Station Carbon MonoxideAlarms3CFR 1910.1450 Occupational Exposure to HazardousChemicals in Laboratories43. Terminology3.1 Definitions:For definitions of terms used in this
10、guide, refer to Termi-nology D1356.3.2 Definitions of Terms Specific to This Standard:3.2.1 air change ratethe volume of clean, humidified airplus contaminants that enters the chamber in 1 h, divided bythe internal volume of the chamber, expressed as air changesper hour (h1).3.2.2 chamberan enclosed
11、 test volume composed ofchemically inert materials supplied with a mixture of air, gases,or vapors, or combination thereof, having known composi-tions.3.2.3 CO alarm/detectoran alarm device consisting of anassembly of electrical and mechanical components with chemi-cal, electrochemical, solid-state
12、electronic, or other types ofsensors to detect the presence of CO gas in specified ranges ofconcentrations.1This guide is under the jurisdiction of ASTM Committee D22 on Air Qualityand is the direct responsibility of Subcommittee D22.05 on Indoor Air.Current edition approved April 1, 2012. Published
13、 May 2012. Originallyapproved in 1998. Last previous edition approved in 1999 as D6332 - 99 (2005).DOI: 10.1520/D6332-12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refe
14、r to the standards Document Summary page onthe ASTM website.3Available from Underwriters Laboratories (UL), 2600 N.W. Lake Rd., Camas,WA 98607-8542, http:/.4Available from U.S. Government Printing Office Superintendent of Documents,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http:/
15、www.access.gpo.gov.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.4 sensorthe component included in the CO alarm/detector that senses CO gas.4. Summary of Guide4.1 This guide describes components of systems for testingCO detecto
16、rs with mixtures of air and CO at different concen-trations of CO. The systems are also used for evaluating theresponses of CO detectors to mixtures of air and various gasesor vapors, or both. Such systems require clean air with apreselected level of relative humidity supplied to an environ-mental c
17、hamber. Gases and vapors are introduced in the cleanair supply or placed directly in the chamber to achieve desiredchamber concentration. The components of such systemsinclude devices or modules for supplying pure air, humidifyingair, supplying gases or vapors, or both, to be tested, referenceinstru
18、ments for verifying concentrations of gases and vapors,and a chamber for placing and exposing CO detectors. Theguide describes various options for each component: chamber(Section 6), clean air supply module (Section 7), humidifica-tion module (Section 8), gas/vapor delivery module (Section9), and ve
19、rification and control module (Section 10). The guidefurther provides recommendations on a minimum configura-tion for the testing system (Section 11) and reporting results(Section 12).5. Significance and Use5.1 This guide provides information on testing systems andtheir components used for measuring
20、 responses of CO alarmsor detectors subjected to gases, vapors, and their mixtures.Components of a testing system include a chamber, clean airsupply module, humidification module, gas and vapor deliverymodule, and verification and control instrumentation.5.2 The CO detector is tested by sequential e
21、xposure to COand interference gases at the specified challenge concentra-tions. A properly functioning alarm/detector will sound uponsufficient exposure to CO but will not sound upon any exposureto interference gases consistent with applicable standards (forexample, IAS 6-96 (1)5, UL 2034).6. Chambe
22、r6.1 Types of ChamberThere are two types of chambersstatic and dynamic. In a static chamber, air and knownquantities of gases are introduced and then the chamber issealed. In a dynamic chamber, a characterized air-gas mixtureis continually introduced at a rate sufficient to maintain targetconcentrat
23、ions.6.2 HazardsIn a dynamic chamber, the air exiting cham-ber will contain CO and interference gases or vapors that maybe toxic. To avoid undue exposures of toxic gases and vaporsto occupants of the laboratory (where the chamber is located),the chamber should be properly vented to outside with anap
24、propriate stack. For a static chamber, exposures to test gasesshould be avoided in operating (for example, opening) thechamber.6.3 Size of the ChamberThe chamber size can be large(that is, room-size) or small and depends on the number ofdetectors to be tested. Detectors should be placed on a wirerac
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD633220126250STANDARDGUIDEFORTESTINGSYSTEMSFORMEASURINGDYNAMICRESPONSESOFCARBONMONOXIDEDETECTORSTOGASESANDVAPORS

链接地址:http://www.mydoc123.com/p-522195.html