ASTM D6332-1999(2005) Standard Guide for Testing Systems for Measuring Dynamic Responses of Carbon Monoxide Detectors to Gases and Vapors《测量一氧化碳测量器对气体和蒸气的动态反应的试验系统的标准指南》.pdf
《ASTM D6332-1999(2005) Standard Guide for Testing Systems for Measuring Dynamic Responses of Carbon Monoxide Detectors to Gases and Vapors《测量一氧化碳测量器对气体和蒸气的动态反应的试验系统的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6332-1999(2005) Standard Guide for Testing Systems for Measuring Dynamic Responses of Carbon Monoxide Detectors to Gases and Vapors《测量一氧化碳测量器对气体和蒸气的动态反应的试验系统的标准指南》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6332 99 (Reapproved 2005)Standard Guide forTesting Systems for Measuring Dynamic Responses ofCarbon Monoxide Detectors to Gases and Vapors1This standard is issued under the fixed designation D 6332; the number immediately following the designation indicates the year oforiginal adoptio
2、n or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide describes testing systems used for measuringresponses of carbon
3、 monoxide (CO) alarms or detectorssubjected to gases, vapors, and their mixtures.1.2 The systems are used to evaluate responses of COdetectors to various CO concentrations, to verify that thedetectors alarm at certain specified CO concentrations, and toverify that CO detectors do not alarm at certai
4、n other specifiedCO concentrations.1.3 The systems are used for evaluating CO detector re-sponses to gases and vapors that may interfere with the abilityof detectors to respond to CO.1.4 Major components of such a testing system include achamber, clean air supply module, humidification module, gasan
5、d vapor delivery module, and verification and control instru-mentation.1.5 For each component, this guide provides a comparisonof different approaches and discusses their advantages anddisadvantages.1.6 The guide also presents recommendations for a mini-mum configuration of a testing system.1.7 This
6、 guide does not purport to address all of the safetyconcerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety andhealth practices and determine the applicability of regulatorylimitations prior to use. For more specific safety prec
7、autionaryinformation, see 6.2.2. Referenced Documents2.1 ASTM Standards:2D 1193 Specification For Reagent WaterD 1356 Terminology Relating to Sampling and Analysis ofAtmospheresD 1945 Test Method for Analysis of Natural Gas by GasChromatographyD 3162 Test Method for Carbon Monoxide in the Atmo-spher
8、e (Continuous Measurement by Nondispersive Infra-red Spectrometry)D 3195 Practice for Rotameter CalibrationD 3249 Practice for General Ambient Air Analyzer Proce-duresD 3687 Practice for Analysis of Organic Compound VaporsCollected by the Activated Charcoal Tube AdsorptionMethod2.2 Other Standards:B
9、S 7860 Specification for Carbon Monoxide Detectors(Electrical) For Domestic Use3UL 2034 Single and Multiple Station Carbon MonoxideDetectors4CFR 1910.1450 Occupational Exposure to HazardousChemicals in Laboratories53. Terminology3.1 Definitions:For definitions of terms used in this guide, refer to T
10、ermi-nology D 1356.3.2 Definitions of Terms Specific to This Standard:3.2.1 air change ratethe volume of clean, humidified airplus contaminants that enters the chamber in 1 h, divided bythe internal volume of the chamber, expressed as air changesper hour (h1).3.2.2 chamberan enclosed test volume com
11、posed ofchemically inert materials supplied with a mixture of air, gases,or vapors, or combination thereof, having known composi-tions.1This guide is under the jurisdiction of ASTM Committee D22 on Sampling andAnalysis of Atmospheres and is the direct responsibility of Subcommittee D22.05on Indoor A
12、ir.Current edition approved January 1, 2005. Published January 2005. Originallyapproved in 1998. Last previous edition approved in 1999 as D 6332 - 99.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStan
13、dards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from British Standards Institute (BSI), 389 Chiswick High Rd.,London W4 4AL, UK4Available from Underwriters Laboratories (UL), Corporate Progress, 333Pfingsten Rd., Northbrook, IL 60062.5Available fr
14、om U.S. Government Printing Office Superintendent of Documents,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.3 CO alarm/detectoran alarm device consisting of anassemb
15、ly of electrical and mechanical components with chemi-cal, electrochemical, solid-state electronic, or other types ofsensors to detect the presence of CO gas in specified ranges ofconcentrations.3.2.4 sensorthe component included in the CO alarm/detector that senses CO gas.4. Summary of Guide4.1 Thi
16、s guide describes components of systems for testingCO detectors with mixtures of air and CO at different concen-trations of CO. The systems are also used for evaluating theresponses of CO detectors to mixtures of air and various gasesor vapors, or both. Such systems require clean air with apreselect
17、ed level of relative humidity supplied to an environ-mental chamber. Gases and vapors are introduced in the cleanair supply or placed directly in the chamber to achieve desiredchamber concentration. The components of such systemsinclude devices or modules for supplying pure air, humidifyingair, supp
18、lying gases or vapors, or both, to be tested, referenceinstruments for verifying concentrations of gases and vapors,and a chamber for placing and exposing CO detectors. Theguide describes various options for each component: chamber(Section 6), clean air supply module (Section 7), humidifica-tion mod
19、ule (Section 8), gas/vapor delivery module (Section9), and verification and control module (Section 10). The guidefurther provides recommendations on a minimum configura-tion for the testing system (Section 11) and reporting results(Section 12).5. Significance and Use5.1 This guide provides informat
20、ion on testing systems andtheir components used for measuring responses of CO alarmsor detectors subjected to gases, vapors, and their mixtures.Components of a testing system include a chamber, clean airsupply module, humidification module, gas and vapor deliverymodule, and verification and control
21、instrumentation.5.2 The CO detector is tested by sequential exposure to COand interference gases at the specified challenge concentra-tions. A properly functioning alarm/detector will sound uponsufficient exposure to CO but will not sound upon any exposureto interference gases consistent with applic
22、able standards (forexample, IAS 6-96 (1)6, BS 7860, UL 2034).6. Chamber6.1 Types of ChamberThere are two types of chambersstatic and dynamic. In a static chamber, air and knownquantities of gases are introduced and then the chamber issealed. In a dynamic chamber, a characterized air-gas mixtureis co
23、ntinually introduced at a rate sufficient to maintain targetconcentrations.6.2 HazardsIn a dynamic chamber, the air exiting cham-ber will contain CO and interference gases or vapors that maybe toxic. To avoid undue exposures of toxic gases and vaporsto occupants of the laboratory (where the chamber
24、is located),the chamber should be properly vented to outside with anappropriate stack. For a static chamber, exposures to test gasesshould be avoided in operating (for example, opening) thechamber.6.3 Size of the ChamberThe chamber size can be large(that is, room-size) or small and depends on the nu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD633219992005STANDARDGUIDEFORTESTINGSYSTEMSFORMEASURINGDYNAMICRESPONSESOFCARBONMONOXIDEDETECTORSTOGASESANDVAPORS

链接地址:http://www.mydoc123.com/p-522194.html