ASTM D4245-2002 Standard Specification for Ozone-Resistant Thermoplastic Elastomer Insulation For Wire and Cable 90&176C Dry 75&176C Wet Operation《在干90℃ 湿75℃时电线和电缆的耐臭氧热塑性弹性体绝缘的标准规范.pdf
《ASTM D4245-2002 Standard Specification for Ozone-Resistant Thermoplastic Elastomer Insulation For Wire and Cable 90&176C Dry 75&176C Wet Operation《在干90℃ 湿75℃时电线和电缆的耐臭氧热塑性弹性体绝缘的标准规范.pdf》由会员分享,可在线阅读,更多相关《ASTM D4245-2002 Standard Specification for Ozone-Resistant Thermoplastic Elastomer Insulation For Wire and Cable 90&176C Dry 75&176C Wet Operation《在干90℃ 湿75℃时电线和电缆的耐臭氧热塑性弹性体绝缘的标准规范.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4245 02An American National StandardStandard Specification forOzone-Resistant Thermoplastic Elastomer Insulation ForWire and Cable, 90C Dry/75C Wet Operation1This standard is issued under the fixed designation D 4245; the number immediately following the designation indicates the year
2、 oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers an ozone-resistant insulating
3、compound for electrical wire and cables 14 AWG and larger.This compound consists substantially of a thermoplastic elas-tomer.1.2 This type of insulation is suitable for continuous opera-tion at conductor temperatures not exceeding 90C in drylocations and 75C in wet locations. Operating voltages are
4、notto exceed 2000 V. The minimum installation temperatureis 40C.1.3 Whenever two sets of values are presented, in differentunits, the values in the first set are the standard, while those inparentheses are for information only.1.4 In many instances the insulation material cannot betested unless it h
5、as been formed around a conductor or cable.Therefore, tests are done on insulated wire or cable in thisdocument solely to determine the relevant property of theinsulation material and not to test the conductor or completedcable.2. Referenced Documents2.1 ASTM Standards:D 470 Test Methods for Crossli
6、nked Insulations and Jacketsfor Wire and Cable2D 1711 Terminology Relating to Electrical Insulation2D 2633 Methods of Testing Thermoplastic Insulations andJackets for Wire and Cable33. Terminology3.1 Definitions: For definitions of terms used in this speci-fication refer to Terminology D 1711.3.2 De
7、finitions of Terms Specific to This Standard:3.2.1 aging, nexposure of materials to air at 121C for168 h.4. Physical Properties4.1 Requirements for physical properties are listed in Table1.4.2 Thickness of InsulationTable 1(a) (Conductor Sizes,Insulation Thicknesses, and AC Test Voltages for RubberI
8、nsulations) of Test Methods D 470 lists the minimum averagethickness for the insulation. The required minimum thicknessis 90 % of the specified average thickness.5. Electrical Requirements5.1 Order of TestingPerform the ac voltage test, insulationresistance, and dc voltage tests in that order when a
9、ny of thesetests are specified. The sequence of other testing is notspecified.5.2 AC Voltage TestUnless otherwise specified, omit thistest if the dc voltage test described in 5.4 is to be performed.Test each insulated conductor for 5 min at the ac withstandvoltage given in Table 1(a) (Conductor Size
10、s, InsulationThicknesses, and AC Test Voltages for Rubber Insulations) ofTest Methods D 470 under the columns labelled “Ozone-Resisting Insulation.”5.3 Insulation Resistance5.3.1 The insulated conductor shall have an insulationresistance value of at least that corresponding to a constant of10 000 at
11、 60F (15.6C).5.3.2 If the water temperature at the time measurement wasmade differs from 60F (15.6C), correct the insulation resis-tance to 60F. Table 2, (Temperature Correction Factors forInsulation Resistance at 60F), of Test Methods D 470, con-tains the correction factors. Each insulation manufac
12、turer canfurnish the 1F coefficient for the insulation material by usingthe procedure given in Test Methods D 470. Multiply themeasured value by the correction factor to obtain the insulationresistance value corrected to 60F.5.3.3 If the insulated conductor is covered with a non-metallic sheath so t
13、hat the insulation resistance can be mea-sured only on the completed assembly, the required insulationresistance shall be not less than 60 % of that required for theprimary insulation based on the thickness of that insulation.5.4 DC Voltage TestUnless otherwise specified, omit thistest if the ac vol
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD42452002STANDARDSPECIFICATIONFOROZONERESISTANTTHERMOPLASTICELASTOMERINSULATIONFORWIREANDCABLE90176CDRY75176CWETOPERATION

链接地址:http://www.mydoc123.com/p-516626.html