ASTM D4603-2003 Standard Test Method for Determining Inherent Viscosity of Poly(Ethylene Terephthalate) (PET) by Glass Capillary Viscometer《用玻璃毛细管粘度计测定聚对苯二甲酸乙二酯特性粘度的标准试验方法》.pdf
《ASTM D4603-2003 Standard Test Method for Determining Inherent Viscosity of Poly(Ethylene Terephthalate) (PET) by Glass Capillary Viscometer《用玻璃毛细管粘度计测定聚对苯二甲酸乙二酯特性粘度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4603-2003 Standard Test Method for Determining Inherent Viscosity of Poly(Ethylene Terephthalate) (PET) by Glass Capillary Viscometer《用玻璃毛细管粘度计测定聚对苯二甲酸乙二酯特性粘度的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4603 03Standard Test Method forDetermining Inherent Viscosity of Poly(EthyleneTerephthalate) (PET) by Glass Capillary Viscometer1This standard is issued under the fixed designation D 4603; the number immediately following the designation indicates the year oforiginal adoption or, in t
2、he case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method is for the determination of the inherentviscosity of poly(ethylene
3、 terephthalate) (PET) soluble at0.50 % concentration in a 60/40 phenol/1,1,2,2-tetrachloroethane solution by means of a glass capillary vis-cometer. Highly crystalline forms of PET that are not soluble inthis solvent mixture will require a different procedure.1.2 The inherent viscosity values obtain
4、ed by this testmethod are comparable with those obtained using differentialviscometry described in Test Method D 5225.1.3 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.4 This standard does not purport to address all of thes
5、afety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific hazardsstatements are given in Section 8.NOTE 1This test metho
6、d and ISO 1628-5 are similar but not techni-cally equivalent. This ISO standard gives an option of solvents for PET.Solvent specified in this ASTM test method is one of the options in theISO method. ISO also uses Type 1C Ubbelohde viscometer, rather than the1B, and reports viscosity number, rather t
7、han inherent viscosity.2. Referenced Documents2.1 ASTM Standards:D 445 Test Method for Kinematic Viscosity of Transparentand Opaque Liquids (and the Calculation of DynamicViscosity)2D 446 Specification for Operating Instructions for GlassCapillary Kinematic Viscometers2D 1972 Practice for Generic Ma
8、rking of Plastic Products3D 5225 Test Method for Measuring Solution Viscosity ofPolymers with a Differential Viscometer4E 1 Specification for ASTM Thermometers5E 380 Practice for Use of the International System of Units(SI)6E 691 Practice for Conducting an Interlaboratory Study toDetermine the Preci
9、sion of a Test Method62.2 ISO Standard:1628/51998 Determination of the Viscosity of Polymers inDilute Solution Using Capillary Viscometers - Part 5:Thermoplastic Polyester (TP) homopolymers and Copoly-mers.72.3 NIST Standard:C 602 Testing of Glass Volumetric Apparatus83. Terminology3.1 Units, symbol
10、s, and abbreviations used in this testmethod are those recommended in Practice E 380.3.2 Definitions of Terms Specific to This Standard:3.2.1 inherent viscosity (also known as the logarithmicviscosity number)defined by the equation given in 11.1.3.2.2 PETas outlined in Practice D 1972. The PET acro-
11、nym may be used to avoid trademark infringement and tocomply with various state or federal laws.4. Summary of Test Method4.1 The inherent viscosity is determined by measuring theflow time of a solution of known polymer concentration andthe flow time of the pure solvent in a capillary viscometer at a
12、fixed temperature. The inherent viscosity value is calculatedfrom the flow time values.1This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.70 on Analytical Methods(D20.70.05).Current edition approved March 10, 2003. Publis
13、hed April 2003. Originallyapproved in 1986. Last previous edition approved in 1996 as D 4603 96.2Annual Book of ASTM Standards, Vol 05.01.3Annual Book of ASTM Standards, Vol 08.01.4Annual Book of ASTM Standards, Vol 08.03.5Annual Book of ASTM Standards, Vol 14.03.6Annual Book of ASTM Standards, Vol
14、14.02.7Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.8Available from National Institute of Standards and Technology (NIST), 100Bureau Dr., Stop 3460, Gaithersburg, MD 20899-3460.1*A Summary of Changes section appears at the end of this stan
15、dard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5. Significance and Use5.1 The inherent viscosity is relatable to the compositionand molecular weight of a polyester resin. It must be controlledso that the processability and end p
16、roperties of the resin remainin a desired range.6. Apparatus6.1 Cannon Ubbelohde Type 1B Viscometer, as described inSpecifications and Operating Instructions D 446.6.2 Viscometer Holder.6.3 Electric Timer, readable to 0.1 s, as described in TestMethod D 445.6.4 Constant Temperature Bath, control lab
17、el at 30C86F 6 0.01C 0.02F.6.5 Kinematic Viscosity Thermometer ASTM 118 (for use at30C), conforming to Specification E 1.6.6 Temperature Controllable Magnetic Stirring Hot Plate.6.7 TFE-Fluorocarbon Plastic-Coated Stirring Bars and aMagnetic Bar Retriever.6.8 Volumetric Flasks and Stoppers, 50-mL ca
18、pacity, con-forming to the standards of accuracy in NIST Circular No.C 602.6.9 Analytical Balance, with readout to 0.0001 g.6.10 Borosilicate Funnels.6.11 Stainless Steel Filter Screening, 325-mesh or finer.6.12 Aspirator.6.13 Wiley Mill Grinder, with 20-mesh stainless steelscreen.6.14 Drying Oven,
19、for equipment.7. Reagents and Materials7.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Societywhere such specific
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD46032003STANDARDTESTMETHODFORDETERMININGINHERENTVISCOSITYOFPOLYETHYLENETEREPHTHALATEPETBYGLASSCAPILLARYVISCOMETER

链接地址:http://www.mydoc123.com/p-517479.html