ASTM D5708-2012 red 5000 Standard Test Methods for Determination of Nickel Vanadium and Iron in Crude Oils and Residual Fuels by Inductively Coupled Plasma (ICP) Atomic Emission Sp.pdf
《ASTM D5708-2012 red 5000 Standard Test Methods for Determination of Nickel Vanadium and Iron in Crude Oils and Residual Fuels by Inductively Coupled Plasma (ICP) Atomic Emission Sp.pdf》由会员分享,可在线阅读,更多相关《ASTM D5708-2012 red 5000 Standard Test Methods for Determination of Nickel Vanadium and Iron in Crude Oils and Residual Fuels by Inductively Coupled Plasma (ICP) Atomic Emission Sp.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5708 11D5708 12Standard Test Methods forDetermination of Nickel, Vanadium, and Iron in Crude Oilsand Residual Fuels by Inductively Coupled Plasma (ICP)Atomic Emission Spectrometry1This standard is issued under the fixed designation D5708; the number immediately following the designatio
2、n indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 These test methods cover the determ
3、ination of nickel, vanadium, and iron in crude oils and residual fuels by inductivelycoupled plasma (ICP) atomic emission spectrometry. Two different test methods are presented.1.2 Test Method A (Sections 7-11 and 18-22)ICPis used to analyze a sample dissolved in an organic solvent. This test method
4、uses oil-soluble metals for calibration and does not purport to quantitatively determine or detect insoluble particulates.1.3 Test Method B (Sections 12-22) ICP is used to analyze a sample that is decomposed with acid.1.4 The concentration ranges covered by these test methods are determined by the s
5、ensitivity of the instruments, the amountof sample taken for analysis, and the dilution volume.Aspecific statement is given in 15.2. Typically, the low concentration limitsare a few tenths of a mg/kg. Precision data are provided for the concentration ranges specified in Section 21.1.5 The values sta
6、ted in SI units are to be regarded as standard. The values given in parentheses are for information only.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and
7、 health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterD1548 Test Method for Vanadium in Heavy Fuel Oil1 (Withdrawn 1997)3D4057 Practice for Manual Sampling of Petroleum and Petroleum Pro
8、ductsD4177 Practice for Automatic Sampling of Petroleum and Petroleum ProductsD5185 Test Method for Determination of Additive Elements, Wear Metals, and Contaminants in Used Lubricating Oils andDetermination of Selected Elements in Base Oils by Inductively Coupled Plasma Atomic Emission Spectrometry
9、 (ICP-AES)D6299 Practice for Applying Statistical Quality Assurance and Control Charting Techniques to Evaluate Analytical Measure-ment System PerformanceD7260 Practice for Optimization, Calibration, and Validation of Inductively Coupled Plasma-Atomic Emission Spectrometry(ICP-AES) for Elemental Ana
10、lysis of Petroleum Products and Lubricants3. Summary of Test Method3.1 Test Method AApproximately 10 g of the sample are dissolved in an organic solvent (WarningCombustible. Vapor isharmful.) to give a specimen solution containing 10 % (m/m) of sample. The solution is nebulized into the plasma, and
11、theintensities of the emitted light at wavelengths characteristic of the analytes are measured sequentially or simultaneously. Theintensities are related to concentrations by the appropriate use of calibration data.1 These test methods are under the jurisdiction of ASTM Committee D02 on Petroleum Pr
12、oducts and Lubricants and is the direct responsibility of Subcommittee D02.03on Elemental Analysis.Current edition approved June 1, 2011Dec. 1, 2012. Published July 2011January 2013. Originally approved in 1995. Last previous edition approved in 20052011 asD570805.11. DOI: 10.1520/D5708-11.10.1520/D
13、5708-12.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 The last approved version of this historical standa
14、rd is referenced on www.astm.org.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recomm
15、ends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700
16、, West Conshohocken, PA 19428-2959. United States13.2 Test Method BOne to 20 g of sample are weighed into a beaker and decomposed with concentrated sulfuric acid(WarningPoison. Causes severe burns. Harmful or fatal if swallowed or inhaled.) by heating to dryness. Great care must be usedin this decom
17、position because the acid fumes are corrosive and the mixture is potentially flammable. The residual carbon is burnedoff by heating at 525C in a muffle furnace. The inorganic residue is digested with nitric acid(WarningPoison. Causes severeburns. Harmful or fatal if swallowed or inhaled.), evaporate
18、d to incipient dryness, dissolved in dilute nitric acid, and made up tovolume. The solution is nebulized into the plasma of an atomic emission spectrometer. The intensities of light emitted atcharacteristic wavelengths of the metals are measured sequentially or simultaneously. These intensities are
19、related toconcentrations by the appropriate use of calibration data.4. Significance and Use4.1 These test methods cover, in single procedures, the determination of Ni, V, and Fe in crude oils and residual oils. These testmethods complement Test Method D1548, which covers only the determination of va
20、nadium.4.2 When fuels are combusted, vanadium present in the fuel can form corrosive compounds. The value of crude oils can bedetermined, in part, by the concentrations of nickel, vanadium, and iron. Nickel and vanadium, present at trace levels in petroleumfractions, can deactivate catalysts during
21、processing. These test methods provide a means of determining the concentrations ofnickel, vanadium, and iron.5. Purity of Reagents5.1 Reagent grade chemicals shall be used in all tests. Unless otherwise indicated, it is intended that all reagents conform to thespecifications of the Committee onAnal
22、ytical Reagents of theAmerican Chemical Society where such specifications are available.4Other grades may be used, provided it is first ascertained that the reagent is of sufficiently high purity to permit its use withoutlessening the accuracy of the determination.5.2 When determining metals at conc
23、entrations less than 1 mg/kg, use ultra-pure reagents.5.3 Purity of WaterUnless otherwise indicated, reference to water shall be understood to mean reagent water conforming toType II of Specification D1193.6. Sampling and Sample Handling6.1 The objective of sampling is to obtain a sample for testing
24、 purposes that is representative of the entire quantity. Thus, takesamples in accordance with the instructions in Practice D4057 or D4177. Do not fill the sample container more than two-thirdsfull.6.2 Prior to weighing, stir the sample and manually shake the sample container. If the sample does not
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD57082012RED5000STANDARDTESTMETHODSFORDETERMINATIONOFNICKELVANADIUMANDIRONINCRUDEOILSANDRESIDUALFUELSBYINDUCTIVELYCOUPLEDPLASMAICPATOMICEMISSIONSPPDF

链接地址:http://www.mydoc123.com/p-520486.html