ASTM D5919-1996(2011) 9375 Standard Practice for Determination of Adsorptive Capacity of Activated Carbon by a Micro-Isotherm Technique for Adsorbates at ppb Concentrations《在ppb浓缩时.pdf
《ASTM D5919-1996(2011) 9375 Standard Practice for Determination of Adsorptive Capacity of Activated Carbon by a Micro-Isotherm Technique for Adsorbates at ppb Concentrations《在ppb浓缩时.pdf》由会员分享,可在线阅读,更多相关《ASTM D5919-1996(2011) 9375 Standard Practice for Determination of Adsorptive Capacity of Activated Carbon by a Micro-Isotherm Technique for Adsorbates at ppb Concentrations《在ppb浓缩时.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5919 96 (Reapproved 2011)Standard Practice forDetermination of Adsorptive Capacity of Activated Carbonby a Micro-Isotherm Technique for Adsorbates at ppbConcentrations1This standard is issued under the fixed designation D5919; the number immediately following the designation indicates
2、the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the assessment of activated
3、 carbonfor the removal of low concentrations of adsorbable constitu-ents from water and wastewater using the bottle point isothermtechnique. It can be used to characterize the adsorptiveproperties of virgin and reactivated activated carbons.1.2 This practice can be used in systems with constituentco
4、ncentrations in the low milligrams per litre or microgramsper litre concentration ranges.1.3 This practice can be used to determine the adsorptivecapacity of and Freundlich constants for volatile organiccompounds provided the handling procedures described in thispractice are followed carefully.1.4 T
5、he values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.5 The following safety caveat applies to the proceduresection of this practice: This standard does not purport toaddress all of the safety concerns, if any, associated with itsuse
6、. It is the responsibility of the user of this standard toestablish appropriate safety and health practices and deter-mine the applicability of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1129 Terminology Relating to WaterD1193 Specification for Reagent WaterD3370
7、 Practices for Sampling Water from Closed ConduitsD2652 Terminology Relating to Activated CarbonD2867 Test Methods for Moisture in Activated Carbon3. Terminology3.1 Definitions:3.1.1 For definitions of terms used in this practice relating toactivated carbon, refer to Terminology D2652.3.1.2 For defi
8、nitions of terms used in this practice relating towater, refer to Terminology D1129.4. Summary of Practice4.1 This practice consists of the determination of the ad-sorptive capacity of activated carbon for adsorbable constitu-ents by contacting the aqueous solution contained in anessentially zero he
9、ad space container with activated carbon,determining the amount of the constituents removed, andcalculating the adsorptive capacity and the Freundlich con-stants, K and 1/n, from a Freundlich isotherm plot.4.1.1 The weights of activated carbon used in this practicemay have to be adjusted to achieve
10、reasonable levels ofremoval of the constituent. The best data is obtained whencarbon dosages are selected that result in no more than 90 % orno less than 10 % of the adsorbable constituents being removedfrom the water by the carbon.4.1.2 If carbon dosages used are less than 1 mg, largervolumes of th
11、e aqueous solution may be used, such as 1000mL.5. Significance and Use5.1 This practice allows the adsorption capacity at equilib-rium of an activated carbon for adsorbable constituents presentin water to be determined. The Freundlich K and 1/n constantsthat can be calculated based upon information
12、collected usingthis practice can be used to estimate carbon loading capacitiesand usages rates for the constituent present in a water stream atother concentrations.6. Interferences6.1 The water shall not contain any nondissolved compo-nents.6.2 The presence of naturally occurring organic compoundssu
13、ch as humic acids in the water being studied may signifi-cantly affect the ability of the carbon to adsorb the constituent1This practice is under the jurisdiction of ASTM Committee D28 on ActivatedCarbon and is the direct responsibility of Subcommittee D28.02 on Liquid PhaseEvaluation.Current editio
14、n approved March 1, 2011. Published May 2011. Originallyapproved in 1996. Last previous edition approved in 2006 as D5919 96 (2006).DOI: 10.1520/D5919-96R11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of AS
15、TMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.of interest. Results obtained when using water other thanreagent grade water may be uniqu
16、e for the particular waterused and it may not be possible to apply these results to otherwater systems.6.3 The adsorption isotherm data collected using this prac-tice can be affected by the ionic strength, pH and temperatureof the water, and the presence and growth of microorganisms.7. Apparatus7.1
17、Equilibrator (or other rotating mixing device), a rotat-ing device operating at 25 rpm which can rotate the isothermbottles end over end ensuring good dispersion of the powderedactivated carbon in the water being treated.7.2 Grinding Mill, capable of grinding material so that 90 %passes through a U.
18、S. No. 325-mesh (45 m) sieve.7.3 Isotherm Bottles, narrow neck amber bottles with poly-tetrafluoroethylene (PTFE) coated septum sealed caps of 250,500, and 1000 mL capacity suitable for use in a centrifugeoperating at 2000 rpm.7.4 Solution Delivery Tank, a 10-L, 316 stainless steelcontainer equipped
19、 with a PTFE coated floating lid and a 316stainless ball valve to control flow during bottle filling.7.5 Analytical Balance, capable of weighing to the nearest0.1 mg.7.6 Oven, forced-air circulation, capable of temperatureregulation up to 250C.7.7 Centrifuge, capable of handling isotherm bottles up
20、to 1L in size at 2000 rpm.7.8 Magnetic Stirring Bars and Stirrers.8. Reagents8.1 Reagent Water, in accordance with Specification D1193,Type II.8.2 Methanol, high purity HPLC grade.8.3 Potassium Monobasic Phosphate (KHPO4), 1 M solu-tion.8.4 Sodium Hydroxide (NaOH), 1 M solution.9. Cleaning Procedure
21、s9.1 This practice is capable of generating activated carbonadsorption capacity data on aqueous solutions containing ppbw(g/L) levels of adsorbable constituents. It is therefore veryimportant that all equipment and glassware that come incontact with the activated carbon or the water being treated be
22、cleaned thoroughly to remove trace organic compounds.9.2 All equipment and glassware should first be rigorouslycleaned using procedures recommended by the EPAfor prioritypollutant analysis, hot water and detergent wash, reagent gradewater, and solvent (high purity methanol) rinse followed by abake-o
23、ut.9.3 The glassware is baked out in an oven at 250C for aminimum of one hour. All PTFE and stainless steel apparatusare dried at 110C for one hour.10. Preparation of the Activated Carbon10.1 This practice requires the use of well washed activatedcarbon that has been reduced in particle size so that
24、 90 % orgreater passes through a U.S. No. 325-mesh (45 m) sieve bywet screening or equivalent.10.2 Approximately 25 g of the powdered activated carbonsample is placed into each of four clean 250-mL bottles. Theremainder of the bottle is filled with reagent grade water.10.3 The bottle is tightly capp
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD5919199620119375STANDARDPRACTICEFORDETERMINATIONOFADSORPTIVECAPACITYOFACTIVATEDCARBONBYAMICROISOTHERMTECHNIQUEFORADSORBATESATPPBCONCENTRATIONS

链接地址:http://www.mydoc123.com/p-521054.html